Rating and Specifications

DC 2-Wire (E2FM-X

@

D

@

)

* The response frequency of the DC switching section is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the 

standard sensing object, and a set distance of half the sensing distance.

Size

M8

M12

M18

M30

M12

M18

M30

Shielded

Shielded

Item

Model

E2FM-X1R5D1

-M1GJ

E2FM-X2D1

-M1GJ

E2FM-X5D1

-M1GJ

E2FM-X10D1

-M1GJ

E2FM-X2D1

-M1GJ-T

E2FM-X5D1

-M1GJ-T

E2FM-X10D1

-M1GJ-T

Sensing distance

1.5 mm±10%

2 mm±10%

5 mm±10%

10 mm±10%

2 mm±10%

5 mm±10%

10 mm±10%

Set distance

0 to 1.05 mm

0 to 1.4 mm

0 to 3.5 mm

0 to 7 mm

0 to 1.4 mm

0 to 3.5 mm

0 to 7 mm

Differential travel

15% max. of sensing distance

Sensing object

Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to 

Engineering Data

 on page 5.)

Standard sensing 
object

Iron, 

×

 8 

×

 1 mm

Iron, 
12 

×

 12 

×

 1 

mm

Iron, 
30 

×

 30 

×

 1 

mm

Iron, 
54 

×

 54 

×

 1 

mm

Iron, 
12 

×

 12 

×

 1 

mm

Iron, 
30 

×

 30 

×

 1 

mm

Iron, 
54 

×

 54 

×

 1 

mm

Response frequency * 200 Hz

100 Hz

100 Hz

50 Hz

100 Hz

100 Hz

50 Hz

Power supply voltage
(operating voltage 
range)

12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Leakage current

0.8 mA max.

Output configuration

With polarity

Without polarity

Control 
output

Switching 
capacity

3 to 100 mA

Residual
voltage

3 V max. 
(Load current: 100 mA, Cable length: 2 m)

5 V max. 
(Load current: 100 mA, Cable length: 2 m)

Indicators

Operation indicator (red LED), Setting/Operation indicator (green LED)

Operation mode
(with sensing object 
approaching)

NO

Protection circuits

Surge suppressor, Load short-circuit protection

Ambient temperature 
range

Operating/Storage: -25 to 70

°

C (with no icing or condensation)

Ambient humidity 
range

Operating/Storage: 35% to 95% (with no condensation)

Temperature 
influence

±20% max. of sensing distance at 23

°

C in the temperature range of -25 to 70

°

C.

Voltage influence

±1% max. of sensing distance at rated voltage in the rated voltage ±15% range

Insulation resistance

50 M

Ω

 min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 
500 m/s

2

10 times each 
in X, Y, and Z 
directions

Destruction: 1,000 m/s

2

 10 times each in X, Y, and Z directions

Degree of protection

IEC 60529 IP67, DIN 40050 part 9: IP69k

Connection method

Pig-tail Connector Models (Standard cable length: 0.3 m)

Weight (packed state)

Approx. 65 g

Approx. 85 g

Approx. 110 g Approx. 190 g Approx. 85 g

Approx. 110 g Approx. 190 g

Materi-
als

Case

Stainless steel (SUS303)

Sensing 
surface

Stainless steel (SUS303)

(thickness)

(0.4 mm)

(0.8 mm)

(0.8 mm)

Clamping
nuts

Stainless steel (SUS303)

Cable

PVC (flame retardant)

Toothed
washer

Zinc-plated iron

Accessories

Instruction manual

Summary of Contents for E2FM -

Page 1: ...ge Application Full body stainless steel housing with 0 8 mm thick sensing face protection 0 8 mm The stainless steel head shows minimal wear when cleaned with a metal brush More than 20 times the durability of standard sensors Brush Test E2FM Standard sensor Continuous Impact Test Standard sensor E2FM The standard sensor with top wall thickness of 0 2 mm was pene trated after 10 000 impacts The E...

Page 2: ...FM X2D1 M1GJ No polarity No Pin allocations 3 4 E2FM X2D1 M1GJ T M18 Polarity Yes Pin allocations 1 4 E2FM X5D1 M1GJ No polarity No Pin allocations 3 4 E2FM X5D1 M1GJ T M30 Polarity Yes Pin allocations 1 4 E2FM X10D1 M1GJ No polarity No Pin allocations 3 4 E2FM X10D1 M1GJ T Appearance Sensing distance Output configuration Operation mode Model Shielded M8 DC 3 Wire PNP NO E2FM X1R5B1 M1 M12 E2FM X2...

Page 3: ...m 5 V max Load current 100 mA Cable length 2 m Indicators Operation indicator red LED Setting Operation indicator green LED Operation mode with sensing object approaching NO Protection circuits Surge suppressor Load short circuit protection Ambient temperature range Operating Storage 25 to 70 C with no icing or condensation Ambient humidity range Operating Storage 35 to 95 with no condensation Tem...

Page 4: ...hing NO Protection circuits Reversed power supply polarity protection Surge suppressor Load short circuit protection and Reversed out put polarity protection except the E2FM X1R5B1 M1 Ambient temperature range Operating Storage 25 to 70 C with no icing or condensation Ambient humidity range Operating Storage 35 to 95 with no condensation Temperature influence 20 max of sensing distance at 23 C in ...

Page 5: ...Aluminum Brass Copper Stainless steel SUS304 Side length of sensing object d mm 7 6 5 4 3 2 1 0 0 20 40 60 80 Distance X mm Stainless steel SUS304 Iron Brass Aluminum Copper Side length of sensing object d mm 12 10 8 6 4 2 0 0 10 20 30 40 50 60 80 90 70 Distance X mm Side length of sensing object d mm Stainless steel SUS304 Iron Brass Aluminum Copper E2FM X1R5D1 M1GJ 1 0 0 8 0 6 0 4 0 2 0 0 0 5 10...

Page 6: ...d to either the V or 0 V side Load 12 to 24 VDC Connector Pin Arrangement Note Pins 2 and 3 are not used 4 3 Proximity sensor main circuit 12 to 24 VDC Load Connector Pin Arrangement Note Pins 1 and 2 are not used 0 V 12 to 24 VDC Note 1 The load can be connected to either the V or 0 V side 2 The E2FM X 1 M1GJ T has no polarity There is no need to be concerned about the polarity of pins 3 and 4 10...

Page 7: ...uction Wire the Sensor using a separate conduit or independent conduit 4 Cleaning Never use thinner or other solvents Otherwise the Sensor surface may be dissolved Design Influence of Surrounding Metal When the Proximity Sensor is embedded in metal make sure that the clearances given in the following table are main tained The values depend on the type of nuts used for mount ing Be sure to use the ...

Page 8: ...00 mm 2 Operation indicator red green Setting indicator green E2FM X5D1 M1GJ E2FM X5D1 M1GJ T 36 63 5 49 43 5 10 M30 1 5 42 dia Toothed washer Two clamping nuts Indicator 2 1 M12 1 1 6 dia vinyl insulated round cable flame retardant Standard length 300 mm 2 Operation indicator red green Setting indicator green E2FM X10D1 M1GJ E2FM X10D1 M1GJ T 4 5 13 25 30 34 5 53 5 15 dia Two clamping nuts Toothe...

Page 9: ...isted may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations S...

Page 10: ... the interest of product improvement specifications are subject to change without notice Cat No D104 E2 01 X OMRON EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorp The Netherlands Phone 31 23 568 13 00 Fax 31 23 568 13 88 www eu omron com ...

Reviews: