background image

WARRANTY

OMEGA warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a
period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the
normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA's customers
receive maximum coverage on each product. If the unit should malfunction, it must be returned to the factory for
evaluation. OMEGA's Customer Service Department will issue an Authorized Return (AR) number immediately
upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or
replaced at no charge. However, this WARRANTY is VOID if the unit shows evidence of having been tampered with
or shows evidence of being damaged as a result of excessive corrosion; or current, heat moisture or vibration;
improper specification; misapplication; misuse or other operating conditions outside of OMEGA's control. Components
which wear or which are damaged by misuse are not warranted. This includes contact points, fuses, and triacs.

OMEGA is glad to offer suggestions on the of use of its various products. Nevertheless, OMEGA only warrants
that the parts manufactured by it will be as specified and free of defects

OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER,
EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY
WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY
DISCLAIMED.

LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of
OMEGA with respect to this order, whether based on  contract warranty, negligence, indemnification, strict
liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In
no event shall OMEGA be liable for consequential, incidental or special damages.

Every precaution for accuracy has been taken in the preparation of this manual; however, OMEGA ENGINEERING,
INC. neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages
that result from the use of the products in accordance with the information contained in the manual.

SPECIAL CONDITION: Should this equipment be used in or with any nuclear installation or activity, purchaser will
indemnity OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the
equipment in such a manner.

Summary of Contents for OS641C-MV-LS

Page 1: ...OS641C MV LS Infrared Temperature Transducer With Laser Marker OMEGA ...

Page 2: ... info omega com e mail info omega com Servicing Europe Benelux Postbus 8034 1180 LA Amstelveen The Netherlands Tel 31 20 6418405 FAX 31 20 6434643 Toll Free in Benelux 06 0993344 e mail nl omega com Czech Republic ul Rude armady 1868 733 01 Karvina Hranice Czech Repubic Tel 420 69 6311627 FAX 420 69 6311114 e mail czech omega com France 9 rue Denis Papin 78190 Trappes Tel 33 130 621 400 FAX 33 130...

Page 3: ... must refer to an explanation in this manual 1 DANGER Pressing the button turns the laser marker on and off Exercise extreme care and do not allow the laser beam to enter your eye or those of any other person or animal Do not look directly into the laser light from the optical system When measuring the temperature of an object which has a mirror finish be careful not to allow the laser light beam ...

Page 4: ...thesensor may be damaged Do not contact the lens against the object whose temperature is to be measured or get it dirty allow it to be scratched or allow any foreign material to adhere to it Doing so may cause errors Do not touch or hold by the front cone Temperature reading can be affected by heat from hand Do not place the meter on or around hot objects 70 C 158 F It may cause damage to the case...

Page 5: ...rating level Operating Environment 0 C to 50 C at 70 relative humidity Storage Temperature 20 C to 60 C 0 to 80 R H with battery removed from meter Battery 4 pcs 1 5V AAA size Battery Life 100 hours continuity typical Laser marker not illuminated Dimensions 170mm H x 44mm W x 40mm D Weight 200g including batteries 3 ...

Page 6: ...erature Coefficent 0 2 of reading or 0 2 C whichever is greater change in accuracy per C change in ambient operating temperature above 28 C or below 18 C Response Time 1 second Spectral Response 6 to 14µm nominal Emissivity Pre set 0 95 Detection Element Thermopile Optical Lens Fresnal Lens Sighting 1 beam laser marker 1mW class 2 Field of View 65mmØ at 1000mm ...

Page 7: ...he probe tip as shown CAUTION Use of controls or Adjustments or performance of Procedures other than those Specified herein may result in Hazardous radiation exposure Aperture Label on front Danger Certification ID Label Located on back of unit ...

Page 8: ...n and turn off the Laser Marker annunciator If annunciator turn on press MEAS button the laser marker beam is being emitted releasing MEAS button turn off the laser marker beam MEAS MEASURE Button Depress MEAS button to turn on the meter for temperature measurement Release the MEAS button to stop temperature measurement ...

Page 9: ... the MEAS button Measurement is performed as long as the MEAS button is kept pressed 6 Referring to the spot size figure aim the laser beam at the object whose temperature is to be measured NOTE Although the field of measurement or Field of View and the spot almost coincide actually the field of measurement corresponds to the diameter for 90 optical response The object whose temperature is to be m...

Page 10: ...orbed by solid matter With an emission thermometer which operates by detecting infrared radiation accurate measurement is possible irrespective of the air tempera ture or the measrement distance 3 Emission Thermometer Structure Infrared radiation which has been emitted from the object is focused upon an infrared radiation sensor via an optical system which includes a lens is transparent to infrare...

Page 11: ...y reflective object to 1 00 for a black body Factory set emissivity value of 0 95 which cover 90 of typical applications 5 If the surface to be measured is covered by frost or other material clean it to expose the surface 6 If the surface to be measured is highly reflective apply masking tape or matt finish black paint to the surface 7 If the meter seems to be giving incorrect readings check the f...

Page 12: ...ATT red LED lighted when replacement is needed To replace the batteries remove the screw from the back of the meter and lift off the battery cover case Remove the batteries from battery contacts Cleaning Periodically wipe the case with a damp cloth and detergent do not use abrasives or solvents ...

Page 13: ...wder 0 96 Earth 0 92 to 0 96 Lacquer 0 80 to 0 95 Water 0 92 to 0 96 Lacquer matt 0 97 Ice 0 96 to 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 85 to 0 95 Glass 0 90 to 0 95 Timber 0 90 Ceramic 0 90 to 0 94 Paper 0 70 to 0 94 Marble 0 94 chromium oxides 0 81 Plaster 0 80 to 0 90 Copper oxides 0 78 Mortar 0 89 to 0 91 lron oxides 0 78 to 0 82 Brick red 0 93 to 0 96 Textiles 0 90 11 ...

Page 14: ... use of its various products Nevertheless OMEGA only warrants that the parts manufactured by it will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIABI...

Page 15: ...pondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have the following information available BEFORE contacting OMEGA 1 P O number under which the product was PURCHASED 2 Model and serial number of the product under warranty and 3 Repair instructions and or specific problems relative to the prod...

Page 16: ...Probes Connectors Panels Assemblies þ Wire Thermocouple RTD Thermistor þ Calibrators Ice Point References þ Recorders Controllers Process Monitors þ Infrared Pyrometers ENVIRONMENTAL MONITORING AND CONTROL þ Metering Control Instrumentation þ Refractometers þ Pumps Tubing þ Air Soil Water Monitors þ Industrial Water Wastewater Treatment þ pH Conductivity Dissolved Oxygen Instruments pH CONDUCTIVIT...

Reviews: