background image

User Manual V1.1 

                                                                                                                                                                                

 

 

 

 

User Manual       

-Installation 
-Operation

 

Omniksol-1k-TL-M 
Omniksol-1.5k-TL-M 

Omnik New Energy Co.,ltd 

Summary of Contents for Omniksol-1.5k-TL-M

Page 1: ...User Manual V1 1 User Manual Installation Operation Omniksol 1k TL M Omniksol 1 5k TL M Omnik New Energy Co ltd...

Page 2: ...2...

Page 3: ...Packing checklist 14 4 1 Assembly parts 14 4 2 Product Appearance 15 4 3 Product Identification 16 4 4 Further Information 16 5 Installation 17 5 1 Safety 17 5 2 Mounting Instructions 18 5 3 Safety Cl...

Page 4: ...4 7 3 Set Language 36 7 4 Instructions of Safety Standard selection when power up 37 7 5 State Information 38 8 Recycling and Disposal 39 9 Troubleshooting 40 10 Abbreviation 41 11 Contact 42...

Page 5: ...eep this user manual all time available in case of emergency 1 2 Symbols Used CAUTION CAUTION indicates a hazardous condition which if not avoided can result in minor or moderate injury WARNING WARNIN...

Page 6: ...re only for qualified personnel who are intended to install or uninstall the Omnik Grid Tie Solar Inverter NOTICE Hereby qualified personnel means he she has the valid license from the local authority...

Page 7: ...ions including modification of product functionality of any form will affect the validation of warranty service Omnik may deny the obligation of warranty service accordingly DANGER DANGER due to elect...

Page 8: ...h electricity generators and public grid Danger of hot surface The components inside the inverter will release a log of heat during operation DO NOT touch aluminum housing during operating CAUTION The...

Page 9: ...man Grid Regulations Certified Safety The inverter complies with the requirements of the Equipment and Product Safety Act in Europe Standards Association of Australian The inverter complies with the r...

Page 10: ...10 3 Product Information 3 1 Overview Industrial Layout Excellent Heat Elimination...

Page 11: ...nables more PV panels connected Wide MPP voltage range ensure high yield under various weather conditions High MPP tracking accuracy ensure the minimum power loses during converting Complete set of pr...

Page 12: ...V Nominal Grid Frequency 50Hz 60Hz 50Hz 60Hz Max AC Current 5 0A 6 25A Grid Voltage Range 185 276V 185 276V Grid Frequency Range 45 55Hz 55 65Hz 45 55Hz 55 65Hz Power Factor 0 99 0 99 Total Harmonic D...

Page 13: ...P 65 According to IEC 60529 IP 65 According to IEC 60529 Cooling Concept Natural convection Natural convection Mounting Information Wall bracket Wall bracket General Data Operating Temperature Range 2...

Page 14: ...mpleteness for any visible external damage on the inverter or any accessories Contact your dealer if anything is damaged or missing A B C D E F G H Object Quantity Description A 1 Omnik inverter B 1 p...

Page 15: ...15 4 2 Product Appearance Front Object Description A LED light Green RUN B LED light Red FAULT C Function key for displays and choice of language Bottom A B C C A B...

Page 16: ...type of the inverter as well as inverter specifications are specified on the side name plate The name plate is on the middle part of the right side of the inverter housing And the following figure is...

Page 17: ...r Do not expose to rain and snow cover to enhance inverter life time The installation site MUST have good ventilation condition DANGER DANGER to life due to potential fire or electricity shock DO NOT...

Page 18: ...re the wall you selected is strong enough to handle the screws and bear the weight of the inverter Ensure the device is properly fixed to the wall It is not recommended that the inverter is exposed to...

Page 19: ...e following minimum clearances to walls other devices or objects to guarantee sufficient heat dissipation and enough space for pulling the electronic solar switch handle Direction Minimum clearance Ab...

Page 20: ...all mounting bracket in the carton box 2 First according to the marks drill 2 holes in the wall Then place two expansion tubes in the holes using a rubber hammer Next make 2 screws through the mountin...

Page 21: ...21 3 Align both sides of the radiator on the hooks of the back panel move the inverter from left to right horizontally until the hooks completely into the slot of the radiator...

Page 22: ...the left side of the inverter as the picture showed below Recommended padlock dimension A Shackle Diameter 3 5 mm B Vertical Clearance 8 15 mm C Horizontal Clearance 12 20 mm Stainless solid hanger a...

Page 23: ...ctricity shock NEVER connect or disconnect the connectors under load NOTICE Electrical connections shall be carried out in accordance with the applicable regulations such as conductor sections fuses P...

Page 24: ...h of AC cable terminal length x about 14mm 0 55 of the inner wrapper then dress the conductor terminals with ferrules or tin soldering 2 Check that all parts of AC connector are present Then slide hex...

Page 25: ...and PE conductor terminal to the appointed holes use a cross screwdriver to tighten it with tightening torque 1Nm 4 Insert the connector to clamp ring with two click sound and then tighten the hex nu...

Page 26: ...the locker according to the direction instructed by the marks on the locker 6 If you need to separate the connectors please use a screwdriver to press the lock tongue rotate the locker according to t...

Page 27: ...compliance with the technical data can be guaranteed For protection against electric shock PV connectors must be isolated from the power supply while being assembled or disassembled The end product mu...

Page 28: ...he roof surface See the MC catalogue 2 Solar line for technical data and assembled parts PV Female cable coupler PV Male cable coupler Optional PV KBT4 PV KST4 PV SSH4 Touch protection mated unmated I...

Page 29: ...6 Open end spanner A F 15 mm ill 7 Torque screwdriver A F 12 mm ill 8 Test plug PV PST Order No 32 6028 Cable preparation ill 9 Important Cables with class 2 5 or 6 construction can be connected It is...

Page 30: ...ngages Pull lightly on the lead to check that the metal part has engaged Assembly control ill 13 Insert the test pin with the corresponding side into the socket or plug to the end position If the cont...

Page 31: ...ntil they engage Check correct engagement by pulling on the coupling Unplugging ill 16 Compress the two snap in springs X by hand or with the PV MS tool and separate the coupling Plugging and unpluggi...

Page 32: ...communications that is up to 50 Omnik inverters can be connected one by one through these 2 plugs and the cables the upper computer can communicate with these inverters via a single signal cable at t...

Page 33: ...check and set the data In addition the user can press the function key to illuminate the LCD screen NOTICE Omnik inverter is not an aligned measuring instrument for current voltage or power consumpti...

Page 34: ...Pac xxxx W The top line Line 1 shows current state information by default and by pressing function key it will display different operating information as the following flow chart and table NOTICE Mak...

Page 35: ...State information Pac xxxx W Iac Pac xxxx W E total Pac xxxx W Vpv Pac xxxx W Ipv Pac xxxx W E today Pac xxxx W Vac Pac xxxx W Model Pac xxxx W Ver Pac xxxx W Set Language Pac xxxx W Frequency Pac xxx...

Page 36: ...present grid current Frequency The grid frequency Model The type of the inverter Ver The Firmware version Set Language Several languages are provided for users reference to 7 3 for further information...

Page 37: ...KWh 2 Operation steps are as following 2 1 Power on the inverter with only DC side connected while disconnecting cables of AC side 2 2 Press the Function button until the LCD displays inverter s model...

Page 38: ...y Loss No Utility Island PV Over Voltage Input voltage too high Over Temperature Temperature abnormal Isolation Fault Isolation failure Relay Check Fail Output relay failure DC INJ High Output DC inje...

Page 39: ...the end of its life must be collected separately and returned to an approved recycling facility Any device that you no longer required must be returned to your dealer or you must find an approved coll...

Page 40: ...s 1 Grid is not connected 2 Check grid connection cables 3 Check grid usability 4 If grid is ok and the problem persists maybe the fuse in the inverter is open please call service Over Temperature 1 T...

Page 41: ...aximum Power Point Impp Amperage at Maximum Power Point AC Alternating Current Form of electricity supplied by Utility Company DC Direct Current Form of electricity generated by PV modules VDE 0126 1...

Page 42: ...86 512 6295 6676 Fax 86 512 6295 6682 Email info omnik solar com www omnik solar com Omnik German Service Center An der Pikardie 6 01277 Dresden Deutschland Tel 49 179 9762 654 Email service de omnik...

Reviews: