Page 1: ...e mail info omega com For latest product manuals omegamanual info Shop online at omega comSM User sGuide OS MINIUSB SERIES...

Page 2: ...notice Servicing North America U S A Omega Engineering Inc One Omega Drive P O Box 4047 Stamford CT 06907 0047 USA Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Canada o...

Page 3: ...21 20 1 OS MINIUSB SN201 Interface USB Accuracy 1 of reading or 1 C whichever is greater Repeatability 0 5 of reading or 0 5 C whichever is greater Emissivity 0 2 to 1 0 Response Time t90 125 ms 90 re...

Page 4: ...collar Laser sighting tool OPTIONS An optional certificate of calibration is available for newly manufactured sensors If required it must be ordered at the same time as the sensor OPTICAL CHART The op...

Page 5: ...CE To minimise electromagnetic interference or noise the sensor should be mounted away from motors generators and such like MECHANICAL INSTALLATION All sensors come with a 1 5 m USB cable and a mounti...

Page 6: ...ntil the software has been fully installed The software will tell you when to connect the sensor This will ensure the USB driver for the sensor is installed properly 1 Insert the provided CD or downlo...

Page 7: ...ivity setting should match the actual emissivity of the target surface Non reflective non metals such as rubber foods thick plastics organic materials and painted surfaces generally have a high emissi...

Page 8: ...Status bits active high Bit 0 Measurement error Bit 1 Sensor temperature low Bit 2 Sensor temperature high Bit 3 Object temperature low Bit 4 Object temperature high R 0x16 1 Reflected Temperature no...

Page 9: ...with Windows Vista 7 8 or 10 Erroneous temperature Field of view obstruction Remove obstruction LENS CLEANING Keep the lens clean at all times Any foreign matter on the lens would affect measurement a...

Page 10: ...8...

Page 11: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 12: ...ity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial...