background image

2

Standard Photoelectric Sensors

Specifications

Ratings / Characteristics

Item

E3F2-3Z1
E3F2-3Z2

E3F2-R2Z1
E3F2-R2Z2

E3F2-DS10Z1
E3F2-DS10Z2

Type

Through-beam

Retro-reflective without M.S.R.

Diffuse-reflective (wide-beam)

Power supply voltage

24 to 240 VAC ±10 %, 50 / 60 Hz

Current consumption

10 mA max.

5 mA max.

Sensing distance

*1

*1.

For sensing distance in detail, please refer to ”Engineering Data”

3 m 

0.1 to 2 m
(with E39-R1)

0.1 m 
(5 x 5 cm white mat paper)

Detectable object

Opaque object: 11 mm min.

Opaque object: 56 mm min.

Opaque objects

Directional angle

3° to 20°

Differential travel

20 % max.

Response time

30 ms max.

Control output

AC solid state (SCR) 200 mA max.; residual voltage: 5 V max. at 200 mA

Power reset time

100 ms

Ambient illumination 

Incandescent lamp: 3000 lx max. Sunlight: 10000 lx max.

Ambient temperature

Operating: -25 to 55 °C / Storage: -30 to 70 °C (with no icing or condensation)

Ambient humidity

Operating: 35% to 85% / Storage: 35% to 95% (with no condensation)

Insulation resistance

20 M

Ω

 min. at 500 V DC between energized parts and case

Dielectric strength

1500 VAC, 50 / 60 Hz for 1 min between energized parts and case

Vibration resistance

10 to 55 Hz, 1.5 mm double amplitude for 2 hrs each direction (X, Y, Z)

Shock resistance

500 m/sqr (approx. 50 g) for each direction (X, Y, Z)

Degree of protection

IEC 60529: IP66

Light source (wave length)

Infrared LED (880 nm)

Indicators

Light incident/power indicator for light source (red)

Sensitivity adjustment

Fixed

Connection method

2 m, 5 m pre-wired cable (PVC dia. 4 mm (14 / 0.15) 

*2

)

*2.

For other cable materials (e.g. PUR) please contact your OMRON sales representative.

Operation mode

Light-ON or Dark-ON (fixed)

Circuit protection

None

Weight (approx.)

110 g (pre-wired 2 m cable)

Housing materials

Plastic (case: ABS; lens: PMMA)

Summary of Contents for E3F2-240VAC

Page 1: ...length please contact your OMRON sales representative Accessories Order Separately For detailed information about Accessories refer to the main chapter Accessories at the end of the document Sensing...

Page 2: ...light 10000 lx max Ambient temperature Operating 25 to 55 C Storage 30 to 70 C with no icing or condensation Ambient humidity Operating 35 to 85 Storage 35 to 95 with no condensation Insulation resist...

Page 3: ...300 Distance Y mm Distance X m typical sensing distance 3 8 m X Y 1 2 3 4 5 6 0 0 100 200 300 100 200 300 Distance Y mm Distance X m 8 7 typical sensing distances E39 R1 3 4 m E39 R7 3 9 m E39 R8 5 2...

Page 4: ...Light ON E3F2 3Z2 E3F2 R2Z2 E3F2 DS10Z2 N ON when light is interrupted Dark ON Main circuit 24 to 240 VAC Brown Blue Power indicator red Incident Interrupted ON OFF ON OFF Operate Release Output indic...

Page 5: ...R2Z E3F2 DS10Z N Reflectors Installation E39 R1 E39 R1S E39 R8 E39 R7 16 8 dia 24 3 1 optical zone 22 90 67 3 62 M18 x 1 6g 5 dia 8 3 1 Light indicator Material reflective surface acrylic Rear surface...

Page 6: ...ct to direct sunlight Cleaning Do not use thinner alcohol or other organic solvents Otherwise the optical properties and degree of protection may be degraded Surface Temperature Burn injury may occur...

Page 7: ...7 E3F2 240VAC...

Page 8: ...isted may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy contro...

Reviews: