background image

5

SAFETY INFORMATION

INTENDED USE

The device is a digital monitor intended for use in measuring blood pressure and 

pulse rate in adult patient population with wrist circumference ranging from 5 1/4 

inches to 8 1/2 inches (13.5 cm to 21.5 cm). The device detects the appearance of 

irregular heartbeats during measurement and gives a warning signal with readings.

OPERATING THE DEVICE

Consult your physician for specific information about your blood pressure. 

Self-diagnosis and treatment using readings may be dangerous. Follow the 

instructions of your physician or licensed healthcare provider.
DO NOT adjust medication based on readings from this blood pressure monitor. 

Take medication as prescribed by your physician. Only a physician is qualified to 

diagnose and treat High Blood Pressure.
The monitor is not intended to be a diagnostic device.
Consult your physician before using the device for any of the following conditions: 

common arrhythmias such as atrial or ventricular premature beats or atrial 

fibrillation, arterial sclerosis, poor perfusion, diabetes, age, pregnancy, 

pre-eclampsia, renal diseases.
Note that PATIENT motion, trembling, shivering may affect the reading.
If battery fluid should get in your eyes, immediately rinse with plenty of clean 

water. Consult a physician immediately.
Keep the batteries out of reach of young children.
Do not use the device on the injured wrist or the wrist under medical treatment.
Consult your physician before using the device on the arm with an arterio-venous 

(A-V) shunt.
Do not use the device with other medical electrical (ME) equipment simultaneously.

Do not use the device in the area the HF surgical equipment, MRI, or CT scanner 

exists, or in the oxygen rich environment.
Consult your physician before using the device for any of the following conditions:
• If you have had a mastectomy.
• Do not take measurements more than necessary. It may cause bruising due to 

blood flow interference.

• People with severe blood flow problems or blood disorders as cuff inflation can 

cause bruising.

If you have a condition that may compromise circulation, you may get an inaccurate 

reading with this device. Consult your physician before using this device.
Read all of the information in the instruction manual and any other literature in the 

box before operating the unit.
Do not use this device on infants or persons who cannot express their intentions.
Operate the device only as intended. Do not use the device for any other purpose.
Dispose of the device, components and optional accessories according to applicable 

local regulations. Unlawful disposal may cause environmental pollution.
Do not use a mobile phone near the device. It may result in an operational failure.
Use only Omron authorized parts and accessories. Parts and accessories not 

approved for use with the device may damage the unit.
Use only 1.5V Alkaline batteries with this device. Do not use other types of 

batteries. This may damage the device.
Do not use in a location with moisture, or a location where water may splash on the 

unit. This may damage the device.

CARE AND MAINTENANCE

Do not subject the monitor to strong shocks, such as dropping the unit on the 

floor.
Do not submerge the device or any of the components in water.
Store the device and the components in a clean, safe location.
Changes or modification not approved by the manufacturer will void the user 

warranty. Do not disassemble or attempt to repair the unit or components.
Do not use the device outside the specified environment. It may cause an 

inaccurate reading.

Downloaded from 

www.Manualslib.com

 

manuals search engine

 

Summary of Contents for BP652

Page 1: ...ESPA OL ENGLISH ESPA OL ENGLISH INSTRUCTION MANUAL Model BP652 Wrist Blood Pressure Monitor Downloaded from www Manualslib com manuals search engine...

Page 2: ...Battery replacement 12 Setting the date and time 13 Applying the arm cuff 15 Applying the cuff on the left wrist 15 Applying the cuff on the right wrist 16 Taking a measurement 17 Using the memory fun...

Page 3: ...ecause the arteries in the wrist and the arm are close to each other Frequently measuring the blood pressure in your wrist will provide your physician with an accurate indication of changes in your bl...

Page 4: ...any of the following conditions common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation arterial sclerosis poor perfusion diabetes age pregnancy pre eclampsia renal dis...

Page 5: ...vice components and optional accessories according to applicable local regulations Unlawful disposal may cause environmental pollution Do not use a mobile phone near the device It may result in an ope...

Page 6: ...to your left or right wrist 4 Measurements should be taken in a quiet place 5 Position the unit at heart level throughout the measurement 6 Remain still and do not talk during the measurement 7 Keep a...

Page 7: ...n the wrist and blood pressure in the arm Changes in wrist blood pressure reflect changes in arm blood pressure because the arteries in the wrist and the arm are close to each other Frequently measuri...

Page 8: ...essure level indicator bar Systolic blood pressure Date Time display Positioning symbol Diastolic blood pressure Low battery symbol Pulse display Memory number Deflation symbol Irregular heartbeat sym...

Page 9: ...ar Heartbeat Symbol will appear on the display with the readings An irregular heartbeat rhythm is defined as a rhythm that varies by less than 25 from the average rhythm or 25 more than the average rh...

Page 10: ...essure Self diagnosis and treatment using readings may be dangerous Follow the instructions of your physician or licensed healthcare provider 2013 ESH ESC Guidelines for the management of arterial hyp...

Page 11: ...l downward 2 Install 2 AAA size batteries so the positive and negative polarities match the polarities of the battery compartment as indicated 3 Replace the battery cover NOTE Make sure that the batte...

Page 12: ...hen the batteries are replaced you may need to reset the date and time Refer to Setting the Date and Time The batteries included with the device may have a shorter life CAUTION Dispose of the device c...

Page 13: ...button to advance by one year Press the Date Time Setting button to set the current year The month flashes on the display NOTES The year can be set between 2015 and 2040 When the display reaches 2040...

Page 14: ...set using AM or PM Press the Date Time Setting button to advance by one hour Press the Date Time Setting button to set the current hour The minute flashes on the display 6 SETTING THE MINUTE Press th...

Page 15: ...evice on infants or persons who cannot express their intentions APPLYING THE CUFF ON THE LEFT WRIST 1 Roll up sleeve Make sure your sleeve is not rolled up too tightly on your arm This may constrict t...

Page 16: ...not cover the protruding part of the wrist bone on the outside of the wrist If the wrist cuff comes off re assemble as shown in the figure APPLYING THE CUFF ON THE RIGHT WRIST When taking a measureme...

Page 17: ...this parameter please correct your seat or table height If you are unable to make any seat or table adjustments please turn off the position sensor and position your wrist at heart level by yourself...

Page 18: ...t be at the correct height relative to your heart Due to difference in individual size and physique this feature may not helpful in all cases and you may wish to turn off this feature If you feel the...

Page 19: ...low Forward bent posture NOTE Even if the device is not positioned properly and the Positioning indicator is orange after 5 seconds the monitor will start the measurement and the wrist cuff will star...

Page 20: ...ing start deflating and will turn off 3 After the monitor has detected your blood pressure and pulse rate the cuff automatically deflates Your blood pressure and pulse rate are displayed 4 Press the S...

Page 21: ...readings may be dangerous Follow the instructions of your physician or licensed healthcare provider WARNING DO NOT adjust medication based on readings from this blood pressure monitor Take medication...

Page 22: ...adings taken within 10 minutes NOTE If two readings are stored in the memory for the 10 minute period the average is based on the two readings If only one reading is stored this is displayed as the av...

Page 23: ...ry button to display the readings faster 3 Press the START STOP button to turn the monitor off TO DELETE ALL READINGS STORED IN THE MEMORY You cannot partially delete readings stored in the memory All...

Page 24: ...treme hot or cold temperatures humidity or direct sunlight CAUTION Store the device and the components in a clean safe location CAUTION Do not subject the monitor to strong shocks such as dropping the...

Page 25: ...king a Measurement Remain still until the measurement is complete Refer to Taking a Measurement Contact Customer Service Apply the wrist cuff correctly Refer to Applying the Wrist Cuff Remain still an...

Page 26: ...attery installation for proper placement of the battery polarities Review the section Battery Installation Blood pressure varies constantly Many factors including stress time of day how you wrap the c...

Page 27: ...ructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interfe...

Page 28: ...mend insuring the product with return receipt requested THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN CONNECTION WITH THIS PRODUCT AND OMRON HEREBY DISCLAIMS ANY OTHER WARRANTIES EXPRESS OR...

Page 29: ...ing Pulse 5 of reading Automatic by electric pump Automatic rapid deflation Oscillometric method 2 AAA alkaline batteries 1 5V Approximately 300 uses with 2 new alkaline batteries 50 F to 104 F 10 C t...

Page 30: ...to change without notice In the clinical validation study the 5th phase was used on 85 subjects for determination of diastolic blood pressure This device has not been validated for use in pregnancy D...

Page 31: ...l as maximum levels of electromagnetic emissions for medical devices Medical devices manufactured by OMRON Healthcare conform to this IEC60601 1 2 2007 standard for both immunity and emissions Neverth...

Page 32: ...RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment The OMRON BPM is suitable for use in all es...

Page 33: ...e that it is used in such environment Electrostatic discharge ESD IEC 61000 4 2 Electrical fast transient burst IEC 61000 4 4 Surge IEC 61000 4 5 Floor should be wood concrete or ceramic tile If floor...

Page 34: ...netic field IEC 61000 4 8 Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment Not Applicable 5 UT 95 dip in UT for...

Page 35: ...tomer or the user of this OMRON BPM should assure that it is used in such environment Conducted RF IEC 61000 4 6 Portable and mobile RF communications equipment should be used no closer to any part of...

Page 36: ...facturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compli ance level...

Page 37: ...cast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field st...

Page 38: ...t transmitters and the OMRON BPM as recommended below according to the maximum output power of the communications equipment 150 kHz to 80 MHz Not Applicable For transmitters rated at a maximum output...

Page 39: ...THCARE Co Ltd Distributed by OMRON HEALTHCARE INC 1925 West Field Court Lake Forest IL 60045 U S A www omronhealthcare com 2014 OMRON HEALTHCARE INC Made in China 9701555 9A Downloaded from www Manual...

Reviews: