background image

RUN

SET

Teaching

(Detection levels/Threshold display)

NO(normally-open)

NO

NC

NC(normally-close)

Single edge
Either the rising or falling 
edge is detected.
Double edge
Both the rising and falling 
edge are detected.

Detection level

Threshold value

Threshold value

The detection level 
and threshold value

Timer disabled

----

OFFD

OFF-delay timer

ON-D

ON-delay timer

1SHT

One-shot timer

300μs

500μs

500μs

1ms

1ms

2ms

10ms

20ms

100ms

200ms

Single edge

This setting depends on the setting 
for the differential edge selection.

Switch to SET mode.

Setting range: 1 to 5,000

Double edge

Standard mode
Response time: 1 ms

STND

HRES

High-resolution mode
Response time: 4 mss

DIFF

Not

SHS

Super-high-speed mode

Response time: 150μs

High-speed mode
Response time: 300μs

HS

Set separately for each channel for Twin-output Models.

2. Timer

5. Mode Key

    Setting

6. Display Switch

7. Display

    Orientation

9. Hysteresis Setup

10. External Input

      Memory

4. External Input

3. Twin Outputs

8. Mutual Interference

    Prevention

    Number Set up

% detection level

O-PE

C-BT

PEAK

BOTM

Detection status

Peak level

Bottom level

The following functions can be set in SET mode. The default settings are shown in the transition boxes 
between functions.
For Twin-output Models, all settings except for the operation mode, timer settings and hysteresis setting 
are the same for both channels.
*: The values shown for thresholds, detection levels, percentages, etc., are examples only. Actual 
displays may vary.

The item that is controlled by the input from an external 

device can be selected.

Normal display

D123

321D

Reversed display

Write results to EEPROM.

ON

OFF

Do not write results to EEPROM.

NEAR

Positioning teaching

PPT

No-workpiece teaching

2PNT

Teaching with and without a  workpiece

Effective Pulse Widths

FP

Fine positioning

0RST

Zero reset

0.1s to 2s

Executing: 0.1 to 2s
Clearing: 3s or longer

Effective ON pulse 
width: 0.1s min.
Detection response 
time 500

μ

s min.

Selection

Pulse width

SYNC

Synchronous detection

The function is detected only while 

the input is ON.

Executes a fine positioning

FP

0RST

Executes a teaching with and 
without a workpiece

2PNT

Executes a positioning teaching

PPT

Executes a zero reset

The function of the MODE key in RUN mode can be 

selected.

Output for each channel.

2OUT

AREA

Output if level is between the two 
thresholds.

SELF

HEAD

(Twin-output Models Only)

(External-input Models Only)

Mutual interference prevention does 
not work.

OFF

(External-input Models Only)

Detection level

Channel

The detection level and 
channel number

The output for channel 1 functions according to the 

detection mode selection.

,

,

Detection level

Detection level

PEAK

Peak level

Display alternates 

at a fixed interval.

Display alternates 

at a fixed interval.

A

B

C

A

B

C

Switch to RUN mode. 

Switch to RUN mode.

RUN

SET

6. Convenient Functions

Initializing Settings

RUN

SET

RUN

SET

Initialization has been 
completed.

Key Lock

NO?

YES?

Switch to SET mode.

LOC

ON

LOC

OFF

INIT

INIT

GOOD

Hock on the Sensor Head connector end

DIN Track

DIN Track

1

2

1

1

2

1

2

(Unit: mm)

E2C-EDA11 and E2C-EDA6(NPN Models)

E2C-EDA41 and E2C-EDA8(PNP Models)

E2C-EDA21 and E2C-EDA7(NPN Models)

E2C-EDA51 and E2C-EDA9(PNP Models)

2.5

50.3

76

24.7

9.9

3.4

32

36.7

14

32

8.1

10

13.8

38.8

18.15

21.1

35.8

3.9×4=11.7

3.9×4=11.7

(Prewired Models)

The number of the amplifier which confirms mutual 

interference prevention is set up.

Only the amplifier which wants to confirm mutual 

interference prevention is made to connect, and it is 

set as all amplifier.

After a setup should surely re-switch on a power supply.

The number of a setting: 2

2UT

 to 5

5UT

5. Detailed Settings

AUTO

All key operations can be disabled to help prevent key operating errors.
Only the operation keys are disabled. The switches and selectors will still function.

This procedure can be used to return all the settings to the original default values.

Setting Method

Setting Method

Clearing Method

Mounting Units

Catch the hook on the Sensor Head connector end 
of the Unit on the DIN Track and then press down 
on the other end of the Unit until it locks into place.

Always attach the Sensor Head connector end first. 
If the incorrect end is attached first, the mounting
strength will be reduced.

Removing Units

Press the Unit in the direction indicated by "1" 
and then lift up on the Sensor Head connector 
end of the Unit in the direction indicated by "2"

Mounting Amplifier Units in Group (Connector Type Models/Communication Unit 
Connection Type Models)

Up to 16 connector type models can be connected. Up to 30 communication unit
connection type models can be connected to the communication unit
E3X-ECT, or 16 units to the E3X-CRT.
1. Mount the Amplifier Units one at a time onto the DIN Track.
2. Slide the Amplifier Units together and press the Amplifier 
    Units together until they click into place.

Secure the Units with an End Plate (PFP-M) if there is a 
possibility of the Amplifier Units moving, e.g., due to vibration.

Reverse the above procedure to separate and remove the 
Units. Do not attempt to remove Amplifier Units from the 
DIN Track without separating them first.

7. Installing the Amplifier Unit

9. I/O Circuits 

10. Dimensions

Lock button

     1. Open the protective cover
     2. A connector is turned so that a lock button may turn up, 
         and it inserts to the back.

To disconnect the Sensor Head, pull out the connector 
while pressing on the lock button.

8. Connecting Sensor Heads

Display alternates 

at a fixed interval.

Twin-output models can be set up for every channel.

Note: Refer to 

4. Basic Settings for teaching methods.

Set separately for each channel.

0. Operation Mode

1. Detection Method

Differential

Edge Selection

Differential

Response Time

(Twin-output Models only)

Differential operation mode 

Operation is according to the change 

in the detection level.

For Twin-output Models, the output for 

channel 2 is always an alarm output 

for the absolute detection level.

Not

Timer Time

1-ms increments

1 to 20 ms

5-ms increments

20 to 200 ms

100-ms increments

200 ms to 1 s

1-s increments

1 to 5 s

The function of the output for channel 2 can be selected.
This setting is not value if DIFF (differential operation) 
is set for the detection method. (The output for channel
2 is always an alarm output for differential operation.)

Self-diagnosis output

Output when the detection level 

is not stable, i.e., when the detection 

level is ±10% of the threshold value 

for 300 ms or longer.
Disconnection output

A disconnection output is outputted, 

when the Sensor Head is 

disconnected, or it does not connect.

Automatic teaching

The maximum and minimum detection

 levels are sampled while the input is ON and, 

when the input turns OFF, the average of these 

values is set as the threshold value.

Disabled if the detection function is set to 

"DIFF" (differential operation).

The information displayed in RUN mode can be selected. 
When going to SET mode, this setting will be ignored and 
the detection level and threshold value will be displayed.

The detection level as 

a percentage of the 

threshold value and the 

threshold value.
The peak detection 
level and bottom 
detection level of fixed 
time(2s).

The peak detection level 

under detection, and the 

bottom detection level in 

un-detecting.

A display is updated when 

detection-un-detecting 

changes.
Analog bar display. The 

current detection status is 

displayed as an analog 

bar. The bar will lengthen 

from the right as ON 

status is reached.

The current detection 
level and the peak 
detection level. 

Hysteresis is set up.
Hysteresis is adjusted to perform the case where 
the position of a workpiece is unstable, and finer 
detection.
Adjustment range: 10 to 2000

Whether external input execution results are written 
to EEPROM can be selected.
Disable this function if the external input is turned 
ON frequently. (The write life is approximately 100,000 
writes.)

Hold down the MODE key and 
press the UP key for at least 3 
seconds. Press the UP key right 
after pressing the MODE key. 

Hold down the MODE key 
and press the UP key for at 
least 3 seconds. Press the 
UP key right after pressing 
the MODE key.

The sub-display will 
flash twice and key 
input will be disabled.

The sub-display will 
flash twice and key 
input will be enabled.

If a key is pressed while key operations are locked, "LOC" will flash 
twice on the display to indicate that key operations have been disabled.

Press the UP or 
DOWN key for at 
least 3 seconds.

Press the MODE key at the 
"NO?" or "YES?" display.

Settings not initialized.

Settings initialized.

Int

er

nal cir

cuits

Load

Load

12 to 
24 VDC

Brown

Black

Orange

Blue

Int

er

nal cir

cuits

Load

Load

12 to 
24 VDC

Brown

Black

Orange

Blue

Int

er

nal cir

cuits

Load

12 to 
24 VDC

Brown

Black

Orange

External 

input

Blue

Int

er

nal cir

cuits

Load

12 to 
24 VDC

Brown

Black

Orange

Blue

Output for 

channel 1

Output for 

channel 2

Output for 

channel 1

Output for 

channel 2

External 

input

Control output

Control 

output

12.50

(Communication Unit Connection Model)

31

19

The E2C-EDA0 is a communication unit connection model.

OMRON Corporation

Suitability for Use

EUROPE

OMRON EUROPE B.V. Sensor Business Unit

Carl-Benz Str.4, D-71154 Nufringen Germany

Phone:49-7032-811-0  Fax: 49-7032-811-199
NORTH AMERICA

OMRON ELECTRONICS  LLC

One Commerce Drive Schaumburg,IL 60173-5302 U.S.A.

Phone:1-847-843-7900  Fax : 1-847-843-7787
ASIA-PACIFIC

OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road #05-05-08(Lobby 2),

Alexandra Technopark, Singapore 119967 

Phone : 65-6835-3011  Fax :65-6835-2711

o

THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED.  
THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF 
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY 
COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.
Please refer to separate catalogs for OMRON's safety rated products.

OMRON shall not be responsible for conformity with any standards, codes, or 
regulations that apply to the combination of the products in the customer's 
application or use of the product. 
 
Take all necessary steps to determine the suitability of the product for the 
systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
 
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING 
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND 
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 