Omnitronic CU-200 SP User Manual Download Page 3

www.omnitronic.com

00053192.DOC, Version 1.2

CONFERENCE SPEAKER UNIT

USER MANUAL

CU-200 SP DU-200 SP

I

Conference Speaker Unit

The chairman speaker unit

and the delegate speaker unit

are gooseneck

condenser microphones with hypercardioid characteristic and are specially designed for use with the

conference amplifier

. The amplifier offers connections for up to 60 speaker units and supplies

them with power. Delivery includes a windscreen.

Connect the connection cable of the first speaker unit with one of the speaker unit inputs GROUP 1 to 4 on the

conference amplifier. Then connect the connection cable of the second speaker unit to the feed-through jack of

the first speaker unit, etc. until all speaker units are interconnected to a row (max. 20 units). Repeat the steps

for the other speaker unit inputs GROUP 1 to 4 correspondingly. The speaker units can be connected within

the chain as desired. f required, extension cables available in 5 and 10 m can be used. The total cable length

from the conference amplifier to the last speaker unit must not exceed 180 m.

Adjust the gooseneck on the speaker unit so that the microphone points directly to the speaker. Place the

supplied windscreen.

Adjust the volume on the speaker unit with the control LEVEL.

The sum signal of the conference system can also be monitored via two sets of stereo headphones

connected to the jacks EARPHONES 1 and 2. The headphones level is determined by the setting of the

control LEVEL.

Switch on the microphone of the delegate speaker unit

with one of the on/off switches. The

conference amplifier registers the request to speak and the speaker unit is allocated a free transmission

channel. The light ring on the gooseneck and the LED next to the on/off switches light up red to indicate that

speaker unit can now be used to make announcements.

The number of delegate speaker units that can be used simultaneously depends on the operating mode

adjusted with the control

on the conference amplifier:

operating mode closed user group: If the maximum number is reached when switching on a further speaker

unit its function indicator will flash green and the conference amplifier does not allocate a free transmission

channel. Then a speaker unit must be switched off first before another unit can be switched on.

operating mode open user group: If the maximum number is reached when switching on a further speaker

unit all other speaker units are automatically switched off.

In order to switch on the microphone of the chairman speaker unit

press the button MIC. The

light ring and the function LED light up red, and the speaker unit is allocated a free transmission channel by

the conference amplifier regardless of the operating mode adjusted for the delegate units.

The chairman speaker unit can take priority over the other speaker units. For this press the button PRIORITY.

Then all delegate speaker units will be switched off.

Type:.............................Condenser/hypercardioid

Frequency range:..........100 Hz - 16 kHz

Impedance:...................600

Sensitivity: ....................-44 dB

Power supply: ...............1.5 V DC , 0.5 mAvia microphone line

Max. operating voltage: .10 V

Connections:.................1 x 8-pin DIN plug/1 x 8-pin DIN jack (microphone line)

......................................2 x 3.5 mm jack (headphones, min. 4 )

Speaker type: ................Full-range

Dimensions:..................150 x 130 x 60 mm

Weight:..........................800 g

CU-200 SP

DU-200 SP

CPA-5200

DU-200 SP

CU-200 SP

Setting into Operation

Operation

Technical Specifications

Ÿ

Ÿ

Ÿ

Ÿ

Ÿ

Ÿ

Ÿ

Ÿ

Ÿ

W

W

Please note: Every information is subject to change without prior notice.

©

01.05.2010

Reviews: