WMS-T-AL Dual Set Point Temperature Alarm

Introduction

The WMS-T-AL is a microprocessor-based dual set point Temperature Alarm packaged in a 
NEMA 4X box with a transparent cover. It has been designed with two independently 
controlled relays. The relays are used to control power to the users temperature sensitive 
device(s) or to operate operator selected secondary alarms. The control module has a liquid 
crystal digital display and push buttons for viewing and selection of the operating mode and 
the alarm threshold values. The user can control three parameters for each alarm channel: 
Threshold delay before the relay triggers after threshold temperature is crossed, and delay time 
before the relay turns off after the temperature re-crosses the threshold . Each relay can be used 
in either the normally open or the normally closed mode. A piezoelectric buzzer in the control 
module can be activated to turn on when ever the alarm state is active.

General Description

The WMS-T-AL consists of two components a temperature sensor to measure temperature and 
a control module.

TEMPERATURE SENSOR

The temperature sensing probe is based on a precision thermistor and is designed to measure 
over a wide range of temperatures. The thermistor has a resistance value of 10,000 ohms at 25°C 
and has a highly reproducible response curve. The sensor accuracy is ±1°F (±0.55°C). Resolution 
is to 0.1°F (0.05°C). The measurement range is from -40°F (-40°C) to 160°F (60°C). The Alarm 
range is from -40°F (-3°C) to 160°F (+3°C). The temperature sensor is supplied with a 40 ft. 
Cable.

CONTROL MODULE

The function of the Control Module is to activate its control relays when ever user selected 
temperature vales are reached and sustained for user determined periods of time. The Control 
Module is microprocessor based and is controlled via push buttons and a two-row-liquid-
crystal-display. There are Option Switches on the printed circuit board for selection of 
temperature units (°F or °C) , for enabling the audible alarm, and a potentiometer for 
controlling the LCD contrast.

User Interface

There are two modes of operation for the model WMS-T-AL Temperature Alarm. RUNNING 
and PAUSED. The RUNNING mode is the normal operating mode when the unit is initially 
powered up. The PAUSED mode is any state other than the normal OPERATING mode. 
Pressing any button during the RUNNING mode will place the unit in the PAUSED mode.

1

Summary of Contents for WMS-T-AL

Page 1: ...omega com e mail info omega com For latest product manuals omegamanual info WMS T AL Dual Set Point Temperature Alarm MADE IN Shop online at User sGuide...

Page 2: ...n Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de United Kingdom One Omega Drive River Bend Technology Centre ISO 9002 Certified Northbank Ir...

Page 3: ...SOR The temperature sensing probe is based on a precision thermistor and is designed to measure over a wide range of temperatures The thermistor has a resistance value of 10 000 ohms at 25 C and has a...

Page 4: ...ns the unit to the RUNNING mode regardless of where the user may be in the menu structure The UP and DOWN Buttons The UP and DOWN buttons control either of two things 1 Scrolling through menu items wh...

Page 5: ...Temperature Sensor Placement The validity of temperature signals can be compromised by the choice of the location of the anemometer with respect to the surrounding terrain Placement of the temperature...

Page 6: ...Menu button The top line of the display will change from Temp XX X F to Temp Alarms F Press the Menu button again and the cursor moves over the Alarm 1 temperature value Press the Up or Dn button to...

Page 7: ...Range ON or Off 0 99 seconds Controls Four push buttons select 1 Run or Pause mode 2 Menu Select 3 Increment 4 Decrement Option slide switch Switches are read only during power up Switch 1 ON TEMPERAT...

Page 8: ...NOTES...

Page 9: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 10: ...ty Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...

Reviews: