background image

D-61

E2S

E2S

Miniature Square Inductive Proximity Sensor

E2S

• Miniature housing with long sensing ranges

• Front ans side facing sensing surfaces

Features

The 5.5 mm x 5.5 mm type permits smaller, space-saving ma-

chines and devices.

Full sealing structure housing, degree of protection IEC60529 IP67.

Significantly lower current consumption. The 0.8 mA (for 24

VDC) leakage current for the DC 2-wire type has a ratio of ap-

proximately 1/20 compared to the conventional DC 3-wire

type. Optimum solution for multiple-sensor applications such

as cam switches.

5.5 mm

Adopted for more compact machines and devices.

5.5mm

1 kHz

IP67

1/20

Ultra small housing

High-Speed Response

Environment-Resistant Types

Low Current Consumption (Com-
pared to conventional models)

F502-EN2-04.book  Seite 61  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for E2S

Page 1: ...otection IEC60529 IP67 Significantly lower current consumption The 0 8 mA for 24 VDC leakage current for the DC 2 wire type has a ratio of ap proximately 1 20 compared to the conventional DC 3 wire type Optimum solution for multiple sensor applications such as cam switches 5 5 mm Adopted for more compact machines and devices 5 5mm 1 kHz IP67 1 20 Ultra small housing High Speed Response Environment...

Page 2: ...ions Model Operating status NO NC Front face NPN E2S W13 E2S W14 End face E2S Q13 E2S Q14 Front face E2S W23 E2S W24 End face E2S Q23 E2S Q24 Front face PNP E2S W15 E2S W16 End face E2S Q15 E2S Q16 Front face E2S W25 E2S W26 End face E2S Q25 E2S Q26 Shape Model Quantity Remarks Y92E C1R6 1 Provided with E2S 1 Y92E C2R5 Provided with E2S 2 Y92E D1R6 Y92E D2R5 Unshielded 1 6mm 2 5mm Unshielded 1 6mm...

Page 3: ...ching capacity 3 to 50 mA DC max Residual voltage 3 V max under load current of 50 mA with cable length of 1 m Indicator lamp 1 models Operation indicator red LED Operation set indicator green LED 2 models Operation indicator red LED Operating status with sensing object approaching 1 models NO 2 models NC Model E2S W13 E2S W14 E2S Q13 E2S Q14 E2S W23 E2S W24 E2S Q23 E2S Q24 E2S W15 E2S W16 E2S Q15...

Page 4: ...tween energized parts and case Dielectric strength 1 000 VAC for 1 min between energized parts and case Vibration resistance 10 to 55 Hz 1 5 mm double amplitude for 2 hours each in X Y and Z directions Shock resistance Destruction 500 m s2 for 3 times each in X Y and Z directions Protective structure IEC60529 IP67 Connection method Pre wired models Standard length 3 m Weight Packed state Approx 10...

Page 5: ...Sensor ON OFF ON OFF ON OFF Setting indicator green Operation indicator red Control output Load Brown Blue Main circuit V 0V 100 0 Sensing object Sensing zone Non sensing zone Non sensing zone Proximity Sensor ON OFF ON OFF Operation indicator red Control output Yes No ON OFF ON OFF Sensing object Operation indicator orange Output transistor load Load Brown Black Output Blue Main circuit V 0V Maxi...

Page 6: ...adjacent Sensors to suppress mutual interference as provided in the following diagram Unit mm Note The above values in parentheses are applicable when using two sensors with different frequencies Mounting Tightening torgues Do not tighten the E2S W Q 2 mounting screws to a torque exceeding 0 7 Nm Correct Use Model Length A B C E2S W1 0 8 2 E2S W2 15 10 Model Length A B C E2S Q1 8 3 2 E2S Q2 15 10 ...

Page 7: ...conductor sectional area 0 14mm2 Insulator diameter 0 9 dia standard length 1 m 7 4 7 8 2 3 11 3 20 3 10 8 2 5 2 2 3 1 dia If mounting bracket is attached E2S Q2 If mounting bracket is attached 8 8 4 8 2 3 8 9 14 5 3 6 4 1 18 5 11 3 23 3 Sensing surface Indicator 2 9 dia vinyl insulated round cable 2 3 cores conductor sectional area 0 14m u Insulator diameter 0 9 dia standard length 1 m 10 8 3 1 d...

Page 8: ... of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No E902 E2 02 X ...

Reviews: