Omron CJ1M-CPU12 Brochure Download Page 14

18

Pulse with Variable Duty Factor (PWM) Output Function

Hardware Specifications

Input Specifications

Circuit Configuration

Item

Specification

Duty ratio

0% to 100%, set in 1% units

Frequency

0.1 to 999.9 Hz, set in 0.1-Hz units

Instruction for PWM

PWM (PULSE WITH VARIABLE DUTY FACTOR): Used to output pulses with the specified duty factor.

Item

Specification

Number of input points

10 points

Input type

24-VDC input or line driver input (switched with wiring)

24-VDC input

Line driver input

Input points

IN0 to IN5

IN6 to IN9

IN0 to IN5

IN6 to IN9

Input voltage

20.4 to 26.4 VDC

Conforms to RS-422 line driver (equivalent to 
AM26LS31).

The power supply voltage on the connected 
side must be 5 V

±

5%.

Input impedance

3.6 k

4.0 k

Input current (typ.)

6.2 mA

4.1 mA

13 mA

10 mA

ON voltage (min.)

17.4 VDC min./3 mA min.

-

ON voltage (max.)

5.0 VDC/1 mA max.

-

Response speed (for 
general-purpose input)

ON response time

8 ms max. (Select 0, 0.05, 1, 2, 4, 8, 16, or 32 ms in PC Setup.)

OFF response time 8 ms max. (Select 0, 0.05, 1, 2, 4, 8, 16, or 32 ms in PC Setup.)

Input

IN0 to IN5

IN6 to IN9

Circuit 
configuration

24 V

LD+

0 V/LD

100 

1000 pF

100 

750 

3.6 k

Inter

nal circuit

24 V

LD+

0 V/LD

100 

1000 pF

100 

1.5 K

4.0 k

Inter

nal circuit

Summary of Contents for CJ1M-CPU12

Page 1: ...1 02 Printed in Japan 1002 3M Note Do not use this document to operate the Unit OMRON Corporation FA Systems Division H Q 66 Matsumoto Mishima city Shizuoka 411 8511 Japan Tel 81 55 977 9181 Fax 81 55...

Page 2: ......

Page 3: ......

Page 4: ...A computer is not required at the production site enabling downsizing and cost reductions...

Page 5: ......

Page 6: ...W KS001 E See below CX Programmer Ver 3 0 WS02 CXPC1 EV3 XW2Z 200S CV for IBM PC AT or compatible XW2Z 500S CV for IBM PC AT or compatible 5 m CX Simulator Ver 1 3 WS02 SIMC1 E Serial Communications U...

Page 7: ...Unit CPU Rack 10 Units Expansion Rack 10 Units 20 Ksteps CJ1M CPU22 320 None 10 Units 10 Ksteps 10 inputs and 6 outputs Inputs 4 interrupt inputs pulse catch 2 high speed counter inputs Phase differe...

Page 8: ...Bus S Master Units I O Units with 31 mm width Basic I O Units other than the above Special I O Units CPU Bus Units Model Current consumption at 5 V Current consumption at 24 V CJ1M CPU12 CPU13 0 58 A...

Page 9: ...0000 to CIO 0999 I O bits are allocated to Basic I O Units These bits can be used as work bits when not used for the applications de scribed on the left Built in I O Area 10 input bits CIO 296000 to C...

Page 10: ...the PLC is turned OFF or the operating mode is changed Index Registers IR0 to IR15 Store PLC memory addresses for indirect addressing Task Flag Area 32 TK0000 to TK0031 Task Flags are read only flags...

Page 11: ...ks Clock Provided on all models Accuracy 1 5 min mo at 25 C Note 1 The accuracy varies with the temperature 2 Used to store time when power is turned ON and when errors occur Power OFF detection time...

Page 12: ...purpose output 4 General purpose output 5 Pulse output CW CCW Pulse output 0 CW Pulse output 0 CCW Pulse output 1 CW Pulse output 1 CCW Pulse direc tion Pulse output 0 pulse Pulse output 1 pulse Pulse...

Page 13: ...d counter 0 A531 bit 01 high speed counter 1 Item Specification Output frequency 1 Hz to 100 kHz 1 to 100 Hz 1 Hz units 100 Hz to 4 kHz 10 Hz units 4 to 100 kHz 100 Hz units Frequency acceleration dec...

Page 14: ...nts IN0 to IN5 IN6 to IN9 IN0 to IN5 IN6 to IN9 Input voltage 20 4 to 26 4 VDC Conforms to RS 422 line driver equivalent to AM26LS31 The power supply voltage on the connected side must be 5 V 5 Input...

Page 15: ...r point for 10 ms max Leakage current 0 1 mA max Residual voltage 0 6 V max ON response time 0 1 ms max OFF response time 0 1 ms max Fuse None External power supply 10 2 to 26 4 VDC 50 mA min Circuit...

Reviews: