background image

1. Gate Installation

T e mperature m easurement m odule

White Light Lamp

C a mera

D i splay s creen

C r edit c ard a rea

g r ip n ut 

s t and t ype s upport 

Summary of Contents for F800W

Page 1: ...F800W Indoor Safety Access Thermometer Installation manual Shenzhen Ophelia Technology Co Ltd ...

Page 2: ...ents of the document but there are still some technical inaccuracies discrepancies with the function and operation of the product or printing errors in case of any doubt or dispute please subject to our final explanation products and documents will be updated in real time without prior notice The contents of this document only provide reference guidance for users please refer to the actual content...

Page 3: ...ent and safe temperature measuring terminal for visual face recognition The product can be applied to the traffic scene of intelligent community access control channel face attendance hotel office building school shopping mall and so on which is helpful to realize intelligent safety control ...

Page 4: ...inocular In vivo Detection Support for Human Motion Face Tracking Exposure in Strong Inverse Light Environment 5W Face recognition time in vivo detection is less than 0 2 seconds under face database The CPU uses Hayes 3516 DV300u operation Linux system the system is stable Abundant hardware interface Wigan RJ45 8 inch IPS screen resolution 800 1280 IC card unlock face recognition unlock QR code un...

Page 5: ...IC MIC Speakers 8Ω1W Network 10 100 1000 Mbps Ethernet support POE power supply Power supply Adaptor DC12V 2A Vegan Support Wegan send and Wegan receive support Wegan 26 34 format Relay interface COM NO NC GPIO interface Support three way extension extended interface use configurable door magnetic input door button signal input smoke alarm input doorbell signal output Alarm Protection Micro touch ...

Page 6: ...1 Gate Installation Temperature measurement module White Light Lamp Camera Display screen Credit card area grip nut stand type support ...

Page 7: ...te position as shown 2 through all wire locking nuts 3 Connect according to electrical wiring mode Top view Side view Gate hole size Front panel of gate C o n tact Point of N e t work Open Door S i g nal Module R e l ay module P o w er port n etwork port P o r t connection I D c ard reader ...

Page 8: ...le 2 Wiring photos 3 Interface definition Serialnumber Name Number Remarks 1 Network 1 RJ45 2 Power supply 1 DC12V IN 3 USB 1 USB2 0 4 Switch output 1 KZ_OUT NO KZ_OUT COM 5 Wegan Protocol Input Interface 1 VCC 12V GND D0 D1 6 The output interface of Wegan Protocol 1 vcc12V GND D0 D1 ...

Page 9: ...2 wall mount Temperature measurement module White Light Lamp Camera Display screen Credit card area fix screw Wall mount support fix screw ...

Page 10: ...h the positioning film to the installation equipment position and open the hole according to the positioning film position 2 Electrical wiring mode good wiring 3 Remove the positioning film wire through the back hole with M3 20mm screws fixed the machine ...

Page 11: ...2 1 Installation Steps and Schematic Schemes ...

Page 12: ...e 2 Wiring photos 3 Interface definition Serial number Name Number Remarks 1 Network 1 RJ45 2 Power supply 1 DC12V IN 3 USB 1 USB2 0 4 Switch output 1 KZ_OUT NO KZ_OUT COM 5 Wegan Protocol Input Interface 1 VCC 12V GND D0 D1 6 The output interface of Wegan Protocol 1 vcc12V GND D0 D1 ...

Page 13: ...ed according to the actual situation 4 Better to keep the ambient light intensity above 100 lux Note If the current ambient temperature is outside the 10 50 C range the temperature is too low or too high High condition can carry on the temperature compensation through the background has measured the temperature gun actually to measure the temperature to be accurate compensation is carried out for ...

Page 14: ...ble to perform an exit or termination operation power it up reset and restart by cutting off and switching it on again 3 Check equipment input voltage recommended DC 12V 2A 5 2 No face recognition or low recognition rate 1 In the process of recognition whether there is part occlusion or whether the face is in the recognition area 2 The light is darker and the brightness of the lamp is improved 3 S...

Page 15: ...5 FAQ treatment 5 3 Gate not open 1 Check whether the network connection is normal re plug 2 Check whether the Wigan signal line is connected properly and re plug ...

Page 16: ...ign matter fall into the inside of this equipment to prevent short circuit or cause equipment damage If the equipment fails or foreign objects enter the internal immediately disconnect the power supply and consult the manufacturer or seller Do not put the equipment on a dangerous platform to prevent the equipment from falling smashing wounding or damage to the equipment itself The power plug shoul...

Page 17: ...in or contact the maintenance centre when a Damaged or worn out power cord or plug b The abnormal placement or use of the equipment causes water to enter the equipment c Damage to casing or panel caused by equipment drop d Equipment can not be used properly in accordance with this manual e There are other obvious anomalies in the equipment such as lighting camera without imaging no gate control si...