RUN
SET
Teaching
(Detection levels/Threshold display)
NO(normally-open)
NO
NC
NC(normally-close)
Single edge
Either the rising or falling
edge is detected.
Double edge
Both the rising and falling
edge are detected.
Detection level
Threshold value
Threshold value
The detection level
and threshold value
Timer disabled
----
OFFD
OFF-delay timer
ON-D
ON-delay timer
1SHT
One-shot timer
300μs
500μs
500μs
1ms
1ms
2ms
10ms
20ms
100ms
200ms
Single edge
This setting depends on the setting
for the differential edge selection.
Switch to SET mode.
Setting range: 1 to 5,000
Double edge
Standard mode
Response time: 1 ms
STND
HRES
High-resolution mode
Response time: 4 mss
DIFF
Not
SHS
Super-high-speed mode
Response time: 150μs
High-speed mode
Response time: 300μs
HS
Set separately for each channel for Twin-output Models.
2. Timer
5. Mode Key
Setting
6. Display Switch
7. Display
Orientation
9. Hysteresis Setup
10. External Input
Memory
4. External Input
3. Twin Outputs
8. Mutual Interference
Prevention
Number Set up
% detection level
O-PE
C-BT
PEAK
BOTM
Detection status
Peak level
Bottom level
The following functions can be set in SET mode. The default settings are shown in the transition boxes
between functions.
For Twin-output Models, all settings except for the operation mode, timer settings and hysteresis setting
are the same for both channels.
*: The values shown for thresholds, detection levels, percentages, etc., are examples only. Actual
displays may vary.
The item that is controlled by the input from an external
device can be selected.
Normal display
D123
321D
Reversed display
Write results to EEPROM.
ON
OFF
Do not write results to EEPROM.
NEAR
Positioning teaching
PPT
No-workpiece teaching
2PNT
Teaching with and without a workpiece
Effective Pulse Widths
FP
Fine positioning
0RST
Zero reset
0.1s to 2s
Executing: 0.1 to 2s
Clearing: 3s or longer
Effective ON pulse
width: 0.1s min.
Detection response
time 500
μ
s min.
Selection
Pulse width
SYNC
Synchronous detection
The function is detected only while
the input is ON.
Executes a fine positioning
FP
0RST
Executes a teaching with and
without a workpiece
2PNT
Executes a positioning teaching
PPT
Executes a zero reset
The function of the MODE key in RUN mode can be
selected.
Output for each channel.
2OUT
AREA
Output if level is between the two
thresholds.
SELF
HEAD
(Twin-output Models Only)
(External-input Models Only)
Mutual interference prevention does
not work.
OFF
(External-input Models Only)
Detection level
Channel
The detection level and
channel number
The output for channel 1 functions according to the
detection mode selection.
,
,
Detection level
Detection level
PEAK
Peak level
Display alternates
at a fixed interval.
Display alternates
at a fixed interval.
A
B
C
A
B
C
Switch to RUN mode.
Switch to RUN mode.
RUN
SET
6. Convenient Functions
Initializing Settings
RUN
SET
RUN
SET
Initialization has been
completed.
Key Lock
NO?
YES?
Switch to SET mode.
+
+
+
LOC
ON
LOC
OFF
INIT
INIT
GOOD
Hock on the Sensor Head connector end
DIN Track
DIN Track
1
2
1
1
2
1
2
(Unit: mm)
●
E2C-EDA11 and E2C-EDA6(NPN Models)
●
E2C-EDA41 and E2C-EDA8(PNP Models)
●
E2C-EDA21 and E2C-EDA7(NPN Models)
●
E2C-EDA51 and E2C-EDA9(PNP Models)
2.5
50.3
76
24.7
9.9
3.4
32
36.7
14
32
8.1
10
13.8
38.8
18.15
21.1
35.8
3.9×4=11.7
3.9×4=11.7
(Prewired Models)
The number of the amplifier which confirms mutual
interference prevention is set up.
Only the amplifier which wants to confirm mutual
interference prevention is made to connect, and it is
set as all amplifier.
After a setup should surely re-switch on a power supply.
The number of a setting: 2
[
2UT
]
to 5
[
5UT
]
5. Detailed Settings
AUTO
All key operations can be disabled to help prevent key operating errors.
Only the operation keys are disabled. The switches and selectors will still function.
This procedure can be used to return all the settings to the original default values.
●
Setting Method
●
Setting Method
●
Clearing Method
●
Mounting Units
Catch the hook on the Sensor Head connector end
of the Unit on the DIN Track and then press down
on the other end of the Unit until it locks into place.
Always attach the Sensor Head connector end first.
If the incorrect end is attached first, the mounting
strength will be reduced.
●
Removing Units
Press the Unit in the direction indicated by "1"
and then lift up on the Sensor Head connector
end of the Unit in the direction indicated by "2"
●
Mounting Amplifier Units in Group (Connector Type Models/Communication Unit
Connection Type Models)
Up to 16 connector type models can be connected. Up to 30 communication unit
connection type models can be connected to the communication unit
E3X-ECT, or 16 units to the E3X-CRT.
1. Mount the Amplifier Units one at a time onto the DIN Track.
2. Slide the Amplifier Units together and press the Amplifier
Units together until they click into place.
Secure the Units with an End Plate (PFP-M) if there is a
possibility of the Amplifier Units moving, e.g., due to vibration.
Reverse the above procedure to separate and remove the
Units. Do not attempt to remove Amplifier Units from the
DIN Track without separating them first.
7. Installing the Amplifier Unit
9. I/O Circuits
10. Dimensions
Lock button
1. Open the protective cover
2. A connector is turned so that a lock button may turn up,
and it inserts to the back.
To disconnect the Sensor Head, pull out the connector
while pressing on the lock button.
8. Connecting Sensor Heads
Display alternates
at a fixed interval.
Twin-output models can be set up for every channel.
Note: Refer to
4. Basic Settings for teaching methods.
Set separately for each channel.
0. Operation Mode
1. Detection Method
Differential
Edge Selection
Differential
Response Time
(Twin-output Models only)
Differential operation mode
Operation is according to the change
in the detection level.
For Twin-output Models, the output for
channel 2 is always an alarm output
for the absolute detection level.
Not
Timer Time
1-ms increments
1 to 20 ms
5-ms increments
20 to 200 ms
100-ms increments
200 ms to 1 s
1-s increments
1 to 5 s
The function of the output for channel 2 can be selected.
This setting is not value if DIFF (differential operation)
is set for the detection method. (The output for channel
2 is always an alarm output for differential operation.)
Self-diagnosis output
Output when the detection level
is not stable, i.e., when the detection
level is ±10% of the threshold value
for 300 ms or longer.
Disconnection output
A disconnection output is outputted,
when the Sensor Head is
disconnected, or it does not connect.
Automatic teaching
The maximum and minimum detection
levels are sampled while the input is ON and,
when the input turns OFF, the average of these
values is set as the threshold value.
Disabled if the detection function is set to
"DIFF" (differential operation).
The information displayed in RUN mode can be selected.
When going to SET mode, this setting will be ignored and
the detection level and threshold value will be displayed.
The detection level as
a percentage of the
threshold value and the
threshold value.
The peak detection
level and bottom
detection level of fixed
time(2s).
The peak detection level
under detection, and the
bottom detection level in
un-detecting.
A display is updated when
detection-un-detecting
changes.
Analog bar display. The
current detection status is
displayed as an analog
bar. The bar will lengthen
from the right as ON
status is reached.
The current detection
level and the peak
detection level.
Hysteresis is set up.
Hysteresis is adjusted to perform the case where
the position of a workpiece is unstable, and finer
detection.
Adjustment range: 10 to 2000
Whether external input execution results are written
to EEPROM can be selected.
Disable this function if the external input is turned
ON frequently. (The write life is approximately 100,000
writes.)
Hold down the MODE key and
press the UP key for at least 3
seconds. Press the UP key right
after pressing the MODE key.
Hold down the MODE key
and press the UP key for at
least 3 seconds. Press the
UP key right after pressing
the MODE key.
The sub-display will
flash twice and key
input will be disabled.
The sub-display will
flash twice and key
input will be enabled.
If a key is pressed while key operations are locked, "LOC" will flash
twice on the display to indicate that key operations have been disabled.
Press the UP or
DOWN key for at
least 3 seconds.
Press the MODE key at the
"NO?" or "YES?" display.
Settings not initialized.
Settings initialized.
Int
er
nal cir
cuits
Load
Load
12 to
24 VDC
Brown
Black
Orange
Blue
Int
er
nal cir
cuits
Load
Load
12 to
24 VDC
Brown
Black
Orange
Blue
Int
er
nal cir
cuits
Load
12 to
24 VDC
Brown
Black
Orange
External
input
Blue
Int
er
nal cir
cuits
Load
12 to
24 VDC
Brown
Black
Orange
Blue
Output for
channel 1
Output for
channel 2
Output for
channel 1
Output for
channel 2
External
input
Control output
Control
output
12.50
(Communication Unit Connection Model)
31
19
*
The E2C-EDA0 is a communication unit connection model.
OMRON Corporation
Suitability for Use
EUROPE
OMRON EUROPE B.V. Sensor Business Unit
Carl-Benz Str.4, D-71154 Nufringen Germany
Phone:49-7032-811-0 Fax: 49-7032-811-199
NORTH AMERICA
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,IL 60173-5302 U.S.A.
Phone:1-847-843-7900 Fax : 1-847-843-7787
ASIA-PACIFIC
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road #05-05-08(Lobby 2),
Alexandra Technopark, Singapore 119967
Phone : 65-6835-3011 Fax :65-6835-2711
o
THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED.
THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY
COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.
Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or
regulations that apply to the combination of the products in the customer's
application or use of the product.
Take all necessary steps to determine the suitability of the product for the
systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.