Summary of Contents for BP742N

Page 1: ...INSTRUCTION MANUAL ESPA OL ENGLISH 5 series Blood Pressure Monitor Model BP742N...

Page 2: ...ing the Date and Time 14 Using the Device 15 Applying the Arm Cuff 15 How to Sit Correctly 17 Taking a Measurement 17 Using the Memory Function 20 Care and Maintenance Error Messages and Troubleshooti...

Page 3: ...c monitor does not need a stethoscope so the monitor is simple to use Intended Use This device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient populat...

Page 4: ...on arterial sclerosis poor perfusion diabetes age pregnancy pre eclampsia renal diseases Note that PATIENT motion trembling shivering may affect the measurement reading Do not use the device on the in...

Page 5: ...Do not use this device on infants or persons who cannot express their intentions Do not use the device for any purpose other than measuring blood pressure Use only the approved arm cuff for this devic...

Page 6: ...take care not to do the following Do not damage Do not break it Do not tamper with it Do not forcibly bend or pull Do not twist Do not bundle during use Do not pinch Do not place under heavy objects...

Page 7: ...tion with the monitor not the tube itself Do not drop the monitor or subject device to strong shocks or vibrations Do not inflate the arm cuff when it is not wrapped around your arm Do not use the dev...

Page 8: ...tor Arm cuff A Display B Up Down buttons C USER ID selection switch D Date Time setting button E START STOP button F Memory button G Battery compartment H Air jack I AC adapter jack for optional AC ad...

Page 9: ...sure P Low battery symbol Q Heartbeat symbol Flashes during measurement R Memory symbol S Average value symbol T Date Time display U Movement error symbol V Irregular heartbeat symbol W Blood pressure...

Page 10: ...etected while the monitor is measuring the systolic and diastolic blood pressure If the irregular heartbeat symbol displays with your measurement results we recommend you consult your physician Follow...

Page 11: ...elines for the management of arterial hypertension Definitions of hypertension by office and home blood pressure levels Office Home Systolic Blood Pressure 140 mmHg 135 mmHg Diastolic Blood Pressure 9...

Page 12: ...ts should be taken in a quiet place 4 Remove tight fitting clothing from your arm 5 Sit on a chair with your feet flat on the floor Rest your arm on a table so that the arm cuff is at the same level a...

Page 13: ...play turn the monitor off then replace all batteries at the same time Long life alkaline batteries are recommended The measurement values continue to be stored in memory even after the batteries are r...

Page 14: ...d then the month flashes Repeat the same steps to change the month day hour and minute Minute Change Confirm Change Confirm Change Confirm Change Confirm Change Confirm Year Month Day Hour Forward Bac...

Page 15: ...Do not place the arm cuff over thick clothes 1 Insert the air plug into the air jack securely 2 Wrap the arm cuff firmly in place around your left upper arm 1 2 inch 1 2 cm The bottom edge of the arm...

Page 16: ...Be careful not to rest your arm on the air tube The blood pressure can differ between the right arm and the left arm and the measured blood pressure values can be different OMRON recommends to always...

Page 17: ...on the floor Sit upright with your back straight Sit with your back and arm being supported The arm cuff should be placed on your arm at the same level as your heart Taking a Measurement Notes To sto...

Page 18: ...lic pressure is more than 210 mmHg After the arm cuff starts to inflate press and hold the START STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure Notes...

Page 19: ...ry The guest mode can be used to take a single measurement for another user No measurement values are stored in the memory when the guest mode is selected 1 Press and hold the START STOP button for mo...

Page 20: ...es Notes If there are only 2 measurement values in the memory for that period the average will be based on these 2 values If there is 1 measurement value in the memory for that period this is displaye...

Page 21: ...t values To View the Average Value 1 Select your User ID 1 or 2 2 Press and hold the button for more than 3 seconds Notes If the previous measurement was taken without setting the date and time the av...

Page 22: ...deleted by USER ID 1 Select your User ID 1 or 2 2 Press the button while the memory symbol appears 3 While holding the button down press the START STOP button for more than 3 seconds Note You cannot p...

Page 23: ...ing a Measurement The batteries are low You should replace the batteries with new ones ahead of time Refer to Battery Installation The batteries are exhausted You should replace the batteries with new...

Page 24: ...ment The arm cuff was inflated exceeding the maximum allowable pressure and then deflated automatically when inflating the arm cuff manually Do not touch the arm cuff and or bend the air tube while ta...

Page 25: ...installation for proper placement of the battery polarities Refer to Battery Installation Measurement values appear too high or too low Blood pressure varies constantly Many factors including stress t...

Page 26: ...wash the device and any components or immerse them in water Do not use gasoline thinners or similar solvents to clean the device Use a soft and dry cloth or a soft and moistened cloth and neutral soap...

Page 27: ...ly Do not store the device in the following situations If the device is wet Locations exposed to extreme temperatures humidity direct sunlight dust or corrosive vapors such as bleach Locations exposed...

Page 28: ...t the AC adapter plug into the AC adapter jack on the rear side of the monitor 2 Plug the AC adapter into an electrical outlet To disconnect the AC adapter unplug the AC adapter from the electrical ou...

Page 29: ...temperature humidity 50 F to 104 F 10 C to 40 C 15 to 90 RH Storage temperature humidity air pressure 4 F to 140 F 20 C to 60 C 10 to 95 RH 700 to 1060 hPa Weight Monitor Approximately 10 5 8 oz 300 g...

Page 30: ...pecifications are subject to change without notice In the clinical validation study the 5th phase was used on 85 subjects for determination of diastolic blood pressure This device has not been validat...

Page 31: ...talled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation I...

Page 32: ...dling fee Enclose the original printed receipt Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit Beca...

Page 33: ...althcare conform to this IEC60601 1 2 2007 standard for both immunity and emissions Nevertheless special precautions need to be observed The use of accessories and cables other than those specified by...

Page 34: ...ions CISPR 11 Group 1 The OMRON BP742N including AC adapter uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby...

Page 35: ...V line s to line s 2 kV line s to earth 1 kV line s to line s 2 kV line s to earth Mains power quality should be that of a typical commercial and or hospital environment Voltage dips short interruptio...

Page 36: ...engths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipme...

Page 37: ...ions equipment Output Power of Transmitter in Watt Separation distance according to frequency of transmitter in meter 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5GHz d 2 3 P 0 01...

Page 38: ...LTHCARE Co Ltd 53 Kunotsubo Terado cho Muko Kyoto 617 0002 JAPAN Distributed by OMRON HEALTHCARE INC 1925 West Field Court Lake Forest IL 60045 U S A www omronhealthcare com 2013 OMRON HEALTHCARE INC...

Reviews: