![Omker OMK-K373 Instruction Manual Download Page 2](http://html.mh-extra.com/html/omker/omk-k373/omk-k373_instruction-manual_738867002.webp)
2
Press OPEN key once more=door close
Press OPEN key again=door open
Cycle in this way. When choosing single key control, one remote control can control at
most 4 gates.
For example, use OPEN to control gate 1, use CLOSE to control gate 2, use STOP to
control gate 3,use LOCK to control gate 4.
5. Manual single key function:
you can choose normal open switch without electric voltage
like doorbell to connect with GND and ONE. Single key manual cycle operation:
OPEN-STOP-CLOSE-STOP.
6. Motor force adjustment(soft star force adjustment):
(You should turn on RED DIP
switch 4 to ON).
Motor with soft star low speed function,star slowly and stop slowly,low speed force can
be adjusted by TORQUE potentiometer.Clockwise to increase the strength,(as the strength
increase,low speed function will not obviously ).Anti clockwise to decrease the strength(as
the strength decrease,low speed function will become obviously).If the gate is very big or
heavy,it is not recommend to use this function.
7. Resistance rebound function:
(you should turn on RED DIP switch 5 to ON)
During closing of the motor,door will stop when meeting obstructions and rebound, to
ensure safe of person and vehicle.Resistance strength can be adjusted by FORCE
potentiometer, clockwise to increase the strength,anti clockwise to decrease the
strength.Strength adjust potentiometer (TORQUE) can adjust strength of the motor make
rebound more obviously.You can also turn on RED DIP switch 5 to OFF, turn off resistance
function.(Not recommend)
8. Anti-clamping function:
During closing of the door, when there are obstructions blocks
the infrared rays, the door will automatically stop,and moves reversely in case of clamp
people or objects.It’s strongly recommended to add infrared anti-clamping function,
especially when performing auto close function to avoid unnecessary losses.
9
.
Adjust motor running direction without changing lines:
If the door open and close in
opposite direction after installation, just turn the motor direction switch to the opposite
direction.
10. Adjust travel direction without changing lines:
If the door travel in opposite direction
after installation, just turn the travel direction switch to opposite direction. (If LED, L1-L2
light up at the same time or open to the limit can stop but can’t close, close to the limit can
stop but can’t open,that is because magnet installation position is not correct,just make high
position magnet higher,and low position magnet Lower.
11
.
Travel connection:
Travel can choose mechanical or reed switch(noted:normal open
connection,short of NC is normal close travel).Travel common line in the middle, left is for
open limit,right is for close limit.
You can also switch to single travel mode by P2 PIN. If one of the travel limits is
broken,you can switch to single travel mode,adjust position of t magnet or spring plate to the
same height,it will not affect normal use.
12
.
LED fault display:
It is easy to carry out maintenance and use through LED screen.