2JCIE-BL01-P1 Environment Sensor (PCB Type) User’s Manual (A280)
27
2.4.2
ADV setting
(Characteristics UUID: 0x3042)
Set various Advertisement related parameters.
Time Information is cleared to zero (0) when Beacon Mode is changed, so Time Information must be
set to start data recording again.
*After changing the settings of this characteristic, it is necessary to make power cycle.
* It makes difficult to establish a connection with the central device in a very short “Transmission
period in Limited Broadcaster” setting.
Table 32. ADV setting format
Byte
Field
Format
Contents
0
ADV_IND
Advertise interval
L
UInt16
Advertise interval
Unit
:
0.625ms
Range
:
0x0320(500ms)
~
0x4000(10.24s)
Default
:
0x0808 (1285ms)
1
H
2
ADV_NONCON_IND
Advertise interval
L
UInt16
Unit
:
0.625ms
Range
:
0x00A0(100ms)
~
0x4000(10.24s)
Default
:
0x00A0 (100ms)
*Not used
3
H
4
Transmission period
in Limited Broadcaster
L
UInt16
Set transmission period per cycle when
Beacon Mode 0x03,0x05 Limited Broadcaster
Unit
:
1 sec
Range
:
0x0001(1s)
~
0x3FFF(16383s)
Default
:
0x000A (10s)
5
H
6
Silent period
in Limited Broadcaster
L
UInt16
Set silent period per cycle when
Beacon Mode 0x03,0x05 Limited Broadcaster
Unit
:
1 sec
Range
:
0x0001(1s)
~
0x3FFF(16383s)
Default
:
0x0032 (50s)
7
H
8
Beacon Mode
UInt8
Range
:
0x00(0)
~
0x0A(10)
Default
:
0x08 (8)
*Refer to Table 33. Beacon Mode for details
9
Tx Power
SInt8
Unit
:
dBm
Range
:
-20, -16, -12, -8, -4, 0, 4 dBm
Default
:
0x00 (0 dBm)