3-2
3-1 Parameter Description of Each Function
3
Funct
ions
BCD Batch Input
The settings of frequency, torque limit and position can be selected using the rotary switch (CODE)
in a single data input.
The data bit configuration of the BCD batch input is shown below.
Setting Example
When setting the frequency to 30.00 Hz with a resolution of 0.01 Hz (Rotary switch setting (CODE):
0)
1. Input the 16-bit BCD value of 30 multiplied by 100 in terminals D15 to D0.
30
×
100 times = 3000
→
0011000000000000 (binary)
2. When the data is entered, turn the strobe signal ON.
3. Turn the strobe signal OFF.
Precautions
For details on signal input timing, refer to "3-3 Data Input Timing"(Page 3-6).
DIP switch TYPE setting
1
2
ON: BCD
OFF: PAC
D11 D10
D 9
D8
D7
D6
D5
D4
D3
D2
D1
D0
D15 D14 D13 D12
(MSB)
(LSB)
Set data 4
Set data 3
Set data 2
Set data 1
0
0
0