135
Pulse Outputs
Section 7-6
7-6-4
Precaution in Using Pulse Outputs
Pulses are output from the CS1W-HCP22-V1 according to the clock fre-
quency specified in the Unit Setup Area (bits 08 to 15 of DM 6613 and DM
6614: 25 MHz, 6.25 MHz, 1.5625 MHz, or 390.625 kHz). The clock signal is
divided by an integer dividing ratio to create and output the output pulse fre-
quency. This means that the actual frequency may not be the same as the tar-
get frequency. Refer to the following information to calculate the actual
frequency.
The following information is used to calculate the output frequency.
Target frequency:
Set by user.
Dividing ratio:
An integer set in the dividing circuit used to generate the output pulses at the
target frequency.
Actual frequency:
The actual frequency that is output as generated by the dividing circuit.
Formula:
Actual frequency = Clock frequency
¸
INT (clock frequency/target frequency)
Note
INT (clock frequency/target frequency) is the dividing ratio.
The difference between the target frequency and the actual frequency
increases at higher frequencies. The following tables shows examples for a
clock frequency of 25 MHz.
Target frequency (Hz)
Actual output frequency
198,413 to 200,000
200,000
196,851 to 198,412
198,412
195,313 to 196,850
196,850
|
|
151,516 to 152,439
152,439
150,603 to 151,515
151,515
149,701 to 150,602
150,602
|
|
100,402 to 100,806
100,806
100,001 to 100,401
100,401
99,602 to 100,000
100,000
|
|
50,101 to 50,200
50,200
50,001 to 50,100
50,100
49,901 to 50,000
50,000
|
|
402
402
401
401
400
400
Dividing circuit
Actual output frequency
Integer dividing ratio set
according to the target
frequency set by user.
Clock-generated pulses
(one of four settings
possible)
Summary of Contents for CS1W-HCA12-V1
Page 2: ......
Page 6: ...vi...
Page 20: ...xx Conformance to EC Directives 7...
Page 38: ...18 Models and System Configurations Section 1 2...
Page 78: ...58 Fail safe Circuits Section 3 5...
Page 138: ...118 AR Area Section 6 4...
Page 204: ...184 Improved Instructions Section 7 14...
Page 222: ...202 Cycle Time Section 8 3...
Page 240: ...220 Troubleshooting Flowcharts Section 9 5...
Page 244: ...224 Precautions when Using the CX Programmer Appendix A...
Page 252: ......
Page 253: ......