OPS-UM-001-C User Manual 

OmniPreSense Corporation 

Default Settings 

The default settings of the sensor are set to provide solid performance over a wide range of applications.  
Upon power-up the default settings are used, and operation begins.  Future updates will allow the module 
to retain the settings of the sensor from the last operation.  The default settings are listed in Table 1.   

Table 1. Default Settings 

API Command 

API Command 

Default Value 

Output Units 

UM 

m/s 

Data Accuracy 

F2 

Sample Rate 

SX 

10,000 

Sample Buffer Size 

S> 

1024 

Reported Speed Filter 

R=

n

 

Off 

Reported Direction Filter 

R| 

Off 

Quash Noise 

QQ 

On 

JSON Output 

Oj 

Off 

LED Control 

OL 

On 

Magnitude Report 

Om 

Off 

Number Reports 

O

n

 

Raw Data Output 

Or 

Off 

Speed Report 

OS 

On 

Time Report 

Ot 

Off 

Module Power 

PA 

Active 

 

Operating Range 

The  maximum  speed  reported  is  determined  by  the  Sampling  Frequency.    For slow  moving  objects,  a 
sample rate of 5,000 (SV command) is perfectly fine.  The default setting of 10,000 (SX command) provides 
a detectable speed of up to 31.1 m/s (69.5 mph) while 20,000 (S2 command) provides up to 62.2 m/s 
(139.1 mph).  The accuracy of the reported speed increases  as the sample frequency goes down.  The 
range of values is summarized in Table 2. 

Table 2. Maximum Operating Speeds 

Sample 

Frequency 

API 

Command 

Maximum 

Speed (m/s) 

Maximum 

Speed (mph) 

Accuracy* 

(m/s) 

Accuracy* 

(mph) 

1,000 

SI 

3.1 

7.0 

0.006 

0.014 

5,000 

SV 

15.5 

34.8 

0.030 

0.068 

10,000 

SX 

31.1 

69.5 

0.061 

0.136 

20,000 

S2 

62.2 

139.1 

0.121 

0.272 

50,000 

SL 

155.4 

347.7 

0.304 

0.679 

100,000 

SC 

310.8 

695.4 

0.608 

1.358 

 

 

* 1024 buffer size, 512 buffer size accuracy will be twice these values

 

 

 

 

Summary of Contents for OPS242

Page 1: ...ions The OPS242 provides a complete radar module on a single board The coverage area or field of view FOV for the OPS242 is 76 in the azimuth horizontal and elevation vertical Install the OPS242 facin...

Page 2: ...configuration window such as in Figure 2 or Figure 3 will appear TeraTerm can detect the active COM port greyed out to right of Serial button if TCP IP is selected Select the Serial button and press...

Page 3: ...OPS UM 001 C User Manual OmniPreSense Corporation 3 Figure 4 Streaming Data with Tera Term Figure 5 Streaming Data with PuTTY...

Page 4: ...Output Or Off Speed Report OS On Time Report Ot Off Module Power PA Active Operating Range The maximum speed reported is determined by the Sampling Frequency For slow moving objects a sample rate of...

Page 5: ...ber returns sensor model number consisting of OmniPreSense ACPI vendor ID and part number Command Name R W Value P Sensor Part Number Read Product OMPS242A Firmware Version returns current firmware ve...

Page 6: ...rted The buffer size influences the report rate and accuracy A buffer size of 512 will have a report rate between 5 30Hz The accuracy becomes worse by a factor of two with a 512 buffer size versus 102...

Page 7: ...orts outbound direction R Clear Direction Control Write Reports both directions Frequency Control use this setting to set the desired transmit frequency Set n to a positive or negative number between...

Page 8: ...te Turn the LEDs on OL or off Ol Turning off the LED s can save approximately 10mA of current consumption On Number Reports Write Define how many reports to provide n is a number between 1 and 9 The n...

Page 9: ...powered down for further power savings PP Single Shot Mode Write Use this mode to capture and process a single buffer of data The module will stay in PP mode until either a PA or PI command is given...

Page 10: ...umbers are least sensitive Command Name R W Value QI Squelch Control 100 Write Highest sensitivity setting QV Squelch Control 500 Write QX Squelch Control 1 000 Write QL Squelch Control 5 000 Write QC...

Page 11: ...cian for help FCC 15C Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must...

Page 12: ...not approved any changes or modifications to this device by the user Any changes or modifications could void the user s authority to operate the equipment The final product containing the modular tran...

Page 13: ...M 001 C User Manual OmniPreSense Corporation 13 Revision History Version Date Description A July 9 2018 Initial release B August 10 2018 FCC language added C August 27 2018 Correction to frequency cha...

Reviews: