Omnitron Systems Technology OmniConverter 10GPoEBT/M Quick Start Manual Download Page 5

Page 9

store the address so packets destined for the stored addresses can be forwarded to 

the appropriate port on the module. When the DIP-switch is in the UP “Off” position, 

learning is turned off and all received unicast packets are forwarded to all ports.

SW6: Forced PoE - “Off/ PoE Forced”

This DIP-switch allows the PoE power to be forced ON when connected to a PD 

with non-standard detection characteristics. The DIP-switch controls the forced 

capability for the RJ-45 user ports on the module.

When  this  DIP-switch  is  in  the  DOWN  “Off”  position,  all  RJ-45  user  ports  will 

automatically perform the detection, classification and powering functions for the 

attached PD. When this DIP-switch is in the UP “PoE Forced” position, all RJ-45 

user ports will provide a maximum of 60 or 100 watts of power (depending on the 

model) to the PD. 

SW7: L2CP - “L2CP Tunnel/Discard”

When this DIP-switch is in the DOWN “L2CP Tunnel” position (factory default), all 

L2CP frames will be tunneled through the module.  When this DIP-switch is in the 

UP “Discard” position, all L2CP frames will be discarded.

SW8:  PSE Reset - “Off/PoE Reset”

The module can be configured to disable (reset) the PoE output power for 5 seconds 

after a loss of receive link on any uplink port.  This feature is typically used to allow 

a PD to re-initialize after a failure on the incoming uplink.  

When this DIP-switch is in the DOWN “Off” position (factory default), PoE output 

power does not reset on a loss of receive link on any uplink port.  When this DIP-

switch is in the UP “PoE Reset” position, the module will disable PoE output power 

for 5 seconds following a loss of receive link on any uplink port.  
When uplink redundancy is enabled, the loss of link on either F1 or F2 will not cause 

the PD to be re-initialized even though the PSE Reset is enabled.  The PD will be 

re-initialized on a loss of receive link on both uplink ports.
When Dual Device Mode is enabled, the loss of receive link on a uplink port will 

re-initialize the PDs associated with the that uplink port.  Ports P1 and P2 will drop 

PoE power when a loss of receive link on F1 is detected and ports P3 and P4 will 

drop PoE power when a loss of receive link on F2 is detected.  

2) Installing the Module

Wall Mounting

The wall mounting height of the module should be less than or equal to 2 meters 

(6.6 feet) from the floor.  Use the four mounting holes on the module to secure the 

module to the wall.  The module can accommodate #6 screws (not included).

Installation of the module should be such that the air flow in the front, back, side 

and top vents of the switch are not compromised or restricted.
The accessory cables should have their own strain relief and do not pull down on 

the module. 

Page 10

Rack Mounting

The module can be rack mounted using the optional Rack Mount Shelf (8260-0).  

Refer to the Rack Mount Shelf user manual (040-08260-001x) for the proper 

installation guidelines.
Follow the same guidelines above when rack mounting the module.

3) Apply Power

AC Power

Secure the ground wire to the ground screw.  See the figure below for the location 

of the grounding screws.
Route the power cord through the provided strain relief for additional support and  

connect the DIN connector at the end of the wire on the AC/DC adapter to the DIN 

connector on the module.  Connect the AC/DC adapter to the AC outlet.  Confirm 

that the module has powered up properly by checking the Power LED located on 

the front of the switch.

AC Models Rear View: DIN Connector for AC/DC Power Adapter

Make sure to disconnect the power and ground cables before removing the module.

NEVER ATTEMPT TO OPEN THE CHASSIS OR

SERVICE THE POWER SUPPLY. OPENING THE

CHASSIS MAY CAUSE SERIOUS INJURY OR DEATH.

THERE ARE NO USER REPLACEABLE OR

SERVICEABLE PARTS IN THIS UNIT.

WARNING!!!

DC Power

This module is intended for installation in restricted access areas. (“Les matériels 

sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT”). 

A restricted access area can be accessed only through the use of a special key, or 

other means of security.
The over current protection for connection with centralized DC shall be provided in 

the building installation, and shall be a UL listed circuit breaker rated 20 Amps, and 

installed per the National Electrical Code, ANSI/NFPA-70.
The 10GPoEBT/M (60W models) re50 to +57VDC inclusive of tolerances 

(4.47A @ 56VDC max rated power) and the 10GPoEBT/M (100W models) requires 

+52 to +57VDC inclusive of tolerances (7.33A @ 56VDC max rated power). See 

specification table for specific model requirements. 

Summary of Contents for OmniConverter 10GPoEBT/M

Page 1: ...adapter can be extended to five 5 years by registering the product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its...

Page 2: ...1000 RJ 45 copper Power Sourcing Power over Ethernet user ports The 10GPoEBT M is an IEEE 802 3bt compliant PoE switch featuring 60W and 100W per user port The mode of operation can be configured usi...

Page 3: ...hes are located on the side of the module The DIP switches are used to configure modes of operation networking features and PoE reset Page 6 DIP switch Bank Locations The table below provides a descri...

Page 4: ...to uplink port F1 and ports P3 and P4 are only Page 8 forwarded to uplink port F2 This prevents broadcast traffic from flooding other network ports Incoming traffic from F1 and F2 follows MAC address...

Page 5: ...ve link on F2 is detected 2 Installing the Module Wall Mounting The wall mounting height of the module should be less than or equal to 2 meters 6 6 feet from the floor Use the four mounting holes on t...

Page 6: ...power source must be connected to the terminal on the module and the negative lead of the power source to the terminal on the module as shown above Power Options WARNING Note the wire colors used in m...

Page 7: ...z Port is transmitting or receiving data Green Blinking at 1Hz Port in redundant secondary mode 10G Speed OFF Port not linked Amber Blinking at 1Hz Port not linked and receiving remote fault or FEFI G...

Page 8: ...C not available for models with AC DC power adapter Storage 40 to 80 C Humidity 5 to 95 non condensing Altitude 100m to 4 000m operational MTBF hours Module Only 272 000 AC DC Adapter 100 000 Warrant...