Table 21. Digital I/O connector (J33) pinout 

Pin  Signal Name 

Pin Description 

Pin 

Signal Name 

Pin Description 

DOUT0 

Digital Output 0/ Alarm Output 0 

DOUT1 

Digital Output 1/ Alarm Output 1 

DOUT2 

Digital Output 2/ Alarm Output 2 

DOUT3 

Digital Output 3/ Alarm Output 3 

DOUT4 

Digital Output 4/ Alarm Output 4 

DOUT5 

Digital Output 5/ Alarm Output 5 

DOUT6 

Digital Output 6/ Alarm Output 6 

DOUT7 

Digital Output 7/ Alarm Output 7 

DOUT8 

Digital Output 8/ Alarm Output 8 

10 

DOUT9 

Digital Output 9/ Alarm Output 9 

11 

DOUT10 

Digital Output 10/ Alarm Output 10 

12 

DOUT11 

Digital Output 11/ Alarm Output 11 

13 

DOUT12 

Digital Output 12/ Alarm Output 12 

14 

DOUT13 

Digital Output 13/ Alarm Output 13 

15 

DOUT14 

Digital Output 14/ Alarm Output 14 

16 

DOUT15 

Digital Output 15/ Alarm Output 15 

17 

IGND 

Isolated Digital GND 

18 

IGND 

Isolated Digital GND 

19 

IGND 

Isolated Digital GND 

20 

IGND 

Isolated Digital GND 

21 

DOUT16 

Digital Output 16/ Alarm Output 16 

22 

DOUT17 

Digital Output 17 / Alarm Output 17 

23 

DOUT18 

Digital Output 18/ Alarm Output 18 

24 

DOUT19 

Digital Output 19/ Alarm Output 19 

25 

DOUT20 

Digital Output 20/ Alarm Output 20 

26 

DOUT21 

Digital Output 21/ Alarm Output 21 

27 

DOUT22 

Digital Output 22/ Alarm Output 22 

28 

DOUT23 

Digital Output 23/ Alarm Output 23 

29 

DOUT24 

Digital Output 24/ Alarm Output 24 

30 

DOUT25 

Digital Output 25 / Alarm Output 25 

31 

DOUT26 

Digital Output 26/ Alarm Output 26 

32 

DOUT27 

Digital Output 27/ Alarm Output 27 

33 

DOUT28 

Digital Output 28/ Alarm Output 28 

34 

DOUT29 

Digital Output 29/ Alarm Output 29 

35 

DOUT30 

Digital Output 30/ Alarm Output 30 

36 

DOUT31 

Digital Output 31/ Alarm Output 31 

37 

IGND 

Isolated Digital GND 

38 

IGND 

Isolated Digital GND 

39 

IGND 

Isolated Digital GND 

40 

IGND 

Isolated Digital GND 

41 

DIN0 

Digital Input 0 

42 

DIN1 

Digital Input 1 

43 

DIN2 

Digital Input 2 

44 

DIN3 

Digital Input 3 

45 

DIN4 

Digital Input 4 

46 

DIN5 

Digital Input 5 

47 

DIN6 

Digital Input 6 

48 

DIN7 

Digital Input 7 

49 

IGND 

Isolated Digital GND 

50 

IGND 

Isolated Digital GND 

Table 22. Expansion connector (J34) pinout 

Pin  Signal Name 

Pin Description 

Pin 

Signal Name 

Pin Description 

+12VA (Note) 

+12 VA power output 

Note 8 

AGND 

Isolated Analog GND 

+12VA 

+12 VA power output 

AGND 

Isolated Analog GND 

+5VA 

+5 VA power output 

AGND 

Isolated Analog GND 

+5VA 

+5 VA power output 

AGND 

Isolated Analog GND 

+5VA 

+5 VA power output 

10 

AGND 

Isolated Analog GND 

11 

+5VA 

+5 VA power output 

12 

AGND 

Isolated Analog GND 

13 

+3.3VA 

+3.3 VA power output 

14 

AGND 

Isolated Analog GND 

15 

+3.3VA 

+3.3 VA power output 

16 

AGND 

Isolated Analog GND 

17 

+3.3VA 

+3.3 VA power output 

18 

AGND 

Isolated Analog GND 

19 

+3.3VA 

+3.3 VA power output 

20 

AGND 

Isolated Analog GND 

21 

CS 

Chip select 

22 

AGND 

Isolated Analog GND 

23 

SCK 

Serial clock 

24 

AGND 

Isolated Analog GND 

25 

MOSI 

Master output data 

26 

AGND 

Isolated Analog GND 

27 

MISO 

Master input data 

28 

AGND 

Isolated Analog GND 

29 

IRQ 

Interrupt request 

30 

AGND 

Isolated Analog GND 

31 

RSVD 

Reserved 

32 

AGND 

Isolated Analog GND 

33 

RSVD 

Reserved 

34 

AGND 

Isolated Analog GND 

35 

RSVD 

Reserved 

36 

AGND 

Isolated Analog GND 

37 

RSVD 

Reserved 

38 

AGND 

Isolated Analog GND 

39 

EXP_DETECT 

EXP detection 

40 

AGND 

Isolated Analog GND 

Note 8:  

Power supplies (+12 VA, +5 VA, 3.3 VA) located at connector J34 are intended for use with the  
OMB-DAQ-TC-RACK-EXP32 expansion device only.   

Summary of Contents for OMB-DAQ-TC-RACK

Page 1: ...e mail info omega com For latest product manuals www omegamanual info OMB DAQ TC RACK 32 Channel USB Ethernet Based Thermocouple Input Data Acquisition System Shop online at omega comSM User sGuide...

