4. Using Your Monitor with a Smart Device

5. Press the [START/STOP] button to turn your 

monitor off.

Note

• If the “Err” symbol appears, follow the instructions in the 

“OMRON connect US/CAN” app.

• Your monitor automatically turns off after 2 minutes.

• Be aware that OMRON will not be responsible for the loss of 

data and/or information in the app.

• “OMRON connect US/CAN” is the only app that we 

recommend to use with your monitor to transfer data 

correctly.

4.2

Taking a Measurement

Refer to sub-section 3.1 to start a measurement. Open the app on 

your smart device and follow the instructions.

Note

•Make sure that your monitor is within 16 ft. (5 m) of your smart 

device.

Transferring Data Automatically/Manually

•The readings will be transferred to your smart device within 1 hour 

after taking a measurement.

•To transfer the readings manually, press the 

button.

Summary of Contents for BP5350

Page 1: ...3787131 6A Gold Upper Arm Blood Pressure Monitor Model BP5350 Instruction Manual EN...

Page 2: ...aking a Measurement 22 4 Using Your Monitor with a Smart Device 25 4 1 Pairing Your Monitor with a Smart Device 25 4 2 Taking a Measurement 26 4 3 Disabling Enabling Bluetooth 27 5 Using Memory Functi...

Page 3: ...634 4350 before attempting to use this monitor For specific information about your own blood pressure consult with your physician Intended Use This device is a digital monitor intended for use in meas...

Page 4: ...lt in incorrect operation of the monitor and or cause an inaccurate reading DO NOT use this monitor in oxygen rich environments or near flammable gas Consult with your physician before using this moni...

Page 5: ...injury Consult with your physician before using this monitor if you have had a mastectomy Consult with your physician before using this monitor if you have severe blood flow problems or blood disorde...

Page 6: ...nment within the temperature specified as operating conditions after it is stored either at the maximum or at the minimum storage temperature For additional information on operating and storage transp...

Page 7: ...g this monitor Battery Handling and Usage DO NOT insert batteries with their polarities incorrectly aligned ONLY use 4 AA alkaline or manganese batteries with this monitor DO NOT use other types of ba...

Page 8: ...storage case instruction manual quick start guide 1 2 Monitor and Arm Cuff Front of the monitor Left and right side of the monitor Display Memory button Morning average button Forward Backward buttons...

Page 9: ...8 1 Know Your Monitor Back and bottom of the monitor Arm cuff Upper arm circumference 9 17 22 42 cm Connection button Date Time Battery compartment Air plug Air tube i j i j k k l l...

Page 10: ...mbol Systolic blood pressure reading Date Time display Comparison display High symbol High morning average symbol Pulse display Memory number OK symbol Diastolic blood pressure reading Movement error...

Page 11: ...od pressure reading Comparison display Displays past readings Refer to section 5 for more information Pulse display Memory number Pulse rate appears after the measurement When pressing the button the...

Page 12: ...he oldest reading Up to 60 readings can be stored in the internal memory of your monitor per user Low battery symbol Flashes when batteries are low Depleted battery symbol Appears when batteries are d...

Page 13: ...below Irregular heartbeat is detected 2 times Irregular heartbeat is detected 3 times or more An irregular heartbeat rhythm is defined as a rhythm that is 25 less or 25 more than the average rhythm d...

Page 14: ...ur physician BP Category Systolic BP Diastolic BP Normal 120 mmHg and 80 mmHg Elevated 120 129 mmHg and 80 mmHg Hypertension Stage 1 130 139 mmHg or 80 89 mmHg Stage 2 140 mmHg or 90 mmHg Individuals...

Page 15: ...time manually or refer to sub section 4 1 to pair your monitor to set the date and time automatically Note When the symbol flashes on the display it is recommended you replace batteries To replace ba...

Page 16: ...ct US CAN app Refer to sub section 4 1 As soon as batteries are correctly installed the year flashes on the display of your monitor 1 If nothing is displayed press the button rear surface of the monit...

Page 17: ...e button to store the setting Your monitor automatically turns off 3 seconds after the minutes have been set in this sequence Note If you need to reset the date and time replace batteries or press the...

Page 18: ...Taking measurements in the morning and in the evening is recommended Remember to have a record of your blood pressure and pulse readings for your physician A single measurement does not provide an ac...

Page 19: ...d pressure can differ between the right arm and the left arm and the measured blood pressure readings can be different OMRON recommends to always use the same arm for measurement If the readings betwe...

Page 20: ...edge of the arm cuff should be 0 5 inch 1 to 2 cm above the inside elbow The air tube is on the inside of your arm and aligned with your middle finger 3 Make sure that the air tube is positioned on t...

Page 21: ...To take a measurement on your right arm When you take a measurement on your right arm the air tube should run along the side of your elbow along the bottom of your arm Be careful not to rest your arm...

Page 22: ...ortable chair with your back and arm supported Keep your feet flat and your legs uncrossed The arm cuff should be placed on your arm at the same level as your heart with the arm resting comfortably on...

Page 23: ...he monitor and or cause an inaccurate reading Remain still and DO NOT talk while taking a measurement 1 Press the START STOP button All symbols appear on the display before starting the measurement 2...

Page 24: ...e the wait time depending on your individual physiological characteristics Using the Guest Mode Your monitor stores readings for 2 users in the memory The guest mode can be used to take a single measu...

Page 25: ...mHg take a measurement manually After the arm cuff starts to inflate press and hold the START STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure Note Do n...

Page 26: ...ll the free OMRON connect US CAN app onto your smart device If you already have the OMRON connect US CAN app and have created your account open the app and add your new monitor 3 Open the app and foll...

Page 27: ...tion in the app OMRON connect US CAN is the only app that we recommend to use with your monitor to transfer data correctly 4 2 Taking a Measurement Refer to sub section 3 1 to start a measurement Open...

Page 28: ...s For further information on potential restrictions refer to documentation on the Bluetooth usage by the FCC ISED Bluetooth is enabled as default 1 When your monitor is off press and hold the button r...

Page 29: ...with a past reading A past reading will appear in the comparison display on the left Note If the reading is high refer to sub section 1 3 the symbol appears If there are no readings stored in the memo...

Page 30: ...your monitor to the correct date and time before taking a measurement to view the average readings 1 Select your user ID 2 When your monitor is off press and hold the button for more than 3 seconds Th...

Page 31: ...ge readings Morning Weekly Average Calculation This is the average for the measurements taken during the morning 4 00 am 9 59 am between Sunday and Saturday The 2 or 3 readings taken within the first...

Page 32: ...on the left If the morning weekly average is high refer to sub section 1 3 the or symbol appears 3 Press the or button repeatedly to scroll through the previous readings stored in the memory Your moni...

Page 33: ...the latest reading will appear with a past reading 3 While holding the button down press and hold the START STOP button for more than 3 seconds The display to the right flashes 4 While holding the bu...

Page 34: ...Settings To delete all the information stored in your monitor follow the instructions below Make sure that your monitor is turned off 1 While holding the button rear surface of the monitor down press...

Page 35: ...the completion the year flashes on the display Refer to sub section 2 2 to set the date and time manually or refer to sub section 4 1 to pair your monitor to set the date and time automatically Revert...

Page 36: ...er measurement Refer to sub section 2 4 Air is leaking from the arm cuff Replace the arm cuff with a new one Refer to section 9 appears or a measurement cannot be complete after the arm cuff inflates...

Page 37: ...t Remain still and do not talk during a measurement appears The pulse rate is not detected correctly Apply the arm cuff correctly then take another measurement Refer to sub section 2 4 Remain still an...

Page 38: ...START STOP button to cancel pairing and turn your monitor off flashes The monitor is ready to transfer your readings to the smart device Open the OMRON connect US CAN app to transfer your readings fla...

Page 39: ...ress time of day and or how you apply the arm cuff may affect your blood pressure Review sub sections 2 3 2 5 and section 3 Any other communication issue occurs Follow the instructions shown in the sm...

Page 40: ...and other components in the storage case when not in use Store your monitor and other components in a clean safe location 1 Remove the arm cuff from the monitor Caution To unplug the air plug pull on...

Page 41: ...or immerse your monitor and arm cuff or other components in water Do not use gasoline thinners or similar solvents to clean your monitor and arm cuff or other components 8 4 Disposal Dispose of your m...

Page 42: ...nformation visit our website at OmronHealthcare com Small D Ring Cuff Wide Range D Ring Cuff Arm circumference 7 9 17 22 cm Arm circumference 9 17 22 42 cm Model HEM CS24 B HEM CS24 BZ Model HEM RML31...

Page 43: ...eset the date and time each time you unplug and plug back the AC adapter The readings will not be deleted 1 Insert the AC adapter plug into the AC adapter jack on the right side of your monitor 2 Plug...

Page 44: ...communication Frequency range 2 4 GHz 2400 2483 5 MHz Modulation GFSK Effective radiated power 20 dBm Operation mode Continuous operation IP classification Monitor IP20 Optional AC adapter IP21 Ratin...

Page 45: ...apter is protected against vertically falling water drops which may cause issues during a normal operation Weight Monitor Approximately 16 2 oz 460 g not including batteries Arm cuff Approximately 6 o...

Page 46: ...this product is used near other wireless devices such as microwave and wireless LAN which operate on the same frequency band as this product there is a possibility that interference may occur If inter...

Page 47: ...ecifications Pictogram on the Product or Types of marks used to indicate the correct positioning of the artery for the upper arm Identifies the type of cuff that is compatible with the blood pressure...

Page 48: ...erference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interfe...

Page 49: ...with FCC ISED radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency RF Exposure Guidelines and RSS 102 of the ISED radio frequency RF Exposure rules as...

Page 50: ...ing and handling fee that may apply Enclose the original printed receipt Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prev...

Page 51: ...may have other rights that vary by jurisdiction Because of special local requirements some of the above limitations and exclusions may not apply to you FOR CUSTOMER SERVICE Visit our web site at For...

Page 52: ...ocumentation in accordance with this EMC standard is available at OmronHealthcare com emc Refer to the EMC information for BP5350 on the website The Bluetooth word mark and logos are registered tradem...

Page 53: ...52 Notes...

Page 54: ...ARE Co Ltd 53 Kunotsubo Terado cho Muko Kyoto 617 0002 JAPAN Distributed by OMRON HEALTHCARE INC 1925 West Field Court Lake Forest IL 60045 U S A For USA OmronHealthcare com For Canada OmronHealthcare...

Reviews: