background image

displayed value.

The additional parameter can be displayed by default upon switching the
Omnicomm LLD indicator on. For this purpose, in Omnicomm Configurator, in the
«Settings» section, in «The display mode at startup» field, select the «Additional
parameter» option.

To display the vehicle speed, the values read from the universal input and the volume
of fuel dispensed, it is necessary to edit the appropriate settings of the Omnicomm
Terminal.

Technical Specification

Specification

Value

Supply voltage, V

from + 8 to + 45

Network interface

RS-485

Data exchange rate via EIA-485 interface by default, bit/sec

19 200

Calibration table, rows

56

Number of the connectable Omnicomm LLS sensors

2

Ambient operating temperature, ˚С

from - 40 to + 70

Overall dimensions, mm

137х61х23

11

Technical Specification

Summary of Contents for LLD

Page 1: ...Omnicomm LLD fuel volume indicator User Manual Omnicomm Configurator 6 26 04 2019...

Page 2: ...Contents General information 3 Setting up 4 Installation and Connection 6 Purpose of the Indicator Lights 9 Displaying Fuel Volume 9 Displaying Additional Parameter 9 Technical Specification 11...

Page 3: ...e of fuel filled in the tank during refueling vehicle speed with Omnicomm terminals only volume of fuel dispensed by fuel tanker truck with Omnicomm Profi terminals only value from Omnicomm terminal u...

Page 4: ...Setting up Connect the Omnicomm LLD indicator to the PC using UNU or Omnicomm UNU USB according to the scheme or 4 Settingup...

Page 5: ...Omnicomm LLS fuel level sensors 4 Set the brightness level for the indicator at startup The following options are available maximum minimum off The minimum brightness level is set by default 5 If nec...

Page 6: ...fixation holes according to the installation dimensions on the back side of a place of installation install a washer and a nut which are both included in the delivery set While installing the Omnicom...

Page 7: ...Omnicomm LLS sensor terminal or on board network of the vehicle is generated according to the scheme If it is necessary to connect two Omnicomm LLS sensors it is recommended to use two KTZ splitters...

Page 8: ...485 B White blue RS 232 Tx Pink RS 232 Rx Gray V power Brown Ground White Purposes and colors of the wires in the cable of the Omnicomm LLD indicator when connecting without a connector Name of signal...

Page 9: ...or the 2 LED emits light Displaying Additional Parameter Displaying an additional parameter and returning to the default information is enabled by long pushing i e longer than 3 s the button If necess...

Page 10: ...ng pushing the button 3 Displaying the value read from the Terminal s universal input This parameter allows you to monitor the Terminal s universal input status or value depending on the type of the c...

Page 11: ...values read from the universal input and the volume of fuel dispensed it is necessary to edit the appropriate settings of the Omnicomm Terminal Technical Specification Specification Value Supply volt...

Page 12: ...info omnicomm world com www omnicomm world com...

Reviews: