background image

A-100

Standard Photoelectric Sensors

Precautions

Mounting Directions

Sensor assembly

Contrary to sensors with single triangulation, E3NT with dou-

ble triangulation, allows the measured object's direction of

motion to be in all three directions. Thus, the rotatory position

of the sensor about its optical axis can be chosen freely. 

If the light spot is not completely on the same plane as the tar-

get object (minimum object size) the distance is not deter-

mined and malfunction can occur. If necessary a trigger signal

or timer function has to be applied.

The sensor must be fitted so that:

• It is correctly aligned before it is adjusted

• It is protected as far as possible against vibration and shock

• It is protected as far as possible against extraneous incident

light

• It is protected as far as possible against damage and soiling

• Electrical connection is possible

• It is as accessible as far as possible for maintenance work

• Operation of the push buttons is possible

• The display is visible.

Sensor's assembly direction

As far as possible, the sensor's optical surface should be

aligned parallel to the surface of the measured object.

If the measured object has a glossy, reflecting surface, the

sensor's optical system should be tilted by 5 … 10° in relation

to the surface of the measured object.

If there is a reflecting surface in parallel with the sensor's op-

tical axis, this might lead to unstable switching states.

Therefore, reflecting objects within the sensor's optical axis

should be avoided.

If this should not be possible, the reflecting surface should not

be parallel to the sensor's optical axis, but should be rotated

by at least 10°.

Mirror-like objects can cause malfunction inside and outside

the sensing range. Avoid mirror-like objects in or close to the

optical axis.

Inspection and Maintenance

Cleaning

Do not use any scratching or abrasive cleaning materials. The

protective pane of the optical system might get damaged.

The sensor requires no maintenance.

Remove dirt build up from the optical system and the display

at regular intervals only with a soft, non abrasive fabric. Re-

sidual dirt may have influence on the switching point and dis-

play accuracy.

90˚

90˚

detection object

90˚

5 … 10˚

˚

detection object

In the interest of product improvement, specifications are subject to change without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. 

E332-E2-02

-X

F502-EN2-04.book  Seite 100  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for E3NT -

Page 1: ...models with sensing distance up to 16 m Two programmable outputs for win dow teaching Double triangulation for stable detec tion of reflective objects IP67 and IP69k for highest resistance in wet envi...

Page 2: ...sion E3NT L17 20 E3NT L37 20 Window heating 0 2 m 2 0 m E3NT LH17 E3NT LH37 Fast response E3NT L17 E3NT L37 Analog and digital output E3NT L27 E3NT L47 Retro reflective with MSR polarisa tion Long dis...

Page 3: ...E39 EL3 1 Adapter bracket replacing E3N with E3NT f for M3 for M3 9 100 100 92 92 Size Cable type Shape Cable length Model M12 Standard 5 pole 2m XS2F D521 DG0 A 5m XS2F D521 GG0 A 2m XS2F D522 DG0 A...

Page 4: ...f setting distance Sr or 6 cm for black 6 10 of setting distance Sr or 10 cm for white 15 of setting distance Sr or 10 cm for black Repetition accuracy 5 of setting distance Sr or 4 cm 5 of setting di...

Page 5: ...silicone Housing color Grey RAL 7030 Assembly Screw fastening by way of four M5 threads and two M5 through holes or with universal mounting bracket order separately Connection M12 connector 5 pole pi...

Page 6: ...age Via RS 232 interface from PC Current consumption 6 mA Item Supply voltage 3 V DC Battery type Button battery 11 6 mm thickness 5 4 mm 3 Vm type CR1 3N Ambient temperature range 10 C 40 C Storage t...

Page 7: ...000 1500 2000 2500 Object position X mm Distance Z mm E3NT X Z Object 10 5 0 5 10 15 20 0 500 1000 1500 2000 2500 Black White error Distance Z mm E3NT X Z Object 0 5 10 15 0 500 1000 1500 2000 2500 Hy...

Page 8: ...nectors Push pull output circuit Out1 at pin 4 Out2 at pin 2 Load connection PNP NPN Analog In2 at pin 2 In1 at pin 5 not available for analogue output models Class Wire jacket color Connector pin no...

Page 9: ...nsor switches from the normal mode to the TEACH menu path The sensor switches to each next menu path when the EN TER key is repeatedly pressed for 2 seconds In the menu paths the required parameters c...

Page 10: ...ached tch Output 1 Switch point A set Ad b Output 1 Switch point B set Teaching Switching point A Output 1 Teaching Switching point B 1 Output 1 Teaching Switching point C Output 2 2 Teaching Switchin...

Page 11: ...t2 Select function with b65 Background suppression F65 Foreground suppression 2 P Window evaluation Select function with L on light on d on dark on 0ut1 Select function with b65 Background suppression...

Page 12: ...delay Single pulse ti 2 Select function with ff Switch on switch off delay OFF n 1 Switch on switch off delay NORMAL n 2 Switch off delay Minimum pulse width n 3 Switch off delay Single pulse flip 0pt...

Page 13: ...unction in OPT menu Switch on delay of switching output in ms regarding to setting of delay function in OPT menu minimum pulse width constant pulse width of switching output in ms regarding to setting...

Page 14: ...constant pulse width Enter ECO mode OFF ECO mode ON Comple mentary Enter Menu items Function connector pin 2 Function connector pin 5 Switching output delay functions Energy saving mode ECO Turn displ...

Page 15: ...E3NT L17 E3NT L27 E3NT LH17 E3NT L37 E3NT L47 E3NT LH37 14 33 4 14 27 M12 14 3 88 7 30 23 1 15 7 4 7 65 1 M5 2x M5 4x 12 1 23 1 30 65 1 15 2 4 7 M12 14 33 4 14 27 88 7 M5 2x M5 4x Optical data link E3...

Page 16: ...2 0 1 15 R 30 74 10 7 R 25 10 5 9 5 28 R 8 2 7 4 10 55 5 92 4 90 4 2 0 1 Rx 60 120 1 38 1 R30 30 84 5 26 25 R 8 0 6 2 10 7 7 5 3 0 1 14 2 5 46 50 11 R x 2 5 17 5 28 8 5 30 R 22 5 R28 4 15 39 5 31 108...

Page 17: ...A 99 E3NT E3NT Replacement bracket for E3N with E3NT E39 EL3 3 50 73 90 70 R6 4x R2 4 x 6 5 6 12 14 0 3 12 x 5 2 14 0 3 1 0 30 58 10 21 30 7 10 35 15 6 5 R60 material stainless steel 1 4305...

Page 18: ...he measured object has a glossy reflecting surface the sensor s optical system should be tilted by 5 10 in relation to the surface of the measured object If there is a reflecting surface in parallel w...

Reviews: