13
SPECIFIC CLEANING PROCEDURES
Aluminum Housings
·
In the ultrasonic bath, preheat 1 part OmegaSupreme with 10 parts clean water to a
temperature of 125
˚F.
·
Wipe off the readily accessible, exterior excess from the parts to be cleaned.
·
Arrange the parts so that no trapped air exits in the interior when lowered.
·
Set the time for 2-5 minutes and start the cleaning cycle.
·
If additional cleaning is needed, at the end of the first cycle, rotate the parts 180
˚ in
the basket so that the portion that was facing the bottom of the tank is now facing
the top and vice versa.
·
Clean the parts for another 2-5 minutes.
·
When completed, rinse the parts with clean, hot water that is 125
˚F.
·
Blow off excess moisture using compressed air or a hot air blower.
Cylinder Heads
·
In the ultrasonic bath, preheat 1 part OmegaSupreme with 10 parts clean water to a
temperature of 165
˚F.
·
Using a basket, lower the part into the bath and clean for 20 minutes.
·
At the end of the first cycle, rotate the part 180
˚ and clean for an additional 25
minutes.
·
Once the part is clean, remove from the bath and rinse using clean, hot water.
·
Blow off excess water using compressed air.
·
Part will flash dry.
·
For more aggressive cleaning, use 1 part OmegaSupreme with 10 parts water.
NOTE: OmegaSupreme is a stronger detergent and can accelerate starbursts in the
aluminum surface.