Transducer Output Table:
Transmitter Output in Milliamps
Temp
(°C)
Model
TM1M12
Model
TM2M12
Temp
(°C)
Model
TM1M12
Model
TM2M12
Temp
(°C)
Model
TM1M12
Model
TM2M12
-40
4.00
6
12.27
7.46
52
14.09
-39
4.18
7
12.45
7.60
53
14.23
-38
4.36
8
12.63
7.75
54
14.38
-37
4.54
9
12.81
7.89
55
14.52
-36
4.72
10
12.99
8.04
56
14.67
-35
4.90
11
13.17
8.18
57
14.81
-34
5.08
12
13.35
8.32
58
14.95
-33
5.26
13
13.53
8.47
59
15.10
-32
5.44
14
13.71
8.61
60
15.24
-31
5.62
15
13.89
8.76
61
15.39
-30
5.8
16
14.07
8.90
62
15.53
-29
5.98
17
14.25
9.05
63
15.68
-28
6.16
18
14.43
9.19
64
15.82
-27
6.34
19
14.61
9.33
65
15.96
-26
6.52
20
14.79
9.48
66
16.11
-25
6.70
21
14.97
9.62
67
16.25
-24
6.88
22
15.15
9.77
68
16.40
-23
7.06
23
15.33
9.91
69
16.54
-22
7.24
24
15.51
10.05
70
16.68
-21
7.42
25
15.69
10.20
71
16.83
-20
7.60
26
15.87
10.34
72
16.97
-19
7.78
27
16.04
10.49
73
17.12
-18
7.96
4.00
28
16.22
10.63
74
17.26
-17
8.13
4.14
29
16.40
10.77
75
17.41
-16
8.31
4.29
30
16.58
10.92
76
17.55
-15
8.49
4.43
31
16.76
11.06
77
17.69
-14
8.67
4.58
32
16.94
11.21
78
17.84
-13
8.85
4.72
33
17.12
11.35
79
17.98
-12
9.03
4.86
34
17.30
11.50
80
18.13
-11
9.21
5.01
35
17.48
11.64
81
18.27
-10
9.39
5.15
36
17.66
11.78
82
18.41
-9
9.57
5.30
37
17.84
11.93
83
18.56
-8
9.75
5.44
38
18.02
12.07
84
18.70
-7
9.93
5.59
39
18.20
12.22
85
18.85
-6
10.11
5.73
40
18.38
12.36
86
18.99
-5
10.29
5.87
41
18.56
12.50
87
19.14
-4
10.47
6.02
42
18.74
12.65
88
19.28
-3
10.65
6.16
43
18.92
12.79
89
19.42
-2
10.83
6.31
44
19.10
12.94
90
19.57
-1
11.01
6.45
45
19.28
13.08
91
19.71
0
11.19
6.59
46
19.46
13.23
92
19.86
1
11.37
6.74
47
19.64
13.37
93
20.00
2
11.55
6.88
48
19.82
13.51
3
11.73
7.03
49
20.00
13.66
4
11.91
7.17
50
13.80
5
12.09
7.32
51
13.95
regarding wiring, calibration and troubleshooting
of the transmitter.
Note: The plastic shell of the transmitter is
removed during assembly of the PRS-TMM12
transducer due to space limitations. The sides and
back of the transmitter are insulated with
polyimide adhesive tape to isolate it from the
sensor housing. If the transmitter is removed from
the housing during calibration or servicing, check
to insure that the transmitter continues to be
isolated from the housing during re-assembly.
Re-Assembly (See figure on page 1):
Re-assemble the housing as follows:
1. When re-assembling the cap to the housing,
position lead wires to insure that they will not
be pinched during replacement of the cap.
2. Check that the o-ring is in place as shown above.
3. Position the cap on the end of the housing,
gently turn the cap clockwise until the threads
engage (do not force).
4. Turn the cap until it is fully seated in the
housing. The cap should turn freely until the
o-ring seal reaches the top of the housing. A
1/2" wrench may be needed to complete the
operation due to the resistance of the o-ring seal.
2