Omnitronix Data-Link DL30 Installation And Operation Manuallines Download Page 24

2005 Omnitronix, Inc. 

 

24

Warranty Information 
 

Omnitronix, Inc. hereby warrants that it will, as the buyers sole remedy, repair or replace, at its 
option, any part of the DL30 which proves to be defective by reason of improper materials or 
workmanship, without charge for parts or labor, for a period of 12 (twelve) months.  This warranty 
period commences on the date of first retail purchase, and applies only to the original retail 
purchaser. 
 
To obtain service under this warranty, you must obtain, by telephone, postal letter, or email, a 
return authorization number from Omnitronix Technical Support.  This authorization number may 
be obtained by contacting Omnitronix Technical Support at the address and/or phone number 
below.  The defective unit is to be returned to Omnitronix with shipping prepaid, and the return 
authorization number must be clearly marked on the outside of the package containing the 
defective unit. 
 
The dealer's bill of sale or other satisfactory proof of the date of purchase may be required to be 
presented in order to obtain service under this warranty. 
 
This warranty applies if your DL30 fails to function properly under normal use and within the 
manufacturer's specifications.  This warranty does not apply if, in the opinion of Omnitronix, Inc., 
the unit has been damaged by misuse, neglect, improper packing, shipping, modification, or 
servicing by other than Omnitronix or an authorized Omnitronix Service Center. 
 
In no event shall Omnitronix, Inc. be liable for any loss, inconvenience or damage, whether direct, 
incidental, consequential or otherwise, with respect to the DL30.  Omnitronix, Inc.'s liability shall 
be limited to the purchase price of the DL30.  No warranty of fitness for purpose or of fitness of 
the DL30 for any particular application is provided.  It is the responsibility of the user to determine 
fitness of the DL30 for any particular application or purpose. 
 
This warranty gives you specific legal rights.  These rights may vary from state to state, as some 
states do not allow limitations on liability. 
 
You may request information on how to obtain service under this warranty by contacting 
Omnitronix Technical Support.

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Data-Link DL30

Page 1: ...DL30 Pollable Remote Access Unit Installation and Operation Guidelines Manual Rev 1 00...

Page 2: ...e content of this manual is provided for informational use only and is subject to change without notice Examples data and names used in this manual are examples and fictitious unless otherwise noted N...

Page 3: ...Collection and Storage Polling Remote Access Pass through Data Alarm Monitoring Alarm Notification OmniAlarms Status Screen 13 Setup Menu 14 Option Types General Settings Network Settings Serial Setti...

Page 4: ...end of the DB9 cable to Output port of the DL30 and the other end into a serial comm port of the computer with terminal emulation software 2 Connect the power supply cord into the DL30 and the transfo...

Page 5: ...0 are not case sensitive You should be presented with the Status screen which looks similar to the following Data Link DL30 1 00 STD Unit Serial 1030331E ID Data Link I O1 Baud Rate 19200 Date TUE 08...

Page 6: ...ing methods depending on the hardware configuration Serial or modem connection to command processor using Line or Zmodem or pass through Telnet to command processor or pass through Inline Mode data in...

Page 7: ...D indicates the file database has less than the amount indicated by that LED but more than the previous A solid lit LED indicates the file database percentage is at or over the value for that LED Link...

Page 8: ...0BaseT connector if installed is an RJ 45 Connect a network cable from an Ethernet hub or switch to this port Internal Modem The 33K internal modem connector if installed is an RJ 11 Connect a POTS an...

Page 9: ...N OFF 1200 OFF ON ON 1200 OFF ON ON 2400 ON OFF OFF 2400 ON OFF OFF 4800 ON OFF ON 4800 ON OFF ON 9600 ON ON OFF 9600 ON ON OFF 19200 ON ON ON 19200 ON ON ON Word Parity Stop SW4 SW5 Word Parity Stop...

Page 10: ...d via FTP in one of two ways 1 FTP push the DL30 can be configured in the Network Settings menu to push the data in File 1 to an FTP server at specific intervals Once the remote host has received the...

Page 11: ...ceiver the DL30 will send a message similar to the following Data Link DL30 Server Room B Omnitronix Alarm Notice ver 1 00 CR LF ENQ The first line of the output is the DL30 answer string The second l...

Page 12: ...of each alarm delivered during a call This number restarts at 1 for each new call The severity line represents the Class value defined for this alarm Up to twelve lines of Textn may be sent XX represe...

Page 13: ...alled that is currently occupied by serial port data or alarm records Modem and Network indicate whether or not that component is installed in the DL30 via either YES or NO If a network interface is i...

Page 14: ...a setting s value 2 The second most common option type is the toggle type option E Wrap Around ON When selected this option will not prompt for a new value It will simply cycle to the next available o...

Page 15: ...ne hour at 2 00 a m local standard time which becomes 3 00 a m local daylight time On the last Sunday in October clocks are set back one hour at 2 00 a m local daylight time which becomes 1 00 a m loc...

Page 16: ...inutes Between Push Attempts 1 to 9999 minutes Note This manual refers to FTP get and push frequently FTP get is defined as any user or process accessing the DL30 via FTP in order to fetch records or...

Page 17: ...can also be configured via dips switch SW12 Inline Mode Handshaking Determines what methods can be used to control the release of records in Inline mode Xon Xoff to start and stop record release or DT...

Page 18: ...2005 Omnitronix Inc 18 This is the menu where up to twenty individual alarm strings can be entered Data Link DL30 Data Alarm Strings A B C D E F G H I J K L M N O P Q R S T Enter your Selection...

Page 19: ...status screen STATUS or Display the status screen Data Release Commands Command Summary Syntax Description CLEAR Clear released data CLEAR Delete released records in the active file COUNT Count recor...

Page 20: ...P address Subnet mask Router address Serial port baud rate and data format Data alarm fields Data alarm settings Does not affect record data FTEST Test flash memory FTEST Destructive test of CRDB flas...

Page 21: ...the modem causes harm to the telephone network the telephone company may temporarily discontinue your service If possible they will notify you in advance If advance notification is not possible you wi...

Page 22: ...percentage of total load to be connected to a telephone loop which is used by the device to prevent overloading The termination of a loop may consist of any combination of devices subject only to the...

Page 23: ...vior recours a un service d inspection des installations lectriques ou a electricien selon le cas L indice de charge IC assign a chaque dispositif terminal indique pour viter toute surcharge le pource...

Page 24: ...e date of purchase may be required to be presented in order to obtain service under this warranty This warranty applies if your DL30 fails to function properly under normal use and within the manufact...

Reviews: