Ref.No.

042011 

OS499L-30

(with white LED Flashlight) 

Thermometer Operating Instructions 

For Model with thermocouple socket 

The  thermometer  is  a  non-contact  infrared  thermometer.  There  are  many  mathematical  modes  for  the  Infrared  function.  Please 

remember to keep away from children and don’t use it for safety related applications. 

(Default Screen)

 

Simply aim the 

thermometer at the 

measure target 
with Lens (

7

7

) and 

press Meas. key 
(

6

) to display the 

surface 

temperature. The 

Distance:Spot is 30:1. Please make sure the target area is within the field of view. 

FUNCTION   

Press Mode key ( ) for scrolling more display function as follows.

 

 

Here will show the emissivity data. (The default emissivity is 0.95.) 

 

Press Mode key ( ) , then press Up key (

4

2

2

4

6

3

5

4

3

3

2

) or Down key ( ) to

 set the emissivity

, then press Mode key ( ) 

to confirm it. The emissivity can be changed from 0.10 (10E) to 1 (100E). 

 

 
 
 

Press  Mode  key  ( )  for  the

  Maximum  (MAX),  Minimum  (MIN),  Different  between  MAX  and  MIN  (DIF)  and 

Average (AVG) modes. During the measurement, the special modes reading will be displayed beside the 
mode icon.

 

 
 

Press Up key ( ) or Down key ( ) key to change the

 High Alarm (HAL) 

or

 Lo Alarm (LAL)

, then press Meas. 

key ( ) to confirm it. When the reading is outside the 

High Alarm (HAL)

 or 

Lo Alarm (LAL)

 limit. The High or 

Low icon will flash and you will hear a beep sound. 

 

Connect the thermocouple with Thermocouple socket ( ) and put the probe in/on the target, the thermometer will 

display the temperature automatically without pressing any button. To see the minimum or maximum data during 

the probe measurement, please hold down the Up key ( ) or Down key ( ). 

  After measure high temp, the probe may remain HOT for a while. 

** The thermometer will automatically shut off if left idle for more than 60sec, unless in PRB mode. (In PRB mode, it will shut off if 

left idle for more than 12 minutes.) 

ADD VALUE 

Press  Up  key  ( )  for 

LOCK  mode

  ON/OFF.

   

The  lock  mode  is  particularly  useful  for  continuous 

monitoring of temperatures for up to 60 minutes.

 

In E, MAX, MIN, DIF, AVG 
mode: 

Press Down key ( ) for

 

o

or

 

o

F transferred. 

In MAX, MIN mode: Hold 
on the Meas. key ( ) 

The Bar display indicates the measuring temperature.   

The bar shows 

RED

 color when the reading is close to 

maximum value, and shows 

BLUE

 when close to 

minimum. While the temperature is between the maximum 

and minimum, the bar will display in 

YELLOW

.   

     

 

 

Backlight   

LCD Backlight: always on. 

 

In  all  modes:  First  hold 
on the Meas. key ( )

 

and press Down key ( ) for

 laser function

 ON/OFF.   

 

CAUTION 

1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE LASER BEAM–PERMANENT EYE DAMAGE MAY RESULT. 

2. USE EXTREME CAUTION WHEN OPERATING THE LASER. 

3. NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.   
4.

KEEP OUT OF REACH OF ALL CHILDREN. 

STORAGE & CLEANING       

It should be stored at room temperature. The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times, 
care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol, allowing the lens to fully dry 
before using the thermometer. Do not submerge any part of the thermometer. 

LCD ERROR MESSAGES 

The thermometer incorporates visual diagnostic messages as follows: 

 

‘Hi’

 or

 ’Low’

 is displayed when the temperature being measured is outside of the settings of HAL and LAL. 

 

‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature. ‘Er3’ is 
displayed when the ambient temperature exceeds 0

o

C (32°F) or +50

o

C (122°F). The thermometer should 

be allowed plenty of time (minimum 30 minutes) to stabilize to the working/room temperature. 

 

Error  5~9

,  for  all  other  error  messages  it  is  necessary  to  reset  the  thermometer.  To  reset  it,  turn  the 

instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and turn on. 
If the error message remains please contact the Service Department for further assistance. 

 

‘Hi’ or ’Lo’ is displayed when the temperature being measured is outside of the measurement range.

 

BATTERIES

 

The thermometer incorporates visual low battery indication as follows: 

 

 

 

‘Battery OK’: measurements 

  are possible 

‘Battery Low’: battery needs to be   

replaced, measurements are still possible 

‘Battery Exhausted’: measurements are not 

possible 

  When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AAA, 1.5V batteries. Please note: It 

is important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction. 

  Dispose of used battery promptly and keep away from children. 

SPECIFICATION 

 

m

e

tI

Thermocouple Probe Scan function 

(K type; probe not included.) 

Measurement Range 

-60 to +760

 o

C (-76 to +1400

 o

F) 

-64 to +1400°C (-83.2 to +2552°F) 

Operating Range 

0 to +50°C (32 to +122°F) 

Accuracy (Tobj=15~35°C, Tamb=25°C) 

Accuracy(Tamb=23±3°C) 

+/-1% of reading or 1°C (1.8°F) whichever is greater

 

(Test under Tamb=23±6°C) 

Emissivity Range 

0.95 default – adjustable 0.1 to 1 step .01 

 

F

°

1

/

C

°

1

 

e

s

i

w

r

e

h

t

o

 ,

)

F

°/

C

°

(

9

.

9

9

9

 

o

2

.

3

8

t

a

 

F

°

1

.

0

/

C

°

1

.

0

 

 

n

o

it

u

l

o

s

e

R
Response Time (90%) 

1sec 

Distance:Spot 

30:1(90% energy covered) 

Battery Life(Alkaline) 

Min. 30 hours continuous use without laser 

Min. 7 hours continuous use with laser   

Min. 3 hours continuous use with laser and white LED(TN499LCE) 

 )

h

c

n

6

7

.

6

×

7

8

.

1

×

7

.

4

m

m

 

8

.

1

7

1

*

5

.

7

4

*

2

.

9

1

1

 

s

n

o

i

s

n

e

m

i

D

 )

s

c

p

2

*

A

A

A

s

e

ir

e

tt

a

b

 

g

n

i

d

u

l

c

n

)

z

o

 

2

0

.

9

(

s

m

a

r

g

 

7

.

5

5

2

 t

h

g

i

e

W
Note: Under the electromagnetic field of 3V/m from 200 to 600 MHz, the maximum error is 10

 o

C (18

 o

F). 

  Caution: The measure range is for thermometer only. User should choose proper probe types for different kinds of application. 

      Please make sure the  target  to be measured will not exceed the temperature  range of the probe to avoid  permanent damage of 

the thermocouple probe. 

  Caution: To avoid electric shock and thermometer damage, do not measure live circuit where voltage exceeding 24V AC RMS or   

      60V DC  with the thermocouple probe. 

 

EMC/RFI: 

Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per 

      meter, but the performance of the instrument will not be permanently affected.

 

*Dual laser 
points specify 
the approximate 
measurement 
area for better 
targeting.

 

2

4

3

3

6

6

Reviews: