WARNING:
Only a DC power source that complies with
safety extra low voltage (SELV) requirements can be
connected to the DC-input power supply.
WARNING REGARDING EARTHING GROUND:
o
o
o
o
This equipment shall be connected to the DC supply
system earthing electrode conductor or to a bonding
jumper from an earthing terminal bar or bus to which the
DC supply system earthing electrode is connected.
This equipment shall be located in the same immediate
area (such as adjacent cabinets) as any other equipment
that has a connection between the earthed conductor of
the same DC supply circuit and the earthing conductor,
and also the point of earthing of the DC system. The DC
system shall not be earthed elsewhere.
The DC supply source is to be located within the same
premises as this equipment.
There shall be no switching or disconnecting devices in
the earthed circuit conductor between the DC source and
the earthing electrode conductor.
Locate the DC circuit breaker of the external power source, and switch the circuit
breaker to the OFF position.
Prepare a power cable using a three conductor insulated wire (not supplied) with
12AWG to 14AWG thickness. Cut the power cable to the length required.
Strip approximately 3/8 of an inch of insulation from the power cable wires.
Connect the ground wire to the NEBS grounding screws on the back of the module.
Route the power cables through the provided strain relief for additional support.
Connect the power cables to the module by fastening the stripped ends to the DC
power connector.
WARNING: Note the wire colors used in making the positive, negative and ground
connections. Use the same color assignment for the connection at the circuit breaker.
Connect the power wires to the circuit breaker and switch the circuit breaker ON.
If any module are installed, the Power LED will indicate the presence of power.
During the installation, ensure that the ground potentials are maintained throughout
the system connections. This includes but not limited to the power source ground
and any shielded cabling grounds.
Installation of the equipment should be such that the air flow in the front, back, side
and top vents of the chassis are not compromised or restricted.
Page 12
Rear View with AC Power Connector
NEVER ATTEMPT TO OPEN THE CHASSIS OR
SERVICE THE POWER SUPPLY. OPENING THE
CHASSIS MAY CAUSE SERIOUS INJURY OR DEATH.
THERE ARE NO USER REPLACEABLE OR
SERVICEABLE PARTS IN THIS UNIT.
WARNING!!!
DC Power
This module is intended for installation in restricted access areas. (“Les matériels
sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT”).
A restricted access area can be accessed only through the use of a special key, or
other means of security.
The over current protection for connection with centralized DC shall be provided in
the building installation, and shall be a UL listed circuit breaker rated 20 Amps, and
installed per the National Electrical Code, ANSI/NFPA-70.
Appropriate overloading protection should be provided on the DC power source
outlets utilized.
The FPoE/S requires 46 to 57VDC @ 0.79 Amp max rated power. The FPoE+/S
requires 52 to 57VDC @ 1.37 Amp max rated power (see Specification table for
specific model requirements).
Description
IEEE 802.3af PoE
IEEE 802.3at PoE+
Power Supply Voltage Range
46.0 to 57.0 VDC
51.0 to 57.0 VDC
Voltage Range at PSE port Output
44.0 to 56.0 VDC
50.0 to 56.0 VDC
Maximum Power from PoE/PSE port
15.4 watts
30 watts
Minimum Voltage at PoE/PD port input*
37.0 VDC
42.5 VDC
Minimum Power at PoE/PD port*
12.95 watts
25.5 watts
* at 100 meters using Cat5
Page 11