6.Remove
Fireproof electric box
Twist off the screws on fireproof electric box and then
remove the fireproof electric box.
Fireproof
electric box
7. Remove chassis sub-assy
Isolation sheet
and Isolation sheet
Remove the 3 screws fixing the isolationsheet
and then remove the Isolation sheet.
8. Remove 4-way valve assy and electronic expansion
valve
Discharge the refrigerant completely;unsolder
the pipelines connecting the compressor and
the condenser assy,and then remove the 4-way
valve assy and electronic expansion valve.
4-way valve assy
Electronic Expansion Valve
Steps