background image

D-37

E2A3

E2

A

3

Specifications

DC 3-wire Models

Note 1.

The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the 

standard sensing object length between sensing objects, and a set distance of half the sensing distance.

2.

For USA and Canada: use class 2 circuit only.

Size

M8

M12

M18

M30

Type

Shielded

Shielded

Shielded

Shielded

Item

E2A3-S08KS03-

@@

-B

@

E2A3-S08KS03-

@@

-C

@

E2A3-M12KS06-@@-B@
E2A3-M12KS06-@@-C@

E2A3-M18KS11-@@-B@
E2A3-M18KS11-@@-C@

E2A3-M30KS20-

@@

-B

@

E2A3-M30KS20-

@@

-C

@

Sensing distance

3 mm 

±

 10%

6 mm 

± 

10%

11 mm 

±

 10%

20 mm 

±

 10%

Setting 

distance

Ambient temp. of 

25 to 70°C

0 to 2.1 mm

0 to 4.2 mm

0 to 7.7 mm

0 to 14 mm

Ambient temp. of 

10 to 60°C

0 to 2.4 mm

0 to 4.8 mm

0 to 8.8 mm

0 to 16 mm

Differential travel

20% max. of sensing distance

Target 

Ferrous metal (The sensing distance decreases with non-ferrous metal.)

Standard sensing object

×

 9 

×

 1 mm

18 

×

 18 

×

 1 mm

33 

×

 33 

×

 1 mm

60 

×

 60 

×

 1 mm

Response frequency (See note 1.) 700 Hz

350 Hz

250 Hz

80 Hz

Power supply voltage 

(operating voltage range)

12 to 24 VDC. Ripple (p-p): 10% max.

(10 to 32 VDC)

Current consumption

10 mA max.

Output type

-B models: PNP open collector

-C models: NPN open collector

Control output

Load current 

200 mA max. (32 VDC max.)

Residual voltage

2 V max. (under load current of 200 mA with cable length of 2 m)

Indicator

Operation indicator (Yellow LED)

Operation mode

-B1/-C1 models:  NO

-B2/-C2 models:  NC

For details, refer to the timing charts.

Protection circuits

Power source circuit re-

verse polarity protection, 

Surge suppressor, Short-

circuit protection

Output reverse polarity protection, Power source circuit reverse polarity protec-

tion, Surge suppressor, Short-circuit protection

Ambient air temperature

Operating: 

25

°

C to 70

°

C, Storage: 

25

°

C to 70

°

C

Temperature influence 

±

20% max. of sensing distance at 23

°

C within temperature range of 

25

°

C to 70

°

C

10% to +20% of sensing distance at 23

°

C within temperature range of 

10

°

C to 60

°

C

Ambient humidity

Operating: 35% to 95%, Storage: 35% to 95%

Voltage influence

±

1% max. of sensing distance in rated voltage range 

±

15%

Insulation resistance

50 M

Ω

 min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case

Vibration resistance

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

500 m/s

2

, 10 times each 

in X, Y, and Z directions

1,000 m/s

2

, 10 times each in X, Y and Z directions

Standards and listings 

(See note 2.)

IP67 after IEC 60529

IP69K after DIN 40050

EMC after EN60947-5-2

Connection method

-WP models: Pre-wired Models (4-mm dia. PVC cable with length of 2 m)

-M1 models: M12 4-pin Connector Models

-M5 models: M8 3-pin Connector Models

Weight 

(packed state)

Pre-wired Models

Approx. 65 g

Approx. 85 g

Approx. 160 g

Approx. 280 g

Connector Models M12 Connector Models: 

Approx. 20 g

Approx. 35 g

Approx. 70 g

Approx. 200 g

Material

Case

Stainless steel

Brass-nickel plated

Sensing surface

PBT

Cable

PVC

Clamping nut

Stainless steel

Brass-nickel plated

Summary of Contents for E2A3 -

Page 1: ...B2 NPN E2A3 S08KS03 M1 C1 E2A3 S08KS03 M1 C2 M8 connector 3 pin 27 40 mm PNP E2A3 S08KS03 M5 B1 E2A3 S08KS03 M5 B2 NPN E2A3 S08KS03 M5 C1 E2A3 S08KS03 M5 C2 M12 Shielded 6 0mm Pre wired Brass 34 50 mm...

Page 2: ...2 m 1 Basic name E2A 2 Sensing technology Blank Standard double distance 3 Triple distance 3 Housing shape and material M Cylindrical metric threaded brass S Cylindrical metric threaded stainless ste...

Page 3: ...r details refer to the timing charts Protection circuits Power source circuit re verse polarity protection Surge suppressor Short circuit protection Output reverse polarity protection Power source cir...

Page 4: ...08KS03 X d t 1 mm Iron Brass Copper Stainless steel SUS303 Aluminum 7 6 5 4 3 2 1 0 0 5 10 15 20 25 30 Side length of sensing object d mm Sensing distance X mm E2A3 M12KS06 X d t 1 mm Iron Brass Coppe...

Page 5: ...2 Connector Pin Arrangement See note 2 M8 Connector 3 pin Pin Arrangement Note 2 Terminal 2 of the M12 connector is not used Proximity Sensor main circuits 100 0 Sensing object Rated sensing distance...

Page 6: ...of the M12 connector is not used Proximity Sensor main circuits 3 1 2 4 M12 Connector Pin Arrangement See note 2 3 1 4 M8 Connector 3 pin Pin Arrangement 100 0 Sensing object Rated sensing distance S...

Page 7: ...nductors Conduc tor cross section 0 3 mm2 Insulator diameter 1 3 mm Standard length 2 m 2 Operation indicator yellow M12 Connector Models E2A3 S08KS03 M1 Note Operation indicator yellow LED 4 90 E2A3...

Page 8: ...e Operation indicator yellow LED 4 90 39 8 26 8 4 5 13 Two clamping nuts M8 1 M8 1 Indicator See note Mounting Hole Cutout Dimensions F External diameter of Proximity Sensor Dimension F mm M18 M30 M8...

Page 9: ...etal When mounting the E2A3 within a metal panel ensure that the clearances given in the following tables are maintained Unit mm Unit mm Using the nuts provided with the E2A3 allows mounting in the wa...

Page 10: ...the Sensor Environment Water Resistivity The Proximity Sensors are tested intensively on water resistance but to ensure maximum performance and life expectancy avoid immer sion in water and provide pr...