SAFETY RULES AND RECOMMENDATIONS FOR USE 

PROHIBITION 

Never switch on or off the circuit breaker or touch the buttons with wet hands. You may be shocked.

Do not insert your fingers or other objects into the air inlet / outlet grilles.

Do not insert any object or liquid (metal object, piece of paper, water, etc.) into the air inlet or outlet grille. The internal
blower (which can rotate at high speed) or the high voltage sections can cause injury or electric shock.

Do not clean the inside of the air conditioner yourself. Ask your dealer to clean the air conditioner internally. Improper
cleaning  can  result  in  breakage  of  resin  parts  or  deterioration  of  the  insulation  of  electrical  components,  which  may
result in water leakage, electric shock or fire.

Do not place heavy objects on the power cable, expose it to heat, or pull on it. Otherwise, there is a risk of electric shock
or fire.

Do  not  use  any  other  refrigerant  than  the  one  specified.  Otherwise,  abnormally  high  pressure  may  occur  in  the
refrigeration cycle, which can lead to product malfunction, explosion or even personal injury.

Do not bend, pull or crush the power cord as this may damage it.

Electric shocks and fires are usually caused by a damaged power cord. Only a qualified technician should replace a
damaged power cord.

Do not use an extension cord or multiple plug.

Do not touch the device if parts of your body are humid or wet.

Do not obstruct the air inlet or outlet of the wall unit or outdoor unit.

Clogging of these openings could cause a decrease in the efficiency of the air conditioner with the possibility of
subsequent failures.

Do not alter the characteristics of the device in any way.

Do not install the unit in an environment that may contain gasoline, oil, or sulfur or near a heat source.

Do not climb, do not place heavy or hot objects on the top of the unit.

Do not leave doors or windows open for extended periods while the air conditioner is running.

Do not direct the air flow onto plants or animals.

Prolonged direct exposure to the cold air conditioner could have a negative effect on plants or animals.

Do not put the air conditioner in contact with water. Electrical insulation could be damaged and cause a risk of electric
shock.

Do not climb or place objects on the outdoor unit.

Never insert a stick or similar object into the outdoor unit. You could be seriously injured.

WARNING 

The manufacturer declines all responsibility for damage caused by non-observance of the safety instructions in this user
manual.

Be careful not to install, repair, open or remove the cabinet. You may be exposed to dangerous voltages. Ask the dealer
or a professional to do so.

Always use the air conditioner with the air filter in place. Use without the air filter could cause excessive accumulation
of dust and other residues on the internal components resulting in subsequent failures.

The fins should be down in heating mode and up in cooling mode.

Selecting the most appropriate temperature may prevent damage to the unit.

Do not expose your body directly to cold or hot air for a long time.

In the event of a malfunction (burning smell, etc.), switch off the air conditioner and switch off the circuit breaker.

Be careful not to disassemble, modify or move the device yourself. You may cause a fire, electric shock, or water leak.
If the cables are damaged, there is a risk of electric shock or fire. Always contact your dealer to repair or move the unit,

If a malfunction occurs (especially if there is a burning smell from the unit or the unit is no longer cooling), immediately
stop using the unit and turn off the circuit breaker. If you continue to use the product under these conditions, you may
be subjected to electric shock or fire. Always contact your dealer to repair or have the device inspected,

Do not connect the ground wire to a gas pipe, water pipe, lightning rod or to the telephone earth line.

If the drain hose of the indoor unit is exposed due to moving the unit, close the opening.

Do not touch the internal electrical components as this may result in electric shock or injury.

If the air conditioner does not cool or heat up, it is possible that refrigerant leakage has occurred. Contact your dealer.
The refrigerant used in the air conditioner is well protected. It will not leak under normal conditions of use. Nevertheless,
if a leak occurs and the fluid comes into contact with a heat source, especially with a radiator or a range, a harmful
reaction can take place.

Summary of Contents for OTEC ICHH Series

Page 1: ...High Wall Inverter Service Manual IEWH ICHH Series 220 240V 1 50Hz ...

Page 2: ...rating Instruction 3 Safety Instruction 6 2 SERVICE AND MAINTENANCE Clean the Front Panel and Remote Controller 13 Clean Air Filter 13 No Use for Long Time 14 Recommendations for Energy Saving 15 3 TROUBLESHOOTING Air Conditioner is in Error 16 Remote Controller is in Error 16 4 NORMAL PHENOMENONS 17 ...

Page 3: ...d containers aerosol cans If the unit is used in locations where ventilation is not available care must be taken to prevent refrigerant leakage which could result in a fire hazard Avoid installing the unit in a location where flammable gas leaks may occur A fire could start in case of gas leakage or gas accumulation around the unit Do not install it in an excessively humid place such as in a bathr...

Page 4: ... contact with water Electrical insulation could be damaged and cause a risk of electric shock Do not climb or place objects on the outdoor unit Never insert a stick or similar object into the outdoor unit You could be seriously injured WARNING The manufacturer declines all responsibility for damage caused by non observance of the safety instructions in this user manual Be careful not to install re...

Page 5: ...t is damaged If you do not perform this check and the table is damaged the unit may fall and injure someone Use a stable and sturdy ladder to install remove the front panel air filter Otherwise you risk to fall and injure yourself Do not hang on the outdoor unit and do not place any object on it This may indeed tip over or fall and you could hurt yourself Damage to the unit may cause electric shoc...

Page 6: ...eful of sharp edges on the front and rear fins of the unit that could cut and cause serious injury 7 Be careful when lifting the air conditioner to install or remove the unit Always use two or more people for this 8 Always cut off the power of air conditioner before servicing it or moving it 9 In some type of units there is no appropriate plug corresponding to its power cord because of power Under...

Page 7: ...f fire or electric shock otherwise Power specifications Installation environments Do not install air conditioner at the place where there is flammable or corrosive air Please confirm the following before installation Operating instruction Please operate air conditioner in accordance to this manual Caution Never install by yourself Split type air conditioner will work for you for a long period of t...

Page 8: ...ounded please contact an electrician to have it replaced with a properly grounded outlet or breaker Do not under any circumstances cut or remove the third ground prong from the power cord Adapter plug We strongly advise against using an adapter plug or breaker Operating conditions 1 Temperature T1 instance 7 45 16 45 in cooling only type T3 instance 7 52 16 52 in cooling only type If the unit runs...

Page 9: ...y for correct installation of the appliance including the minimum permissible distances to adjacent structures The appliance shall be installed in accordance with national wiring regulations Disconnect the power supply before cleaning and maintenance If the appliance is not connected by plug an all pole disconnection device which has at least 3mm separation distance in all pole and a residual curr...

Page 10: ...nditioner the running fan may cause injuries Do not put anything on the outdoor unit Do not switch on or off the unit by plugging or pulling off the plug or by switching on or off the breaker Keep indoor ventilated especially when there is operating gas equipment Do not substitute fuse with lead wire or other materials Pull off power plug or switch off breaker if the air conditioner is not used fo...

Page 11: ...ir conditioner s airflow Doing so could harm them Please contact service agents for service Improper service may cause accident Switch off the unit cut off the power source and make sure the fan stops before cleaning the unit For removal and installation of air conditioner please refer to professionals or contact service agents Warning The appliance is not intend for use by young children or infir...

Page 12: ...ith water or it may cause electric shock 2 Do not clean the remote controller with water 3 Do not clean with alcohol gasoline banana oil or polishing 4 Do not clean the unit violently or it may cause the front panel falling down 5 Do not clean the front panel or remote controller with metal brush it may damage the surface Clean Air Filter 1 Open the front panel Fig 4 2 Lift the protruding part the...

Page 13: ...ng Time 1 Swing 3 4 hours to dry the internal 2 Stop operation by remote controller then air conditioner cut off the power source of air conditioner 3 Maintain air filter net 4 Take out batteries from remote controller ...

Page 14: ...ind to obstruct direct sunlight Avoid Heat Sources When it is cooling using other heat sources may affect cooling effect Close Doors and Windows Incoming outdoor air will affect the cooling or heating efficiency Keep Air Filter Clean Keeping air filter clean ensures high efficiency operation Good Ventilation Do not put objects in front of the inlet and outlet of outdoor unit ...

Page 15: ...Check whether doors or windows are closed 5 Check whether fan speed or set temperature is improper Remote Controller is in Error The following trouble shooting is normal phenomenon Phenomenon Checking Items Fan stops or fan speed can not be controlled 1 When air conditioner is in DRY mode or SLEEP mode fan speed can t be controlled sometimes 2 When air conditioner is in COOL AIRFLOW PROOF or DEFRO...

Page 16: ...nd when the unit starts or stops It is the normal sound of flowing refrigerant Walls carpet furniture or clothes indoors may disseminate peculiar smell In order to protect the unit when the compressor stops there will be a 3 minute delay before restarting In the first several minutes of heating operation wind may not come out from the indoor unit Water may flow out from the outdoor unit during hea...

Page 17: ...OMEGAIEWH CHH High Wall Inverter Service Manual info otecomega com www otecomega com IEWH CHH I3A SM1C0622 info otecomega com www otecomega com ...