App-1
Appendix-1 Parameter List
Appe
ndix
AppAppendix
Appendix-1 Parameter List
Monitor Mode (d
)
• The default setting displays "d001" at power-on. To select the optional display, change the setting
in "b038".
Parameter
No.
Function name
Monitor or data range
Default
setting
Changes during
operation
Unit
Page
Normal b031 = 10
d001
Output frequency
monitor
0.0 to 400.0
⎯
Yes
⎯
Hz
d002
Output current
monitor
0.0 to 999.9
1000 to 9999
⎯
⎯
⎯
A
d003
Rotation direction
monitor
F: Forward
o: Stop
r: Reverse
⎯
⎯
⎯
⎯
d004
PID feedback value
monitor
0.00 to 99.99
100.0 to 999.9
1000. to 9999.
1000 to 9999 (10000 to 99990)
⎡
100 to
⎡
999 (100000 to 999000)
(Enabled when the PID function is selected)
⎯
⎯
⎯
⎯
d005
Multi-function input
monitor
⎯
⎯
⎯
⎯
d006
Multi-function
output monitor
⎯
⎯
⎯
⎯
d007
Output frequency
monitor
(after conversion)
0.00 to 99.99
100.0 to 999.9
1000. to 9999.
1000 to 3996 (10000 to 39960)
(Output frequency × Conversion factor of b086)
⎯
Yes
⎯
⎯
d008
Real frequency
monitor
-400. to -100.
-99.9 to 0.00 to 99.99
100.0 to 400.0
⎯
⎯
⎯
Hz
d009
Torque reference
monitor
-200. to +200.
⎯
⎯
⎯
%
d010
Torque bias
monitor
-200. to +200.
⎯
⎯
⎯
%
d012
Output torque
monitor
-200. to +200.
⎯
⎯
⎯
%
d013
Output voltage
monitor
0. to 600.
⎯
⎯
⎯
V
FW
S8 S7 S6 S5 S4
S3 S2 S1
(Example) Terminals FW, S7, S2, S1 : ON
Terminals S8, S6, S5, S4, S3: OFF
MA
P5 P4
P3 P2 P1
(Example) Terminals P2, P1 : ON
Terminals MA, P5, P4, P3: OFF
Summary of Contents for 3G3RX Series
Page 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Page 2: ......
Page 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Page 22: ......
Page 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Page 48: ......
Page 108: ......
Page 324: ......
Page 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Page 348: ......
Page 392: ......
Page 436: ......
Page 437: ...Index ...
Page 441: ......