background image

G-251

D4B-

@

N

D4

B-

@

N

20

74

77

97

15

31.5

16

7.3

5.3

OP

PT

43

60

±

0.2

30

±

0.2

Conduit

40

+1
 0

8

16

20

77

97

PT

OP

8

5.3

7.3

15

31.5

43

74

60

±

0.2

30

±

0.2

Conduit

40

+1
 0

9.2 dia.

Cover

9.2 dia.

Cover

Top Plunger

D4B-

##

70N

Top Roller Plunger

D4B-

##

71N

Stainless steel 
plunger 

Two, 5.3-dia. 
mounting holes 

Two, M4 x 12 cover 
clamping screws 

Four, M3.5 x 24.5 
head clamping screws 

12.7 dia. x 4.8 
stainless steel roller

Two, 5.3-dia. 
mounting holes 

Two, M4 x 12 
cover clamping 
screws

Four, M3.5 x 24.5 
head clamping screws 

safety limit switch,  
mechanical form lock

safety limit switch,  
mechanical form lock

29.1

74

203.5

±

1.2

8

5.3

7.3

15.7

16

2.7

77

15

31.5

43

60

±

0.2

30

±

0.2

Conduit

40

+1
 0

Coil Spring

D4B-

##

81N

18.2 dia.

Rubber cap

Stainless steel coil spring

6.6 dia.

Cover

40 (see note 2)

(see note 1)

Coil Spring

Four, M3.5 x 7 
clamping screws 

Two, 5.3-dia. 
mounting holes 

Two, M4 x 12 cover 
clamping screws 

Note: 1.

 The coil spring may be operated 

from any directions except axial 
directions (

Ø

).

2.

 Be sure to adjust the dog to within 

40 mm from the top end of the coil 
spring.

203.5

±

1.2

60

±

0.2

30

±

0.2

61.5

29.1

7.3

5.3

43

31.5

15

74

77

2.7

15.7

16

8

Conduit

40

+1
 0

18.2 dia.

40 (see note)

6.6 dia.

Plastic rod

Seal cap

Cover

Plastic Rod

D4B-

##

87N

Four, M3.5 x 7 
head mounting 
screws

Two, 5.3-dia. 
mounting holes

Two, M4 x 12 cover 
mounting screws

The Switch can 
be actuated to all 
directions except 
to the axis center.

Note: 

Be sure to adjust the dog to within 40 mm 

from the top end of the plastic rod.

F502-EN2-04.book  Seite 251  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for D4B-1111N

Page 1: ...he applicable operating zone as well as push button switching to control left and right motion Conforms to EN T V standards cor responding to the CE marking 3 conduit switches are available Metric con...

Page 2: ...ote 1 D4B 1117N D4B 1517N D4B 1A17N D4B 2117N D4B 2517N D4B 2A17N D4B 4117N D4B 4517N D4B 4A17N Top plunger Plain form B D4B 1170N D4B 1570N D4B 1A70N D4B 2170N D4B 2570N D4B 2A70N D4B 4170N D4B 4570N...

Page 3: ...4NPT D4B 1100N D4B 2100N D4B 3100N D4B 5100N D4B 6100N D4B 7100N D4B 1500N D4B 2500N D4B 3500N D4B 5500N D4B 6500N D4B 7500N D4B 1A00N D4B 2A00N D4B 3A00N D4B 5A00N D4B 6A00N D4B 7A00N Actuator Type M...

Page 4: ...gI type or gG type 10 A fuse that conforms to IEC269 UL CSA UL508 CSA C22 2 No 14 A600 Agency Standard File No T V Rheinland EN60947 5 1 UL UL508 E76675 CSA C22 2 No 14 LR45746 BIA See note 2 GS ET 15...

Page 5: ...resistance 25 m max initial value Dielectric strength Uimp Between terminals of same polarity Uimp 2 5 kV Uimp 4 kV Between terminals of different polarity Uimp 4 kV Between current carrying metal pa...

Page 6: ...11 12 has an approved direct opening mechanism Terminal numbers 11 12 or 23 24 can be used as unlike poles 11 21 12 22 Zb 11 12 21 22 Stroke ON Both NC contacts 11 12 and 21 22 have an approved direc...

Page 7: ...lloy With roller lever models the direction of the switch head can be varied to any of the four directions by loosening the roller lever switch screws at the four corners of the head The roller lever...

Page 8: ...er Roller Lever D4B 11N M5 x 12 Allen head bolt Set position indicator plate Two 5 3 dia mounting holes Two M4 x 12 cover clamping screws Four M3 5 x 24 5 head clamping screws safety limit switch mech...

Page 9: ...31 5 43 60 0 2 30 0 2 Conduit 40 1 0 Coil Spring D4B 81N 18 2 dia Rubber cap Stainless steel coil spring 6 6 dia Cover 40 see note 2 see note 1 Coil Spring Four M3 5 x 7 clamping screws Two 5 3 dia mo...

Page 10: ...17N 145 max Two caps Cover Three Conduit 19 dia x 7 resin roller Two caps Cover Three Conduit 25 to 89R 40 to 42 40 to 42 Two 5 0 15 0 dia holes depth 6 Two 5 0 15 0 dia holes depth 6 Operating posi...

Page 11: ...D4B 81N 18 2 dia 40 to 42 Stainless steel coil spring Seal cap Two caps 6 6 dia Cover Three Conduit Plastic Rod D4B 87N Plastic rod 18 2 dia 40 to 42 Seal cap Two caps 6 6 dia Cover Three Conduit 40...

Page 12: ...Roller Lever compatible with previous D4B model Roller Lever 17 5 dia 30 nylon roller 7 3 0 1 dia 0 M5 hexagon socket head screw length 12 Roller Lever WL 1A106 50 dia 6 nylon roller M5 hexagon socke...

Page 13: ...WL 3A100 Spring Rod Lever WL 4A201 Resin Loop Lever D4A F00 Note Reverse the indicator plate when mounting Note Reverse the indicator plate when mounting Note Reverse the indicator plate when mountin...

Page 14: ...a tightening torque of 0 78 to 0 88 N m to conduit models Mounting Use four M5 screws with washers to mount the standard model Be sure to apply the proper torque to tighten each screw The D4B N can be...

Page 15: ...rque range The casing may be damaged if the connector is tight ened excessively If the 1 2 14NPT is used cover the cable and conduit end with seal ing tape in order to ensure IP67 The Pg13 5 connector...

Page 16: ...est of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounc...