OMG AZIMUTH User Manual Download Page 1

AZIMUTH

AZIMUTH

MANUALE D’USO E MANUTENZIONE

USER MANUAL

Summary of Contents for AZIMUTH

Page 1: ...AZIMUTH AZIMUTH MANUALE D USO E MANUTENZIONE USER MANUAL...

Page 2: ......

Page 3: ...WWW REBREATHER AZIMUTH COM WWW REBREATHER COM AZIMUTH SEMI CLOSED REBREATHER MANUALE D USO E MANUTENZIONE USER MANUAL...

Page 4: ......

Page 5: ......

Page 6: ...utilizzata V erifica del funzionamento dei corrugati e del rubinetto a quattro vie Verifica finale del funzionamento dell autorespiratore Impiego dell autorespiratore Manutenzione ordinaria 1 2 3 5 7...

Page 7: ...tipo che come preserie dimostrandosi all altezza delle migliori aspettative in ogni condizione d uso La mancanza di complicati quanto poco affidabili meccanismi e l estrema facilit di manutenzione ne...

Page 8: ...a chiunque non sia in possesso della certificazione all uso di questo autorespiratore Questo manuale pu non contenere tutte le informazioni necessarie per un uso in sicurezza dell autorespiratore Azim...

Page 9: ...one di pericolo potenziale che se non evitata potrebbe procurare la morte o lesioni gravi PRUDENZA PRUDENZA Indica una situazione di pericolo potenziale che se non evitata potrebbe infliggere lesioni...

Page 10: ...petto ad un autorespiratore tradizionale a circuito aperto Infatti rigenerando la miscela respiratoria aumenta notevolmente l autonomia permettendo al subacqueo di rimanere immerso pi a lungo ad una p...

Page 11: ...rso il gruppo dosatore il subacqueo pu azionare un by pass per l immissione di miscela dalla bombola ed inoltre pu inserire in qualsiasi momento nel circuito anche la seconda bombola Ai riduttori di p...

Page 12: ...te da evitare in quanto espone il subacqueo a gravissimi rischi come iperossia o ipossia che possono portare a gravi incidenti anche mortali per il subacqueo ed i suoi accompagnatori Siate assolutamen...

Page 13: ...to sui quadranti dei manometri collegati Tale valore deve essere compatibile con la pressione di esercizio stampigliata sul corpo bombola in caso contrario procedere al caricamento come di seguito des...

Page 14: ...flusso continuo d dopo alcuni secondi necessari per lo stabilizzarsi della portata controllare che sul flussometro la portata sia esattamente sull indice segnato la corrispondenza tra indice tipo di...

Page 15: ...previsti non sperimentate tarature differenti un diverso valore di pressione pu causare un funzionamento anomalo dei sacchi polmone con rischio di gravi incidenti anche mortali per il subacqueo RIEMPI...

Page 16: ...e a posizionare l autorespiratore in posizione verticale utilizzando come appoggio l apposito supporto a compasso ed aprire completamente il coperchio posteriore Fig 21 b controllare la corrispondenza...

Page 17: ...ne con l autorespiratore non in perfetta efficienza pu essere estremamente rischioso e causare gravi incidenti anche mortali per il subacqueo In caso di perdita dai sacchi polmone sostituire o riparar...

Page 18: ...che la camma del gruppo dosatore sia in posizione di chiusura Fig 33 10 aprire lentamente e completamente il rubinetto della valvola di intercettazione della bombola superiore 11 aprire lentamente e...

Page 19: ...in qualsiasi momento anche senza attendere la completa scarica della bombola principale La mancata osservanza di queste raccomandaz ioni pu essere estremamente pericolosa e pu essere causa di gravi in...

Page 20: ...iugarlo e liberare i fori da eventuali frammenti di granuli di calce sodata Fig 43 5 smontare i tubi corrugati e il rubinetto a quattro vie Fig 44 lavarli accuratamente con abbondante acqua dolce disi...

Page 21: ...Fig A...

Page 22: ...and illustrated CONTENTS Introduction Safety information Functional description Preparation for use Tanks pressure checking and refilling Breathing mix oxygen percentage checking Breathing mix active...

Page 23: ...and pre production phases and has consistently fulfilled the highest expectations under all conditions The absence of complex and potentially unreliable mechanisms together with its extremely simple m...

Page 24: ...rebreather be used by anyone who does not hold a certificate and is not properly trained This manual may not contain all the necessary informations for a safe use of the Azimuth rebreather but if cou...

Page 25: ...lly follow the procedures indicated Indicates an imminent hazard which if not avoided may result in serious injury or death Indicates a potential hazard which if not avoided may result in serious inju...

Page 26: ...e diver s air time allowing him or her to stay longer at any given depth and letting out fewer bubbles Because the chemical process which regenerates the breathing mix requires all parts to be in perf...

Page 27: ...en consumed by the diver s breathing metabolism By means of the active flow regulator group the diver can operate a bypass valve to manually inject the breathing mix from the tank and can even add the...

Page 28: ...nuous flow rates and mixtures as this exposes the diver to serious risks such as hyperoxia and hypoxia which may lead to serious or fatal injuries for the diver and his parteners Be absolutely certain...

Page 29: ...shut off valves and read the value on the pressure gauge of each tank This reading must comply with the working pressure stamped on the tank body if this is not the case proceed to fill the tank as de...

Page 30: ...e a few seconds to stabilize then check the rate measured on the flowmeter to be settled exactly just on the index mark setting Matching of index mark gas breathing mix kind and flow rate is shown in...

Page 31: ...ver attempt to use different calibrations as a different pressure value may lead to malfunction of the counterlungs putting the diver at risk of serious or even fatal accidents FILLING THE SCRUBBER UN...

Page 32: ...the operation of the corrugated hoses and the four way valve proceed as follows a place the rebreather in the vertical position resting it on its special standt then fully open the rear cover Fig 21 b...

Page 33: ...a proper working shape may be extremely dangerous and put your own life at risk of serious or even fatal accidents In case of replace or repair replace the connector O Ring seal in the tank s shut of...

Page 34: ...water 9 make sure the continuous flow regulator group cam is in the closed position Fig 33 10 slowly turn the upper tank s shut off valve to the fully open position 11 slowly turn the lower tank s shu...

Page 35: ...y tank to be empty Failure to observe these precautions can be extremely dangerous and may cause serious or even fatal accidents to the diver Should the diver for any reason abandon the mouthpiece whi...

Page 36: ...ments and granules from the holes Fig 43 5 disassemble the corrugated hoses and the four way valve Fig 44 wash them thoroughly in plenty of fresh water disinfect with an O M G antibacterial solution o...

Page 37: ...Fig A...

Page 38: ...06 06 04 04 05 05 09 09 07 07 08 08 03 03 01 01 02 02...

Page 39: ...16 16 17 17 15 15 13 13 14 14 12 12 10 10 11 11 18 18...

Page 40: ...24 24 22 22 23 23 27 27 25 25 26 26 21 21 19 19 20 20...

Page 41: ...33 33 31 31 32 32 36 36 34 34 35 35 30 30 28 28 29 29...

Page 42: ...42 42 40 40 41 41 45 45 43 43 44 44 39 39 37 37 38 38...

Page 43: ...48 48 46 46 47 47...

Page 44: ...NOTES NOTES...

Page 45: ...AZIMUTH AZIMUTH...

Page 46: ......

Page 47: ...OMG ITALIA Via Vincinella 14 19037 S Stefano Magra SP www omg italy it www rebreather azimuth com Mod MTUM_AZ_01_IE...

Reviews: