5

 

2.2 Schematic Diagram 

 

 

Note: 

The inverter topology consists of boost and inversion. PV input feeds into the 

public power grid via DC filtering, boosting, DC bus decoupling, inverter and AC filtering. 

 

It  adopts  DSP  and  MCU  dual-chip redundancy  technology  to realize  fault  detection 

and protection  of  the  inverter. The  interior  of  the  inverter  has  two  groups  of relays 

connected  between  the inverter  circuit  output  and power  grid  port, and 

the  groups  of 

relays have  self-test  function  that can ensure  reliable  disconnecting  of  the 
connection between the inverter circuit and the utility grid in the event of a failure. 
It realizes the remote monitoring of the PV power generation system via the communication 
methods of RS485, GPRS and Wi-Fi. 

2.3 Appearance of Inverter 

 

 

No.  Description 

Explanation 

 

LED Display Panel 

To display the inverter running state / communication 

status 

PV insulation
resistance
detection

LED

Bluetooth

RS485

RS485

WIFI/GPRS

MASTER MCU

SLAVE MCU

Leakage
current
deteciton

DC switch

MPPT circuit

Grid-connected
        relay

L1

L2

L3

N

PE

PV1+

PV1-

PV2+

PV2-

Summary of Contents for Omniksol-10KW-TL3-NS

Page 1: ...User Manual Grid Connected Inverter Omniksol 5KW 6KW TH TL3 NS 8KW 10KW 13KW 16KW TL3 NS...

Page 2: ...your purchase or use Unless otherwise specified in the contract no presentation is made or warranty either express or implied as to the contents of this document As standards specifications and desig...

Page 3: ...ion 10 4 1 Mounting Location 10 4 2 Mounting the Inverter 10 5 Electrical Connection 13 5 1 Safety Precautions 13 5 2 Cable Requirements 13 5 3 DC Connection 14 5 4 AC Connection 15 5 5 Second Protect...

Page 4: ...inor or moderate injury NOTICE NOTICE is used to address practices not related to physical injury but to property damage NOTE NOTE is additional information in the manual which is emphasis and supplem...

Page 5: ...tions and safety precautions in this document Operation in extreme environments which are not specified in this document Operation beyond specified ranges Unauthorized modifications to the product or...

Page 6: ...sensitive components may result in damage to the components Avoid unnecessary contacts with circuit boards Comply with electrostatic protection standards wear an antistatic wrist strap When installin...

Page 7: ...ted into DC via PV modules and then the DC is converted into sinusoidal AC which has the same frequency and phase as the utility grid and fed into the utility grid via inverters Components Description...

Page 8: ...and the groups of relays have self test function that can ensure reliable disconnecting of the connection between the inverter circuit and the utility grid in the event of a failure It realizes the re...

Page 9: ...on Interface of demand response modes for Australia grid dispatching AC Output Terminals To feed the inverter output energy into the grid Ammeter Communication and Digital Input Input interface for el...

Page 10: ...A 13kVA 16kVA Max Output Current 7 3A 8 7A 11 6A 14 5A 18 9A 23 2A Rated Grid Voltage 230 400V 3W N PE Grid Voltage Range 176 276V 304 480V Rated Grid Frequency 50 60Hz Gird Frequency Range 45 55 55 6...

Page 11: ...ge may still occur during transport Check that the delivery is complete check the packaging and the inverter for externally visible damage and inspect the package contents upon receipt Notify the carr...

Page 12: ...erter should be stacked it is recommended that the maximum number of layers can be accumulated no more than 5 layers The inverter must avoid the corrosive chemicals otherwise it may be corroded It nee...

Page 13: ...n a closed enclosure otherwise the inverter should be too hot to operate or even damaged The inverter should be installed in the reinforced concrete wall or metal wall that can bear the weight of the...

Page 14: ...splay at eye level and by keeping a distance of 100 cm from the front All cables are routed to the outside through the underside of the enclosure Therefore a minimum clearance of 50 cm must be observe...

Page 15: ...ll mounting bracket on both sides using the M5 screws provided Tighten the screws and make sure that they are securely in place 5 The Wall mounting bracket reserved a padlock hole to prevent the inver...

Page 16: ...ided otherwise the IP rating of the inverter may be reduced CAUTION All cables must be connected firmly and reliably properly insulated and avoid to be damaged easily CAUTION The inverter can only be...

Page 17: ...rcuit current for each PV string is no more than 12 A NOTE All models of inverters are featured with two MPPT inputs and two groups of input terminals and two groups of PV strings can be connected to...

Page 18: ...damage to the inverter 4 Disconnect the circuit breaker on the DC side and connect the PV input cable to the inverter separately 5 4 AC Connection WARNING Ensure that electrical connections are in com...

Page 19: ...he PE wire is properly grounded As shown in the figure below 3 Insert the shell into the AC terminal hear a sound of click then tighten the waterproof connector cap 4 Push the locker onto the socket h...

Page 20: ...nt on the enclosure There is a protective grounding hole at the bottom of the inverter The user must make the inverter grounded through the grounding hole and tighten it with M4 8 screws As shown in t...

Page 21: ...front end of the connection point between the inverter all loads and the grid that is close to the public power grid The direction of the current transformer CT is from the user side to the public po...

Page 22: ...ption 2 Live A No special requirements 5 Live B No special requirements 8 Live C No special requirements 10 Neutral No special requirements 1 CT Live A White wire 3 CT Live A Black wire 4 CT Live B Wh...

Page 23: ...serted into the COM2 connector the RJ45 plug for DRM communication is inserted into the COM3 connector only for Australian configuration The enlarged image of the meter communication interface and DRM...

Page 24: ...cted to the COM2 and COM3 interfaces Please install the waterproof terminal to ensure the waterproof performance of the inverter when external network cables are connected to the COM2 and COM3 interfa...

Page 25: ...ts and flashes and the inverter starts detecting 5 When the illumination conditions meet the working requirements of the inverter the inverter will automatically start running and deliver power to the...

Page 26: ...ame time it indicates that a program upgrade is in progress Do not perform any operation before the program upgrade is completed 7 4 Auto test function For Italy There is only the Italian grid connect...

Page 27: ...24 So far the auto test is completed...

Page 28: ...on App The user can view the running status of the inverter configure the operational parameters and upgrade the software via the professional App Professional App is recommended for professionals ope...

Page 29: ...og in in the App home page and enter your email and password 8 1 3 Create Plant 1 Method 1 Click on Add in the App home page and click the Plant icon from the pop up menu then scan the serial number o...

Page 30: ...n Enter the interface of plant information after successfully scanning the serial number or clicking on No Device Confirm your plant location GPS function will automatically locate the plant site If y...

Page 31: ...28 electricity prices and subsidies 3 Enter the plant name It is suggested to create a plant name like location name capacity then click on Done 4 Then the plant you added is shown on the homepage...

Page 32: ...tion to enable users to obtain the running status information of the inverter in time 8 2 1 Software Installation Search Solarman in Apple Store to download the App for iPhones Search Solarman in Goog...

Page 33: ...2 Edit Plant Information Confirm your plant location GPS function will automatically locate the plant site If you want to modify the location click the map icon and then manually enter the plant addre...

Page 34: ...31 3 Enter the plant name It is suggested to create a plant name like location name capacity then click on Done 4 Then the plant you added is listed on the homepage...

Page 35: ...d AC terminals Contact the local operation and maintenance personnel for any help PV Reversely Connected Positive and negative polarity of DC input PV 1 or PV 2 are reversely connected Contact the loc...

Reviews: