Page 5

Front Panel Layout

Serial Console Port   

To  configure  the  module  using  the  serial  port,  attach  a  DB-9  serial  (RS-232) 

equipped computer with terminal emulation software such as Procomm or Putty 

to the serial port on the module using a RJ-45 to DB-9 serial cable (not included).  

Some computers do not come with DB-9 serial port connectors and may require a 

USB-to-serial port adapter. 
The port is a standard RS-232 asynchronous serial interface.  The serial ports is 

configured for 57,600bps, 1 stop, 8 data, parity none.  The serial adapter cable 

pin-outs are illustrated below.

Standard RJ-45 to DB-9 serial cable pin-out

Reset Button   

A reset button is available on the front of the module to restore the module to factory 

default values.  Press and hold the reset button for more than 5 seconds to restore 

the module to factory default values.

Page 6

Installation Procedure

1) Configure DIP-switches

2) Installing the Module
3) Apply Power
4) Connect Cables
5) Verify Operation

1) Configure DIP-switches

DIP-switches are located on the side of the OmniConverter G/M.  The DIP-switches 

are used to configure modes of operation and networking features. 

DIP-switch Bank Locations

The table below provides a description of each DIP-switch position and function.

Switch

1 Uplink Port 

2 Uplink Ports

SW1

Reserved

Device Mode

SW2

Switch Mode

SW3

Reserved

Uplink Redundancy

SW4

Reserved

SW5

MAC Learning

SW6

Pause

SW7

L2CP

SW8

Reserved

DIP-switch Definitions

Summary of Contents for OmniConverter G/M

Page 1: ...can be extended to five 5 years by registering the product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option r...

Page 2: ...ssible DIP switches or using Web Telnet SSH SNMPv1 v2c v3 or Serial Console management interfaces These management interfaces provide access to filtering and security options such as broadcast storm p...

Page 3: ...set Button A reset button is available on the front of the module to restore the module to factory default values Press and hold the reset button for more than 5 seconds to restore the module to facto...

Page 4: ...configured for Directed Switch Mode traffic from all the RJ 45 user ports is only forwarded to the uplink port F1 preventing the broadcast traffic from flooding other network ports Incoming traffic f...

Page 5: ...P Redundant Mode return to primary F1 Uplink Redundancy Page 10 When configured for Uplink Redundant Mode no return to primary the uplink ports operate as redundant links A fault on the primary Port F...

Page 6: ...LED located on the front of the switch AC Models Rear View Barrel Connector for AC DC Power Adapter NEVER ATTEMPT TO OPEN THE CHASSIS OR SERVICE THE POWER SUPPLY OPENING THE CHASSIS MAY CAUSE SERIOUS...

Page 7: ...re isolated This provides support of positive or negative power connections Power Options WARNING Note the wire colors used in making the positive negative and ground connections Use the same color as...

Page 8: ...g at 1Hz Port linked at 100Mbps and in redundant secondary mode Amber Blinking at 1Hz Port linked at 100Mbps and receiving Far End Fault Indicator FEFI 1000 OFF No link Green ON Port linked at 1000Mbp...

Page 9: ...Fiber Fixed ST SC LC 1000BASE X Fiber SFP 10 100 1000BASE T SGMII Copper Transceiver or 1000BASE X Fiber Transceiver Serial RJ 45 RS 232 Cable Types Copper EIA TIA 568A B Cat 5 UTP and higher Fiber M...

Page 10: ...s product contact Omnitron Technical Support Phone 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 38 Tesla Irvine CA 92618 USA Email support omnitron systems com URL www omnitro...

Reviews: