Cleaning 

Safety Precaution 

Before cleaning your rangehood or performing any maintenance, please ensure that the range hood is 

turned off at the power point. 
Do not use abrasive cleaners to clean the range hood. The use of warm soapy water and a cloth are 

recommended. 
Ensure that the range hood is cleaned regularly, as a build-up of grease and fat may occur otherwise. 
The filters on the range hood must be cleaned regularly to maintain efficiency, and prevent grease build up. 

The filter mesh is made of metal. It is recommended that this is undertaken every 4 – 6 weeks, depending 

on frequency of use. The filters can be cleaned with warm soapy water or a cloth. 
Cleaning of the range hood must be performed as described above; otherwise there is a possibility of a fire 

hazard due to grease and fat build up. 

Replacing the Lamp 

WARNING

: Before changing the lights, make sure that the appliance is unplugged from the power source 

and that the lamps are cool. 

1) 

Open the filter and twist the face of the lamp anti-clockwise to disengage the lamp. 

2) 

Change the 2W LED lamp with an identical lamp: 

a. 

Max Wattage: 2 x 2W 

b. 

Voltage Range: 220 – 240V AC 

c. 

ILCOS D Code: DBS-2/65-H-120/33 

3) 

Replace the filter to the original position. 

 

 

 

 

 

 

 

Installation Instructions 

Method two (Mounting under a Cupboard): 

1) 

The rangehood must be placed at a minimum distance of 65cm from the cooking surface. The 

maximum distance should be 75cm for the best effect Drill 4 holes of Ø 6mm at the bottom of the 

hanging cupboard. 

2) 

Drill six Ø4mm holes at the bottom of the cupboard. Cut a minimum Ø120mm hole for the outlet 

venting (if required). 

3) 

Put the one-way valve on the rangehood (if required), then install the rangehood onto the bottom 

of the cupboard, tighten the hood with enclosed 6 screws (M4*35mm). 

4) 

Install the adjusted board on the bottom of the hood in order to keep out the gap between hood 

back and cupboard. 

 

Recirculating or Ducted Venting: 

The rangehood can be installed to vent the exhaust fumes out of the room (ducted) or to recirculate the air 

back into the room once it has been filtered (recirculating). To set the rangehood up to vent the exhaust 

fumes out of the room, adjust the venting switches (internal between the fans) to ducted and connect 

appropriate ducting to the one way valve. 

To set the rangehood up to vent back into the room, remove the vent cover from the front of the rangehood 

and adjust the venting switch to recirculating. Note that carbon filters must also be fitted to the fan inlets as 

shown. 

 

Operating Instructions 

The controls are at the bottom front of the rangehood. 

LIGHT CONTROLS: 

Use switch 1 to turn the lights on (I) or off (0). 

SPEED ADJUSTMENT: 

Use switch 2 to adjust the fan speed from low (I) to high (III), and turn off (0). 

NOTE

: Always fully extend the slide-out when in use. 

 

 

Summary of Contents for ORT6WBA

Page 1: ...Instruction Manual OMEGA RANGEHOOD ORT6WBA...

Page 2: ...nd easy recipes follow us on our socials facebook com omegaappliances instagram com omegaappliances_aus Thank you for purchasing an Omega appliance Tailored for the modern aesthetic and lifestyle of b...

Page 3: ...you retain these instructions proof of purchase as well as other important documents about this product for future reference The manufacturer will not be responsible for any damage to property or to p...

Page 4: ...g 13 It is recommended to leave the range hood in operation for 15 minutes after cooking is terminated in order to completely eliminate cooking vapours and odours 14 Turn off the range hood when not i...

Page 5: ...Mounting to a wall 1 The range hood must be placed at a minimum distance of 65cm from the cooking surface The maximum distance should be 75cm for the best effect 2 To install onto the wall drill 2 ho...

Page 6: ...Ducted Venting The rangehood can be installed to vent the exhaust fumes out of the room ducted or to recirculate the air back into the room once it has been filtered recirculating To set the rangehoo...

Page 7: ...al It is recommended that this is undertaken every 4 6 weeks depending on frequency of use The filters can be cleaned with warm soapy water or a cloth Cleaning of the range hood must be performed as d...

Page 8: ...t Switch power outlet on Oil leakage One way valve and the air ventilation entrance are not tightly sealed Take down the one way valve and seal with sealant Leakage from the connection of U shaped sec...

Page 9: ...l It is recommended that this is undertaken every 4 6 weeks depending on frequency of use The filters can be cleaned with warm soapy water or a cloth Cleaning of the range hood must be performed as de...

Page 10: ...service without special equipment and subject to these terms and conditions repair or replace any parts which it considers to be defective Residentia Group or its ASR may use remanufactured parts to r...

Page 11: ...and off the cooktop surface and not dragged Cooking zones should not be switched on without cookware placed on it Do not place empty cookware onto the cooking zones when in use 21 If any cracking is n...

Page 12: ...1...

Reviews: