background image

In order to configure the IP Address the user should first connect a PC/
Laptop to the gateway via a Ethernet patch cable and power on the 
gateway.

The default IP address on the Multitech gateway is 192.168.2.1, to connect to 
the gateway the user must first configure their computers Ip address to be 
within the same subnet range for example 192.168.2.10.

Once this has been configured the user can login onto the gateway 
via their browser by typing in the IP address of the gateway as follows,  
https://192.168.2.1 (MultiTech IP67 setup POE setup: ‘’Out’’ on POE injector 
connects to IP67, ‘’In’’ connects to PC/ Switch/Router Default IP: 192.168.2.1 
Or configure PC to obtain IP4 address automatically as IP67 serves as DHCP 
server by default Connect IP67 base station directly to PC and access 
settings from PC’s web browser by 192.168.2.1 Initial setup Follow 1st time 
auto setup from web portal Specify IP address according to local network 
Specify Gateway as IP of local gateway Preferred DNS as IP of Local gateway 
Secondary DNS as 8.8.8.8)

Please follow instructions as shown in below screen shots,

V21220SLP

32

4.2.1  Configuring IP Address

Summary of Contents for Sense IoT

Page 1: ...KIT USER GUIDE LOCATE POSITION...

Page 2: ...ted network server and then to a subsequent application server The Sense Locate Position is perfect when high volumes of devices with low communication needs are required It is very power efficient to...

Page 3: ...ice Gateway beacon LoRa Network Join Request Sense Locate Position Data Payload Device s configurable settings Configuring Sense Locate Position with Sense Config PC App Sleep Tag Configuring Sense Lo...

Page 4: ...updated position This device will not provide position while moving if this is required please contact Omni ID to discuss this requirement Sense Locate Position is designed for tracking and monitorin...

Page 5: ...beacon rate is the frequency at which the tag beacons its sensor data under normal conditions not moving and within temperature threshold The tag default beacon rate can be set as a value of 1 255 Ho...

Page 6: ...not set The device will only send 1 Motion detected triggered beacon while moving Motion Stopped The Device transmits a single beacon when it senses that movement has stopped it sends its last know l...

Page 7: ...S Firmware basic algorithm Following flow diagram simplifies GNSS algorithm based on Tag s motion state sensed by Accelerometer Sensor Figure 1 MAB basic operation showing GNSS activation process V212...

Page 8: ...1 5 Operation Flow Chart Figure 2 Above flow chart documents the device s operation V21220SLP 7...

Page 9: ...n is a Class A LoRaWAN device which uses OTTA Over the Air Authentication procedure to join a LoRaWAN network During the join procedure the device transmits a join request and waits for response from...

Page 10: ...isation service Once Network Server accepts join request the device then generates following session keys based on App Key NwSKey Network Session Key To be shared with Network server AppSKey Applicati...

Page 11: ...at the communication between the device and the network has failed If device fails to receive acknowledgement for three consecutive beacons at either ABR DBR or MAB it will reinitiate the join request...

Page 12: ...construction is detailed in this section Following example demonstrates how the raw payload is parsed into the various data device variables Device to gateway Beacon Pay Load D4EB0D033A69F4FF2D1D41 V2...

Page 13: ...Data Rate at ADR the network server dictates the Data Rate and automatically adjust bit rate to optimize battery life and communication distance o 0 SF 12 125kH 250 bits s o 1 SF 11 125kH 440 bits s...

Page 14: ...SI values and try to get GPS Fix DoP Dilution of Precision Values can be set between 1 0 to 10 with increment of 0 1 o Default setting of 5 0 for fast lock achieving an accuracy of 5 10m and DOP 3 0 f...

Page 15: ...ith Sense Config PC App Supplied Hardware ST M24LR NFC Board USB device for PC Supplied Software Sense Config PC APP Figure 4 Configuration of Sense Locate Position using NFC board NFC Programming Boa...

Page 16: ...Read Settings to read preconfigured settings Choose new settings from right hand column and press Write Settings V21220SLP 15 Configured Settings Choose settings to configure Place the Sense Locate Po...

Page 17: ...o sleep when Tag is not in use to conserve battery Select Awake in Tag status field and hit Write Data at the bottom of App page to awaken the Tag before deployment Alternatively the device can be awa...

Page 18: ...e LoRa by following link http 35 160 220 150 wdc default aspx The app provides the user with 4 menu options Fast Lock o Loads optimal default values for GNSS Fast Lock o DOP 5 0 GNSS Min0min GNSS Max...

Page 19: ...e setting can be set via the settings Default Values tab in the application Please enter values as below EUI 16 Hex Value 5370656374726531 Key 32 HEX Value 44434C20476174657761792030303031 Toggle Save...

Page 20: ...uick lock that is accurate between 5 10m use the Fast Lock option This is ideal for large assets that are easily recognisable like plant and farm equipment Note GNSS DOP Value is automatically configu...

Page 21: ...3 2 3 High Accuracy For a lock with an accuracy of between 1 5m use this option the lock time will be slower than fast lock Note GNSS DOP Value is automatically configured to 3 0 V21220SLP 20...

Page 22: ...3 2 4 Advanced For a lock with an accuracy of between 1 5m use this option the lock time will be slower than fast lock V21220SLP 21...

Page 23: ...al elements and forwarded in JSON format to any end application over HTTP Example Pay Load 80590d030f7df3ffa11d41 JSON sent from gateway to end application over HTTP Mac_Address 37 37 33 38 5c 37 6f 0...

Page 24: ...4 1 OmniSphere User Guide LOGIN SCREEN Enter Username and password provided URL and login details will be provided by Omni ID V21220SLP 23...

Page 25: ...s indicator icons and device types are displayed at Home Page Device Types Devices are grouped under each device type and all devices under that device type can be seen by selecting device type from l...

Page 26: ...V21220SLP 25 TO SEE DATA FROM A SPECIFIC TAG Select Device from List Click on View Click on View Item Readings to see data from multiple beacons as shown on next page Shows most recent Changes Beacon...

Page 27: ...V21220SLP 26 Data can be filtered Historical Data of Device can be downloaded as CSV file...

Page 28: ...V21220SLP 27 MAP VIEWS Select a map to view devices location Bread Crumb view of device Interval time can be selected to view history of devices for set time interval...

Page 29: ...V21220SLP 28 Selecting Max no of values 1 shows Devices Last most recent location Device History can be filtered by number of values beacons...

Page 30: ...with Demo kit are preconfigured on OmniSphere and will work out of box more devices can be added to OmniSphere if you wish by following below instructions Select to create new device Select to choose...

Page 31: ...n all events and reports Choose Customer Organization Add Status Indicators Only if already not been selected under Item Types Click on Device Enter same Device Name as General Tab Enter same ID as Ge...

Page 32: ...nd configuration if required The gateway is supplied in the demo kit configured in DHCP Client mode and needs to be connected to Network work switch via an Ethernet patch cable to provide access to th...

Page 33: ...of the gateway as follows https 192 168 2 1 MultiTech IP67 setup POE setup Out on POE injector connects to IP67 In connects to PC Switch Router Default IP 192 168 2 1 Or configure PC to obtain IP4 ad...

Page 34: ...On connection to the gateway the following screen will be displayed The username is admin The password is Password123 V21220SLP 33...

Page 35: ...ing up the gateway The first step is to configure the IP settings of the gateway to those of the host network click the setup tab Select Network Interfaces Click the pencil icon under Options V21220SL...

Page 36: ...Fill in the IP settings for the local network below Click Finish Save and restart V21220SLP 35...

Page 37: ...be opened in the firewall of the local router Port 443 Port 1882 These should be set to forward to the address that you have configured for the gateway The following shows the settings for a gateway...

Page 38: ...on The Sense Locate Position IoT device is hugely powerful and flexible thanks to the combination of GPS and LoRa technology As a result the device will deliver high levels of outdoor accuracy and per...

Page 39: ...n minutes HighTemperatureThreshold GNSS Maximum LockTime LowTemperatureThreshold GNSS Minimum LockTime AccelerometerThreshold GNSS DoPThreshold Meeting Your Requirements Our Sense range of IoT devices...

Page 40: ...MHz US 868MHz EU 915MHz US 868MHz EU 915MHz US 866 868 EU 902 928 US Battery Type Sealed Prismatic battery non replaceable Sealed Prismatic battery non replaceable Sealed Prismatic battery non replace...

Page 41: ...ptional Film Adhesive Mechanical std Film Adhesive optional Film adhesive included for placement only in applications exceeding 85 C 2 Operating Temperature 20 C to 60 C 20 C to 60 C 20 C to 60 C 20 C...

Page 42: ......

Reviews: