background image

ESP

AÑOL

ENGLISH

INSTRUCTION MANUAL

Wrist Blood

Pressure Monitor

Model BP653

Summary of Contents for BP653

Page 1: ...ESPA OL ENGLISH INSTRUCTION MANUAL Wrist Blood Pressure Monitor Model BP653...

Page 2: ...r high normal 10 Battery installation 12 Setting the date and time 14 Applying the wrist cuff 15 Applying the cuff on the left wrist 15 Applying the cuff on the right wrist 16 Taking a measurement 17...

Page 3: ...ts the movements into a digital reading An oscillometric monitor does not need a stethoscope so the monitor is simple to use Clinical research has proven a direct relationship between blood pressure i...

Page 4: ...ce for any of the following conditions common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation arterial sclerosis poor perfusion diabetes age pregnancy pre eclampsia re...

Page 5: ...Do not take measurements more than necessary It may cause bruising due to blood flow interference Read all of the information in the instruction manual and any other literature in the box before oper...

Page 6: ...on Changes or modification not approved by the manufacturer will void the user warranty Do not disassemble or attempt to repair the unit or components This may cause an inaccurate reading as well Do n...

Page 7: ...3 The cuff can be applied to your left or right wrist 4 Measurements should be taken in a quiet place 5 Position the unit at heart level throughout the measurement 6 Remain still and do not talk durin...

Page 8: ...ton Transfer button Date Time setting button USER ID1 USER ID2 USER ID selection switch Wrist cuff INTRODUCTION Thank you for purchasing the OMRON BP653 Wrist Blood Pressure Monitor Fill in for future...

Page 9: ...ressure Battery symbol low depleted Pulse display Memory number Deflation symbol Transfer symbol Memory full symbol OK symbol Positioning indicator Memory symbol Blood pressure level indicator High No...

Page 10: ...ular heartbeat symbol displays with your readings we recommend you consult your physician Follow the directions of your physician MOVEMENT ERROR SYMBOL The Movement Error Symbol is displayed if you mo...

Page 11: ...ESC Guidelines for the management of arterial hypertension Definitions of hypertension by office and home blood pressure levels Systolic Blood Pressure Office Home 135 mmHg Diastolic Blood Pressure 85...

Page 12: ...ely Keep the batteries out of the reach of young children 1 Push down the hook of the battery cover and pull downward 2 Install 2 AAA size batteries so the positive and negative polarities match the p...

Page 13: ...time Turn the unit off before replacing the batteries If the batteries are removed while the unit is still on the date and time will be reset to that of the previous use The readings are not deleted...

Page 14: ...he START STOP button to store the setting NOTES If the batteries have been removed the date and time setting will need to be reset The date and time can be automatically set when you transfer your rea...

Page 15: ...on your arm This may constrict the flow of blood in your arm 2 Put your arm through the cuff loop Your palm should face upward 3 Position the cuff leaving a clearance of approximately 1 2 inch 1 cm to...

Page 16: ...er the protruding part of the wrist bone on the outside of the wrist If the wrist cuff comes off re assemble as shown in the figure APPLYING THE CUFF ON THE RIGHT WRIST When taking a measurement using...

Page 17: ...unable to make any seat or table adjustments please turn off the position indicator and position your wrist at heart level by yourself The cuff must be approximately the same height as your heart If...

Page 18: ...be blue If the positioning indicator changes to orange the device may not be at the correct height relative to your heart Due to difference in individual size and physique this feature may not helpful...

Page 19: ...stop inflating start deflating and will turn off 4 Press the START STOP button to turn the monitor off NOTES The monitor will automatically turn off after 2 minutes Wait 2 3 minutes between measuremen...

Page 20: ...iewing the readings taken without setting the date and time is displayed instead of the date and time If there are no readings stored in the memory the screen to the right is displayed 3 Press the but...

Page 21: ...u to begin to transfer your readings 3 Press and hold the button for more than 2 seconds The transfer symbol will appear on the display 4 Open the App on your smartphone and follow the device pairing...

Page 22: ...memory TO DELETE ALL THE READINGS STORED IN MEMORY The readings stored in the memory are deleted by USER ID 1 Select your USER ID 1 or 2 2 Press the button the memory symbol appears 3 While holding th...

Page 23: ...device will not delete the information in the mobile App The monitor will automatically turn off after 2 minutes If you re pair your smartphone to your blood pressure monitor all prior reading histor...

Page 24: ...quid gets in the cuff dry the inside well CAUTION Do not wash the device and any components or immerse them in water Do not subject the monitor to extreme hot or cold temperatures humidity or direct s...

Page 25: ...not disassemble or attempt to repair the unit or components CAUTION Do not store the device in the following situations If the device is wet Locations exposed to extreme temperatures humidity direct...

Page 26: ...ment Repeat the steps in section Taking a Measurement If this error continues to appear contact your physician Do not hold the wrist cuff Remain still and do not talk during measurement Refer to Takin...

Page 27: ...ION Recommend to replace the batteries with new ones ahead of time Refer to Battery Installation Replace the two batteries Refer to Battery Installation Contact Customer Service Device error Batteries...

Page 28: ...o far away from the monitor After checking that there are no sources of interference nearby move the device to a distance within 16 ft 5 m of the monitor The Bluetooth function on the destination devi...

Page 29: ...the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between...

Page 30: ...Product before using this Product or do not use this Product around the other wireless devices The Bluetooth Smart word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use...

Page 31: ...loss in transit we recommend insuring the product with return receipt requested THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN CONNECTION WITH THIS PRODUCT AND OMRON HEREBY DISCLAIMS ANY OTH...

Page 32: ...ies 1 5V Approximately 300 uses with 2 new alkaline batteries 50 F to 104 F 10 C to 40 C 15 RH to 90 RH 4 F to 140 F 20 C to 60 C 10 RH to 95 RH 700 hPa to 1060 hPa Approximately 3 1 2 oz 100 g not in...

Page 33: ...ured by OMRON Healthcare conform to this IEC60601 1 2 2007 standard for both immunity and emissions Nevertheless special precautions need to be observed The use of accessories and cables other than th...

Page 34: ...s used in such environment Electromagnetic environment guidance Group 1 Class B RF emissions CISPR 11 RF emissions CISPR 11 The OMRON BPM uses RF energy only for its internal function Therefore its RF...

Page 35: ...is OMRON BPM should assure that it is used in such environment Electrostatic discharge ESD IEC 61000 4 2 Electrical fast transient burst IEC 61000 4 4 Surge IEC 61000 4 5 Floor should be wood concrete...

Page 36: ...Power frequency 50 60 Hz magnetic field IEC 61000 4 8 Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment Not Appli...

Page 37: ...OMRON BPM should assure that it is used in such environment Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 Portable and mobile RF communications equipment should be used no closer to any part of...

Page 38: ...agnetic site survey should be considered If the measured field strength in the location in which the OMRON BPM is used exceeds the applicable RF compliance level above the OMRON BPM should be observed...

Page 39: ...between portable and mobile RF communications equipment transmitters and the OMRON BPM as recommended below according to the maximum output power of the communications equipment 150 kHz to 80 MHz Not...

Page 40: ...r OMRON HEALTHCARE Co Ltd 53 Kunotsubo Terado cho Muko Kyoto 617 0002 JAPAN Distributed by OMRON HEALTHCARE INC 1925 West Field Court Lake Forest IL 60045 U S A www omronhealthcare com 2014 OMRON HEAL...