7.)
Changing the necessary number of coins:
Use the
UP
or
DOWN
button to navigate to
Pn02
and press the
Confirm
button. The display will now show the number of coins required to
open the shutter. Change the number with the
UP
and
DOWN
buttons. The mechanism
requires at least 1 coin. The default value is set to 1 coin. This is the recommended setting.
Press
CONFIRM
to lock this number and press
BACK
to return to the settings menu.
8.)
Changing the time the shutter stays open:
Use the
UP
and
DOWN
buttons to navigate to
Pn01
and press the
CONFIRM
button. The display will now show the seconds the shutter will
be open after inserting the right amount of valid coins. The default value is 30 seconds.
Change the value with the
UP
and
DOWN
buttons and then press the
CONFIRM
button.
Press the
BACK
button to return to the settings menu.
(This setting displays the amount of seconds
per inserted coin!
If
Pn02
is set (for example) to
3
coins, and
PN01
is set to
30
seconds, than the shutter opens after inserting
3
valid coins
and stays open for
90
seconds.)
9.)
After changing Pn01 and Pn02 to the desired values, hold down the
BACK
button for a few
seconds. The display will change to
END.
After a few seconds, the display will show
Pn01
or
Pn02
again.
Do NOT press any buttons now!
Wait for another 15 seconds without pressing
any button. The Display now changes to
END
and stays there permanently.
10.)
Testing:
Insert a valid coin that matches the attached reference coin. The Display will count
the inserted coins. If the number reaches the value set as
PN02
(usually 1 coin), the shutter
will open.
The Display now shows the remaining seconds until the shutter closes as a countdown.
Once the shutter closes, the display will turn off to save energy. Inserting another coin won’t
activate the display again. The mechanism will work as specified without wasting energy for
the display.
To change the settings, disconnect and reconnect the power supply again.