iConverter
10/100M2 Plug-in Module QUICK START GUIDE
The
iConverter
®
10/100M2 is a carrier-class media converter and
a Network Interface Device (NID) that provides 10BASE-T or
100BASE-TX (10/100) to 100BASE-FX Fiber media conversion
with integrated management.
The 10/100M2 has built-in Operation, Administration and
Maintenance (OAM) functionality enabling the 10/100M2 to operate
as a managed demarcation point at the customer premises and
network edge, offering Quality of Service capabilities.
The 10/100M2 module can be managed using
NetOutlook
®
SNMP
Management Software, Telnet or the Command Line Interface
(CLI).
For the complete User Manual on this product, access Omnitron’s
secure download site and request access.
http://www.omnitron-systems.com/login.php
InSTAllATIon PRoCEDURE
1) Configure DIP-Switches
2) Install Module in Chassis and Connect Cables
3) Configure Module via Command Line Interface
4) Verify Operation
1) ConFIGURE DIP-SwITChES
DIP-SwITCh BAnK 1
Sw1 - UTP/FIBER PAUSE EnABlE
When this DIP-switch is in the Left “OFF” position,
Pause is disabled. When the DIP-switch is in the
Right “PAUS” position Pause is enabled.
When a port is configured for Auto-Negotiation
(AN), Pause operation is determined during the
negotiation process between itself and the link
partner. The port advertises its Pause capability
(Symmetrical or No Pause) based on the Pause
Disable/Enable DIP-switch setting.
When a port is operating in Manual mode (MAN),
its Pause operation mode is based on the Pause
Disable/Enable DIP-switch setting.
Sw2 - FIBER FUll/hAlF DUPlEX
Setting this DIP-switch to Half-Duplex “HDX”
facilitates a connection that supports Half-Duplex.
Setting this DIP-switch to Full-Duplex “FDX”
facilitates a connection that supports Full-Duplex
operation.
Once connected, press <
ENTER
> to bring up a command line prompt on the attached
PC.
Management Options
iConverter, Serial Agent
Network Management
1: Chassis and Module Management
2: Set Module Name Preferences
Management Module Preferences
3: IP and Control Preferences
4: SNMP Preferences
5: Abandon Preference Changes
6: Save Preference Changes
7: Restore Factory Defaults
8: Restart Management Module
9: Other Networking Features
Management Module Maintenance
10: Firmware Update
11: Set Date/Time
IP Address = 192.168.1.220
Chassis Number = 1
Enter Choice, <H>elp, E<x>it >
Figure E: Command Line Interface Menu Options
The CLI interface allows for the detailed configuration of the module. It is recommended
to configure the module with an IP address associated with the attached network.
Also, SNMP traphost address should be configured if the module is managed with an
SNMP-based Management System. See the 10/100M2 User Manual for complete
information.
4) VERIFy oPERATIon
Once the module has been
installed and configured per
steps 1 - 3, verify the module is
operational by viewing the LED
indicators.
The Power LED indicates the
modules is receiving power from
the chassis.
The Fiber Optic link LED indicates
the fiber optic connection has
been established.
The UTP link LED indicates
the module has established
a connection across its UTP
port.
Figure A: DIP-Switch Locations
Form 040-8900N-002 C 9/10
Omnitron Systems Technology * 140 Technology Dr. #500 * Irvine, CA 92618
949.250.6510 tel * 949.250.6514 fax * www.omnitron-systems.com
Figure F: LED Indicators
Page 1
lED Function
“legend”
Color
oFF State
on / Blinking State
Power “Pwr”
Green
No power
Module has power
Power Supply
Status “PSx”
Green
Power Supply not
installed
ON: Power Available
Blinking: No power available
from “PSx”
Network Ports Status*
Fiber Optics “FO”
Green
No Fiber Link
ON: Fiber link is active
Blinking: Fiber Data Activity
Master/Slave “BP”
Green
Slave Mode
Master Mode
10Mbps UTP “10”
Green
10Mbps not selected or
disconnected
ON: Active 10Mbps UTP link
Blinking: UTP Data Activity
100Mbps UTP
“100”
Green
100Mbps not selected
or disconnected
ON: Active 100Mbps
UTP link
Blinking: UTP Data Activity
UTP Full-Duplex
“FDX”
Green
Half-Duplex
Full-Duplex