In  addition  to  the  CFM/CMM  reading,  this  menu  also  shows  you  the  current  number  of  Air 
Changes per Hour (ACH), based on your fan settings and the room size you have entered. For 
instance, if you had a 2500 cubic foot room and your fan was set at 500cfm, your ACH would be 
12 (60 minutes divided by 2500/500). The example above shows an ACH of ???; this would be 
the reading if you skipped the Guided Setup or entered “I Don’t Know” in the Enter Room Size 
menu. 

6

Enter Room ID allows you to assign a 3 digit 
alpha-numeric code to the space the unit is located in. 
This is helpful if you plan to move it frequently. Use the 
UP/DOWN arrows to change; OK to select. 

The unit will then go into operational mode. The display 
will show Cubic Feet per Minute (CFM) or Cubic Meters 
per Minute (CMM). This can be adjusted using the 
UP/DOWN arrows. 

Press OK to return to the Main Menu. Select Activate 
Safety Lock
, then press OK again to lock the current 
settings. This will prevent tampering. Press OK twice 
again to unlock and adjust settings. 

In addition to the above, from the Main Menu there is 
also an option for Passcode Setup. This feature is 
reserved for administrators or authorized users to 
provide additional security. Contact your administrator 
for more information. 

Normal Operations 

Now that Guided Setup has been completed, your unit will return to those settings each time it 
is turned on. To change these settings, press OK and toggle to Enter Setup Mode. Make desired 
changes  and  select  Go  Back  to  return  to  normal  operating  status.  The  machine  must  be 
operated with a HEPA and pleated PreFilter in place. 

Summary of Contents for CleanAir OCA 500 Professional Series

Page 1: ...Operation and Maintenance Manual OCA 500 1200 Professional Series Air Puri cation Machine omnicleanair com 425 512 0379 info omnicleanair com 4640 Campus Place Ste 100 Mukilteo WA 98275...

Page 2: ...ning Location ID 6 Lock Unlock Settings 6 Settings Review 6 Normal Operations Machine Information Check 7 HEPA Filtration 7 UVGI Lights 7 PreFilter 7 Machine Status Check 7 Maintenance Troubleshooting...

Page 3: ...rug or carpet High intensity Ultraviolet light inside Avoid eye and skin exposure omnicleanair com 425 512 0379 info omnicleanair com 4640 Campus Place Ste 100 Mukilteo WA 98275 Product Description T...

Page 4: ...s 37kg 100lbs 46kg HEPA Dimension 12x12x12 in 16x16x12 in PreFilter Dimension 12x12x12 in 16x16x12 in Warranty 2 years 2 years Accessories Filters Gold Care Membership GCM 1 GCM 1 UVC Bulbs Pack of 2...

Page 5: ...urs consult the Troubleshooting section of this manual You will then access the Enter Guided Setup screen Press OK to enter room size and room ID information or select Do this later to bypass setup No...

Page 6: ...ect The unit will then go into operational mode The display will show Cubic Feet per Minute CFM or Cubic Meters per Minute CMM This can be adjusted using the UP DOWN arrows Press OK to return to the M...

Page 7: ...imum Ef ciency Reporting Value MERV 11 and is designed to remove dust pollen mold spores and other small particles from the air before it passes through the HEPA lter This will signi cantly extend the...

Page 8: ...t the user and describe the issue The table below lists the errors in order of their priority If more than one error occurs simultaneously the display will show the higher priority error rst then move...

Page 9: ...ide the drawer forward to access the bulbs The lights are each held in with 2 clips gently pull the light out of the two U clips then disconnect the 4 pin connector Replace the 4 bulbs and return the...

Page 10: ...pport to troubleshoot further 2 The machine just hums when turned on a Unplug the unit b Contact Omni CleanAir Technical Support for further information 3 The machine vibrates excessively when running...

Page 11: ...ed by this warranty policy Damage caused by an act of nature such as ood re wind earthquake or lightning Damage caused during shipping or an impact event with other objects Damage caused by improper c...

Page 12: ...fective and under warranty Omni CleanAir will repair or replace at our discretion any faulty parts or equipment A Return Merchandise Authorization RMA will be issued for the defective product Upon rec...

Reviews: