background image

© Copyright 2006 OMEGA ENGINEERING, Inc. All rights reserved. This document may not be copied, photocopied, 
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the 
prior written consent of OMEGA ENGINEERING, INC

6

SEPDH series

1. Remove the two screws securing the metal plate opposite the temperature 
sensor.

2. Remove the metal plate to expose the low and high limit set-point controls.

3. Adjust the high and low temperature set-points to an appropriate level for the 
environment. The low temperature set-point is the process control. The high limit 
set point is connected to the high temperature limit indicator light.

NOTE: These heaters have a built-in, high limit thermostat that will prevent it from 
overheating. 
T-3 rated heaters: 292°F [145°C] high limit thermostat
T-4A rated heaters: 158°F [70°C] high limit thermostat

SHDH-C and SSDH-C series

2. For 120VAC model, plug standard 3-prong plug to appropriate electrical power 
supply. For 240VAC model, terminate power cord to appropriate electrical power 
supply. The power cable consists of three color-coded conductors, black, white, 
and green. The black wire should be connected to Line 1.  The white wire should 
be connected to Line 2.  The green wire should be connected to earth ground.  
The power connections must be adequately rated to electrially support the 
voltage and amperage of the heater. The identifi cation label located on the power 
cord displays voltage and amperage requirements. Follow all local electrical 
codes for proper electrical connections. 

Do not adjust the low set-point higher than the high limit 
thermostat.

Do not adjust the low set-point higher than the high temperature 
set-point connected to the indicator light.

4. Replace the metal plate and secure with two screws.

1. The drum heater is designed to work at a specifi c voltage. Refer to the lead 
wire label or stamp located on the heater for rated voltage and wattage.

Failure to operate the drum heater at its rated voltage could 
cause damage to the heater, surface being heated, or contents 
of drum.

All electrical connections must be made by qualifi ed personnel 
and in accordance with all local codes and regulations.

Properly sized circuit breakers must be used.

The end-user is responsible for providing suitable electrical 
protection device.  It is highly recommended that a ground fault 
circuit breaker be used.

CONNECTING HEATER TO AC POWER

ADJUSTMENT OF TEMPERATURE SET-POINT

© Copyright 2006 OMEGA ENGINEERING, Inc. All rights reserved. This document may not be copied, photocopied, 
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the 
prior written consent of OMEGA ENGINEERING, INC

IMPORTANT SAFETY INSTRUCTIONS

3

A person who has not read and 
understood all installation instructions 
is not qualifi ed to install this product.



Never handle the heater while it is 
in operation; always disconnect the 
heater from the power source and 
allow to cool prior to handling.



Inspect heater before use.  



Never operate heater without a 
temperature control device.



Do not wrap the heater over itself



If spillage of foreign matter onto 
heater occurs, disconnect from 
power source and clean after 
heater is allowed to cool.



Never operate a heater without an 
appropriate heat sink (device being 
heated is considered a heat sink).



Do not operate heater above rated 
temperature value.



Fasten heater to device using 
approved methods only.



Do not repair damaged or faulty 
heaters.



Do not crush or apply severe 
physical stress on heater or cord 
assembly.



Disconnect heater when not in use.



Use specifi ed sized heater with 
samed sized drum. Do not use for 
other applications.



SEPDH series: Never allow the full 
weight of the thermal bulb controller 
to hang from the heater.



SEPDH series: the metal enclosure 
must not support more than 10lbs 
(4.5kg).

Failure to observe these warnings may 
result in personal injury or damage to the 
heater.

Approvals valid only when

 installed in 

accordance with all applicable 
instructions, codes, and regulations.

Agency Approvals

SHDH and SSDH series

End User Must Comply to the Following:



Only qualifi ed personnel are allowed to connect 
electrical wiring.



Disconnect all supply power at the source before 
making any power connections.



All electrical wiring must follow local electrical 
codes and highly recommend following NEC 
Article 427.



Final installation / wiring is to be inspected by the 
authority who has jurisdication in the area that 
the heater is installed.



The end-user is responsible for providing a 
suitable disconnecting device.



The end-user is responsible for providing 
suitable electrical protection device. It is highly 
recommended that a ground fault circuit breaker 
is used.



SEPDH series: A NRTL (National Recognized 
Testing Laboratory) listed temperature controller 
must be used to control the surface temperature 
of the blankets.  The controller must be approved 
for the area where it is located.



SEPDH series: Heaters provide surface heating, 
consult proper authorities for information for 
safe heating of materials/ contents of any vessel 
heated by SEPDH heaters.

Failure to observe these warnings may result in 
personal injury or damage to the heater.



Do not immerse heater in liquid.



Keep volatile or combustible material away from 
heater when in use.



Use heater only in approved locations.



Keep sharp metal objects away from heater.



All SEPDH heaters have T ratings described 
in Article 501 of the NEC code. The heaters 
should not be used in an area with a lower T 
rating than the heater.  The T rating is stated in 
marking on the heater.

Failure to observe these warnings may result in 
electric shock, risk of fi re, and personal injury.

73/23/EC (Low Voltage Directive)

FM

APPROVED

Hazardous Locations
Class I, Division 2, Groups A*, B, 
C, & D
Class II, Division 2, Groups F & G

SEPDH series

* without included controller only

Reviews: