![Omicron Ti Series User Manual Download Page 9](http://html1.mh-extra.com/html/omicron/ti-series/ti-series_user-manual_3986635009.webp)
Maintenance Instructions
C.
B.
A.
Depending on your frequency of usage, the electrical contact points should be cleaned at least
once every 3 - 7 days. The Omicron Ti Series Vaporizer uses relatively low voltage to operate and even
a small amount of residue on the contact points and/or threads can reduce the voltage flow,
impeding the performance of your Omicron. Any residue bridging the gap between the
threads and center post on your Omicron Ti Series, could cause a very dangerous electrical
short resulting in physical injury to yourself and damage to the battery and/or
your Omicron
Keep It Clean !
After every thing is completely dry, lightly touch the contact areas and threads with your
fingers. If you feel any tacky areas, please repeat the cleaning procedure steps A - C again
until all the contact areas and threads are tack free.
Once cleaned, use the dry end of the cotton swab to help the drying process by gently
running it over the areas just cleaned. Be careful that no cotton gets left behind on any
surfaces or threads.
Using the ISO dampened end of the cotton swab, gently scrub and clean any residue from all
the contact surfaces and threads on all your cartridges and Omicron Ti Series Vaporizer
The contact surfaces are all the areas that make contact with each other when a cartridge is
screwed into the Omicron.
To clean the electrical contact points and threads, take a cotton swab (Q-Tip) and dip one end
into some Isopropyl Alcohol (ISO). The higher percentage of purity, the better, try to use as
close to 99% ISO as you can.
By following these simple maintenance steps, you will keep your Omicron Ti Series Vaporizer performing
at peak performance.
Your Omicron Ti Series Vaporizer has been designed to be easy to care for and maintain.
DO:
Use ISO to clean the contact areas and threads on all your cartridges
DO:
Use ISO to clean the contact areas and threads on your Omicron Ti Series Vaporizer
DO:
Keep your Lithium Ion 14500 battery charged and in good physical condition
DO:
Submerse your Titanium cartridge in 99% ISO to clean (Do Not submerge plastic mouthpiece)
DON’T:
Try to use a cartridge still damp with ISO
DON’T:
Leave behind any lint or cotton on the cleaned surfaces or threads
DON’T:
Screw a cartridge on to the Omicron Ti Series Vaporizer with out cleaning both first
DON’T:
Allow a fully charged battery to sit in the charger for extended periods of time
AVOID:
Using metallic applicators on the KISS cartridges, you will damage the heating coil
Page 8
Omicron Ti User Guide
Omicron Ti User Guide
UP TECH
O
M
IC
R
O
N
Copyright Utopia Planitia Technologies 2014 Distributed by
©
www.w9tech.com