Operations

 

For Asbestos and mold abatement, the machine must be operated with a HEPA filter in place. Also, it is recommended to use the 
primary/secondary filer and replace it frequently to extend the life of the HEPA.

 

 

Speed Control

 

The OA2000C has two speed settings: Low and High.  These will operate the machine at 900CFM and 1600 CFM respectively.  
 
The OA2000V has a variable speed setting, which operates the machine between 400 and 1600 CFM.  The unit can also be fixed 
at a high speed using the HIGH/VARIABLE speed selector switch. 

Start the Machine

 

 
For the OA2000C, simply turn the switch to HIGH or LOW speed position. 
 
For the OA2000V, to start the machine in high speed, set the rocker switch HIGH/VARIABLE speed to the HIGH position. In this 
position the SPEED CONTROL is disabled. To start the machine in VARIABLE SPEED, set the rocker switch to the VARIABLE 
SPEED position and rotate the SPEED CONTROL knob clockwise to obtain the desired airflow.  
 
As the filters fill with dust, the efficiency of the filters is maintained, but the airflow will decrease, and the vacuum reading will 
increase. Change the primary/secondary filter frequently to protect the HEPA and to get more air flow. When amber indicator 
light comes on, the REPALCE FILTER indicating light will turn on and the HEPA filter will have to be replaced to increase the 
air flow.  Accessories such as an optional intake manifold can be used on the suction side of the unit providing 

12”

 connection 

for the flex duct. 

The discharge side of the unit has a 12” diameter ring for a flex duct.

 

Summary of Contents for OmniAire 2000C Series

Page 1: ...1 2000C 2000V Series HEPA Air Filtration Machine Operation and Maintenance Manual ...

Page 2: ...SERVER CES INSTRUCTIONS Cet équipement doit être utilisé que par un personnel formé Ne pas utiliser avec des matières combustibles ou explosives Ne pas exposer à l eau ou à la pluie Connectez uniquement à une prise mise à la terre avec un dispositif GFCI Coupez l alimentation électrique pour le nettoyage et l entretien Ne pas utiliser si le cordon ou la fiche est endommagé Contactez un centre de s...

Page 3: ...ent and hook a flexible duct to the outlet ring of the machine ducting the exhaust into the containment See Above OmniAire 2000 Specifications Airflow 900CFM Low 1900 CFM OA2000C 400 1900 CFM Variable Range OA2000V Power Requirements 115VAC 60 Hz 10 6 Amp or 230VAC 60Hz 6 0A Motor 1 25 HP with thermal overload 115VAC or 1 0 HP with thermal overload 230VAC Optional MERV 15 bag filter OdorGuard 600 ...

Page 4: ...set the rocker switch HIGH VARIABLE speed to the HIGH position In this position the SPEED CONTROL is disabled To start the machine in VARIABLE SPEED set the rocker switch to the VARIABLE SPEED position and rotate the SPEED CONTROL knob clockwise to obtain the desired airflow As the filters fill with dust the efficiency of the filters is maintained but the airflow will decrease and the vacuum readi...

Page 5: ...uides and re install the filter tabs and filter tab securing nuts The nuts should initially be tightened to where the stud is flush with the end of the nut This will compress the gasket on the filter approximately 1 2 of the thickness This allows for the filter to be reseated and tightened at a later time if necessary Bag Filter Replacement For the projects that do not require a HEPA filter the ec...

Page 6: ...ected to the capacitor is plugged in and not broken Re plug the unit into the power outlet keeping the switch in the OFF position Then push the blower wheel and as it is spinning turn the speed selector switch to HIGH If the machine keeps running the capacitor needs to be replaced The machine will run for a few minutes then turn off 1 The machine must have a HEPA filter installed to operate proper...

Page 7: ...FILTER 99 97 0 3μ pb frame OAH2418 Bag Filter Housing includes 1 Bag Filter HBF2000 Bag Filter MERV 15 OBF9 Vapor Trap V bank Filter OCVT18 OdorGuard 600 Carbon Filter OG2418D Intake Manifold Kit Manifold Clamp 3 Duct OAIM2000 12KIT ABS Plastic Intake Manifold 12 Dia OAIM2000 12 Quick Clamp 12 16 Dia QCW14 Flexible Duct 12 Dia x 25 L OAD12 Flexible Duct Wire Fiber Reinforced OAD12R Revision 2 0 Se...

Page 8: ...review the Equipment application and federal state and local regulations to be sure that the Equipment installation and use will comply with them Omni CleanAir offers extended warranty through the Gold Care Membership Program for as long as membership status is maintained For more information please visit https www omnicleanair com resources gold care membership To Submit a Warranty Claim or Recei...