OMG AccuTrac EZ Owner'S Manual Download Page 11

AccuTrac / RhinoTrac Owner’s Manual

  Page 11

  TROUBLESHOOTING PROBLEMS

PROBLEM: DRIVE SHAFT IS BROKEN

POTENTIAL CAUSE

REMEDY

Drive shaft is broken.

Replace drive shaft.

PROBLEM: PLATE NOT SEATING TIGHTLY                                               

Improper depth adjustment.

Tighten the depth adjustment.

Screw gun is in reverse.

Make sure switch is in forward position.

Incorrect drive bit, or worn/ broken bit.

Check to make sure correct drive bit is installed. Replace 
worn or broken drive bits.

Screw gun not properly installed or fully tightened.

Check screw gun; tighten if necessary.

Excessive build-up of material on wheels/casting.

Remove built-up material.

Obstruction in tubes and/or casting.

Check upper and lower tubes and casting, remove any 
obstructions.

PROBLEM: TOOL WILL NOT RETRACT INTO FULL UPWARD POSITION    

Operator is not allowing tool to fully retract.

Downward pressure on tool must be fully released after 
the plate has been fastened. Tool should “spring” up into 
correct position. If necessary, tug upwards.

Plate Shuttler or tubes are dirty.

Clean and oil Plate Shuttler and tubes.

Nose-piece is bent or damaged.

Call 1.413.789.0252 for service. Do not attempt to remove 
nose-piece.

Fastener wedged between feed tube and nose-
piece.

Remove feed tube and clear fastener jam.

PROBLEM: TOOL IS SLUGGISH               

Plate Shuttler needs lubricating.

Lubricate the Plate Shuttler.

Dirty upper and lower tubes, Plate Shuttler, guides 
and drive bar slots.

Remove debris. Clean all parts with a degreaser and 
lubricate.

Upper and/or lower tubes are bent or damaged.

Replace worn or damaged tubes as needed.

Nose-piece retaining screw is worn or the nose-
piece is damaged.

Call 1. 413.789.0252 for service. Do not attempt to remove 
nose-piece.

PROBLEM: FASTENER EXTENDS OUT OF THE DRIVE SHAFT AND   

             

 

JAMS THE TOOL               

Short fasteners rotate easier than long fasteners 
through the tube to the nose-piece and sometimes 
extend through the opening.

Tilt the AccuTrac EZ / RhinoTrac EZ tool back when  
feeding the fasteners down the feeder tube.

If you have followed the recommendations above, but the problems persist, please call the OMG Roofing 
Products Technical Services Department at 1.413.789.0252.

Summary of Contents for AccuTrac EZ

Page 1: ...ES ROAD AGAWAM MA 01001 USA 800 633 3800 413 789 0252 RHINOBOND COM New EZ Indicator Technology shows users when plate and fastener are ready for installation IMPORTANT Save this manual and read it in...

Page 2: ...E NOTE This manual deals only with the use and operation of the AccuTrac EZ and RhinoTrac EZ tool For specific information about the use operation and limitations of the screw gun component of the too...

Page 3: ...tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Arcing could occur which could ignite the dust or fumes c Keep children and bystanders away while operating p...

Page 4: ...re idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untra...

Page 5: ...OMG Roofing Products are approved for use with these tools Do not use these tools for any other purpose AccuTrac EZ and RhinoTrac EZ tools can injure people and damage property Please be sure that yo...

Page 6: ...indica tors alert users to avoid loading two screws at the same time Redesigned plate shuttle links are easier to compress for all day comfort Accomplish more projects with interchangeable boots for i...

Page 7: ...uth funnel 3 Lock the screw gun trigger in the ON position Using the lock will keep the screw gun running cooler Push the tool downward to drive the screw through the insulation until it contacts the...

Page 8: ...red and black Star Knobs See page 12 par EZ1283214 at the top of the shaft on the screw gun motor mount 2 Pull screw gun straight up You might need to pull a little bit harder to get the screw gun out...

Page 9: ...es it may be necessary to release the flags in the end of the nose piece to fully access the jam The flags can be released by pinching the top of both flags together 3 For clearing plate jams first ma...

Page 10: ...e 242 and reinstall screws Plate retaining spring is not completely seated Turn the handle clockwise and gently pull upward Plate rod is not completely seated Turn the handle clockwise and gently pull...

Page 11: ...g upwards Plate Shuttler or tubes are dirty Clean and oil Plate Shuttler and tubes Nose piece is bent or damaged Call 1 413 789 0252 for service Do not attempt to remove nose piece Fastener wedged bet...

Page 12: ...AccuTrac RhinoTrac Owner s Manual Page 15 NOTES...

Page 13: ...OMG Roofing Products 153 Bowles Road Agawam MA 01001 USA 800 633 3800 413 789 0252 www rhinobond com...