REMOVABLE HOSES

Nomex Covered

Hose 

Control Unit 

Connector

Cup Connector

With Sensors

Hose Switch

Connector

Cup Side

Hose Switch

Connector

Pump Side

The removable hoses connect the cup to the hose switch and/or 

control unit. These hoses are reusable and should be inspected and 

tested before each flight - replace after 25 flights. 

Hose 

Lengths: 

18”/24"

Hose 

Lengths: 

12"/18”/24"

Summary of Contents for Skydrate

Page 1: ...USER MAINTENANCE GUIDE...

Page 2: ...2...

Page 3: ...rol Unit 9 Charger Batteries 10 Hose Switch 11 Removable Hoses 12 Collection Bag 13 Male Cup 14 Undergarment 15 Male System Overview 16 Charging the System 17 Donning the System 18 Prepping the System...

Page 4: ...oid your warranty 8 Refer all servicing to Omni Service Technicians under the following conditions When the power supply cord or plug is damaged If the product does not operate If the product has been...

Page 5: ...5 SYSTEM COMPONENTS Male Cup Collection Bag Control Unit Male Hose Cup Side Male Hose Control Unit Side Hose Switch Battery Charger Battery...

Page 6: ...at harness at all times QUICKSTART How Does The Skydrate Work The Skydrate system is simple to use Worn discretely beneath the flight suit the collection cup hose connector contains sensors that will...

Page 7: ...t If not make sure that the cup hose is accessible via the flight suit s zipper BEFORE TAKE OFF 1 Ensure that the control unit is fully charged all green lights 2 Ensure that the system is fully conne...

Page 8: ...harger 2 Battery Packs 1 Wall Power Adaptor 1 User Manual KIT CONTENTS Gen 3 Control Unit with QR Code for easy access to Omni s Training and Supply App Charger with 2 Battery Packs Batteries are ship...

Page 9: ...9 CONTROL UNIT Bag Release Battery Status Indicator Green LEDs GREEN Push Button Manual Activation Sensor Pins Hose Ports Battery Release Latch...

Page 10: ...the battery is taken out of sleep mode charged for the first time the batteries must be fully recharged every 6 months The battery charger is only for use with the Skydrate rechargeable battery packs...

Page 11: ...l Button Manually activates the liquid pump while held Removable Hose Control Unit Side Note Black Connector is Color Coded to the Hose Switch Removable Hose Cup Side Note Tan Connector is Color Coded...

Page 12: ...rs Hose Switch Connector Cup Side Hose Switch Connector Pump Side The removable hoses connect the cup to the hose switch and or control unit These hoses are reusable and should be inspected and tested...

Page 13: ...ling Standard Reusable Bag Filled with 1200mL Filled with 2200 mL The Collection Bag is manufactured from durable medical grade urethane The standard bags have a capacity of 1200mL While not recommend...

Page 14: ...al use in all aircraft including aircraft with the 5 point harness The cup is reusable at the user s discretion for up to 20 flights or 30 days with proper cleaning Soft Foam Ring Medical Grade Latex...

Page 15: ...undergarments are used to hold the Cup in place They should be sized for a snug fit Features No melt no drip construction Lightweight and Breathable Machine washable MALE GARMENT MG XX MF WAIST 32 34...

Page 16: ...itch Control Unit and Collection Bag They are connected together as pictured below These are the only components required on a mission Additional batteries and bags may be taken as needed Green Status...

Page 17: ...k must be charged prior to the first use It make take up to 2 5 hours A solid GREEN light indicates that the battery is charged A flashing YELLOW light indicates that the battery is charging A flashin...

Page 18: ...t and insert the male anatomy through the foam ring Secure the pocket Alignment Flaps If necessary the alignment flaps can be cut off and discarded to provide a more comfortable fit Depending on which...

Page 19: ...king sure that the foam ring is aligned with the hole If the garment is currently donned insert the penis through the hole in the fabric and through the foam ring of the cup Open the cup pocket flaps...

Page 20: ...operly hold the Male Cup in place Ensure that the hose can be retrieved through the bottom zipper after donning flight gear Once seated in aircraft adjust the cup for comfort and ensure that the tip o...

Page 21: ...onnection is made Roll the Control Unit up in the Collection Bag and store in an available pocket that is accessible during flight Press the GREEN push button for 1 second and release to display the b...

Page 22: ...rol Unit When the user urinates the sensors in the Hose Connector automatically detect urine and activate the Control Unit pump transferring the urine from the cup and into the Collection Bag To avoid...

Page 23: ...Unit from the Bag press the release button and slide the unit away from the clip Drain reusable collection bag Either dispose of Collection Bag and Male Cup or clean for reuse See Care and Maintenance...

Page 24: ...O NOT submerge past the release button 7 Press and hold the M push button for 5 seconds then remove the Control Unit from the water and hold the button for an additional 5 seconds to dry out the Contr...

Page 25: ...onnector to the Control Unit 2 The Control Unit should beep twice 3 If the Control Unit does not emit an audible beep press and hold the M button to activate the pump If the user needs to manually ope...

Page 26: ...75 W X 1 H Rechargeable Battery Specifications Chemistry Lithium Polymer Voltage 7 6V Capacity 680 mAh Charge Cycles 500 Storage See page 24 Weight 1 oz Dimensions 2 32 L X 1 2 W X 0 6 H Battery Charg...

Page 27: ...tain the system in accordance with Omni instructions or as a result of unauthorized alteration or repairs Damage occurring during transit is not covered by this warranty No other warranty expressed or...

Page 28: ...To re order supplies please contact Omni Defense Technologies 808 Hercules Drive Colchester VT 05446 Phone 1 802 497 2253 Fax 1 802 497 3601 OMNI DEFENSE COM Rev M220331 1...

Reviews: