background image

D4MC

D4MC

6

One-way Action Short Hinge Roller Lever 
D4MC-3030

Mounting Holes

Two 4.3 dia. mounting holes or
M4 screw holes

25.4 

±

 0.15

Note:

1.

Stainless steel lever

2.

Plastic roller

12.7 dia. 

×

 7.5

(see note 2)

t = 1 
(see note 1)

Terminal
protective
cover

Two, 4.3

±

0.1 dia.

mounting holes

Seal rubber (NBR)

Angle of roller
swing: 90

°

(21 x 21)

22 max.

15

14

Molded Terminal Models

 Molded Terminal Models

The molded terminal model is available with right-hand, left-hand and underside leads and is recommended for use where the Switch is ex-
posed to dust, oil, or moisture.

(2)

(3)

(1)

When placing your order for the Switch specify the required length
of V.C.T. cable in addition to the model number of the Switch

Example:
Standard type:

D4MC-5040

Location of lead outlet: Underside
Length of lead:

1 m (V.C.T. lead)

When placing your order for the above Switch specify the model
number as D4MC-5043 (V.C.T 1 m)

Suffix by Location of Lead Outlet

Location of lead outlet

Model

COM, NC, and NO

Right-hand

D4MC-

jjj

1

Left-hand

D4MC-

jjj

2

Underside

D4MC-

jjj

3

Leads Supplied

Leads

Nominal

cross-sectional

area

Finished outside diameter

Terminal

connections

Standard length

V.C.T. (Vinyl cabtire cable)

1.25 mm

2

Triple conductor: 10.5 mm dia.

Black: COM
White: NO
Red:

NC

1, 3, 5 m

 Terminal Protective Cover

ZC55 Terminal Cover (ZC55-0002H): 
The following three parts are supplied as a set.

Rubber packing

Terminal cover

Seal rubber

ZC Seal Rubber (SC-1404C)

Summary of Contents for D4MC

Page 1: ...r 5000 Panel mount plunger 5020 Panel mount roller plunger 5040 Panel mount crossroller plunger 1020 Short hinge lever 1000 Hinge lever 2000 Hinge roller lever 2020 Short hinge roller lever 3030 One w...

Page 2: ...ove figures are for steady state currents 2 Inductive loads have a power factor of 0 4 min AC and a time constant of 7 ms max DC 3 Lamp load has an inrush current of 10 times the steady state current...

Page 3: ...D IEC335 Rated operating current Ie 10 A Rated operating voltage Ue 250 VAC Vibration resistance Malfunction 10 to 55 Hz 1 5 mm double amplitude see note Shock resistance Destruction 1 000 m s2 min Ma...

Page 4: ...n Contact Form COM NO NC Dimensions Note 1 All units are in millimeters unless otherwise indicated 2 Unless otherwise specified a tolerance of 0 4 mm applies to all dimensions Panel Mount Plunger D4MC...

Page 5: ...3 0 1 dia mounting holes Seal rubber NBR 21 x 21 22 max 15 Hinge Lever D4MC 1000 Note Stainless steel lever t 1 see note Terminal protective cover Two 4 3 0 1 dia mounting holes Seal rubber NBR 21 x...

Page 6: ...cify the required length of V C T cable in addition to the model number of the Switch Example Standard type D4MC 5040 Location of lead outlet Underside Length of lead 1 m V C T lead When placing your...

Page 7: ...thus affect the sealing capability Rubber packing Rubber packing Mounting When mounting the Switch with screws on a side surface fasten the Switch with M4 screws and use washers spring washers etc to...