Page 2: ...SA Canada only Engineering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide omega com info omega com The inf...

Page 3: ...the OMB DAQ TC RACK for communication across networks 10 Calibrating the hardware 10 Factory calibration 10 Field calibration 10 Restoring factory default network settings 10 Chapter 3 Functional Det...

Page 4: ...4 Power 23 USB 24 Network 24 Ethernet connection 24 Network interface 24 Network factory default settings 25 Network security 25 LED displays and the factory reset button 25 Environment 25 Mechanical...

Page 5: ...ation to help you avoid injuring yourself and others damaging your hardware or losing your data bold text Bold text is used for the names of objects on a screen such as buttons text boxes and check bo...

Page 6: ...ector USB 2 0 or 10 100 Ethernet interface Powered by the included 5 V external power adapter OMB DAQ TC RACK PS Ethernet interface The OMB DAQ TC RACK has a built in 10 100 BASE T auto negotiation hi...

Page 7: ...MB DAQ TC RACK User s Guide Introducing the OMB DAQ TC RACK 7 Functional block diagram Device functions are illustrated in the block diagram shown here Figure 1 OMB DAQ TC RACK functional block diagra...

Page 8: ...provided to a to a USB port on a computer running Windows Windows finds and installs the device driver automatically and notifies you that the device is ready to use Installing on Ethernet The OMB DAQ...

Page 9: ...ortly after it is powered up and attached to the network Link Local Only The OMB DAQ TC RACK is assigned a link local IP address by the Windows PC or other host that supports link local addressing A l...

Page 10: ...on The Omega Engineering Manufacturing Test department performs the initial factory calibration Return the device to Omega Engineering when calibration is required The recommended calibration interval...

Page 11: ...nnector Figure 3 OMB DAQ TC RACK rear panel components USB connector The USB connector provides USB communication Ethernet connector The OMB DAQ TC RACK has one 10 100 BASE T auto negotiation high spe...

Page 12: ...e voltage is calculated as follows 11 4 V 10 V 8 6 V 3 10 V Each TC channel becomes biased to the average common mode voltage of 10 V Each common mode voltage must then be within the 10 V 1 4 V limits...

Page 13: ...cause an error voltage to develop across the lead resistance of the TC that is indistinguishable from the thermocouple voltage you are measuring You can estimate this error voltage with the following...

Page 14: ...an also use the alarm outputs to control a device or application that indicates when a temperature threshold has been exceeded When its pull up is disabled a DO bit can be used to control a device nee...

Page 15: ...output line can be used for normal operation Alarm enabled active low output output line goes low when alarm condition is met Alarm enabled active high output output line goes high when alarm conditi...

Page 16: ...arately for applications that need additional analog thermocouple input and digital I O channels A 40 pin expansion cable is included with the OMB DAQ TC RACK EXP32 Chassis ground connector Provides a...

Page 17: ...OMB DAQ TC RACK User s Guide Functional Details 17 Mechanical drawings Figure 8 Enclosure dimensions front Figure 9 Enclosure dimensions rear...

Page 18: ...OMB DAQ TC RACK User s Guide Functional Details 18 Figure 10 Enclosure dimensions side Figure 11 Circuit board dimensions...

Page 19: ...nput current Open thermocouple detect disabled 2 nA Open thermocouple detect enabled 75 nA Common mode rejection 50 Hz filtering at DC and fin 50 Hz 110 dB 60 Hz filtering at DC and fin 60 Hz 110 dB N...

Page 20: ...d CMVaverage 1 4 V Note 3 Measurement sensitivity is the smallest change in temperature that can be detected Channel configuration Table 2 Channel configuration specification Sensor Category Condition...

Page 21: ...1 254 700 0 937 0 424 1 136 0 520 1820 0 610 0 300 1 056 0 467 E 200 1 754 0 811 1 933 0 880 0 0 775 0 355 0 806 0 369 1000 0 657 0 323 0 989 0 437 T 200 2 005 0 923 2 207 1 005 0 0 836 0 382 0 874 0...

Page 22: ...e 1 5 V max 0 6 V min Schmitt trigger hysteresis 0 4 V min 1 2 V max Table 6 Digital output specifications Parameter Specification Number of outputs 32 channels shared with alarms Configuration Open d...

Page 23: ...t output line goes high when alarm condition is met Enabled active low output output line goes low when alarm condition is met Alarm output may be latched and will not clear unless explicitly cleared...

Page 24: ...Self powered no USB current consumed Network Ethernet connection Table 12 Ethernet connection specifications Parameter Specification Ethernet type 100 Base TX 10 Base T Communication rates 10 100 Mbps...

Page 25: ...fication POWER LED top Indicates power on Blinks when blink command is sent Both the POWER and ACTIVITY LEDs blink in firmware upgrade mode ACTIVITY LED On when there is a valid connection and blinks...

Page 26: ...r input J4 TC3 CH3 sensor input J20 TC19 CH19 sensor input TC3 CH3 sensor input TC19 CH19 sensor input J5 TC4 CH4 sensor input J21 TC20 CH20 sensor input TC4 CH4 sensor input TC20 CH20 sensor input J6...

Page 27: ...29 35 DOUT30 Digital Output 30 Alarm Output 30 36 DOUT31 Digital Output 31 Alarm Output 31 37 IGND Isolated Digital GND 38 IGND Isolated Digital GND 39 IGND Isolated Digital GND 40 IGND Isolated Digi...

Page 28: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 29: ...bine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industri...

Reviews: