F-14
General-purpose Limit Switch
D4A-
@N
Specifications
■
Approved Standards
■
Approved Standard Ratings
UL/CSA
A600
D4A-
@
1
@@
N (SPDT, Double-break, Without Indicator)
A300
D4A-
@
3
@@
N (SPDT, Double-break, With Neon Lamp)
B600
D4A-
@
5
@@
N (DPDT, Double-break, Simultaneous Operation)
D4A-
@
7
@@
N (DPDT, Double-break, Sequential Operation)
D4A-
@
9
@@
N (DPDT, Double-break, Center Neutral Operation)
Agency
Standard
File No.
UL
UL508
E76675
CSA
CSA C22.2 No. 14
LR45746
Rated voltage
Carry current
Current
Volt-amperes
Make
Break
Make
Break
120 VAC
240 VAC
480 VAC
600 VAC
10 A
60 A
30 A
15 A
12 A
6 A
3 A
1.5 A
1.2 A
7,200 VA
720 VA
Rated voltage
Carry current
Current
Volt-amperes
Make
Break
Make
Break
120 VAC
240 VAC
10 A
60 A
30 A
6 A
3 A
7,200 VA
720 VA
Rated voltage
Carry current
Current
Volt-amperes
Make
Break
Make
Break
120 VAC
240 VAC
480 VAC
600 VAC
5 A
30 A
15 A
7.5 A
6.0 A
3 A
1.5 A
0.75 A
0.6 A
3,600 VA
360 VA