OMEGA ENGINEERING, INC., warrants this unit to be free of defects in materials and workmanship for a period 

of  61 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the 

normal  five (5) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers 

receive maximum coverage on each product. 

If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department 

will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by 

OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does 

not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper 

interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is 

VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a 

result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse 

or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but 

are not limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes 

responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its 

products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only 

that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER 

WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT 

OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser 

set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on 

contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price 

of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental 

or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” 

under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used 

on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, 

used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/

DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any 

liability or damage whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURN-

ING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM 

OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR 

number should then be marked on the outside of the return package and on any correspondence. The purchaser is 

responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following  

information available BEFORE contacting OMEGA.

1.  Purchase order number which the product 

 

was PURCHASED,

2.  Model and serial number of the product  

 

under warranty, and

3.  Repair instructions and/or specific problems 

 

relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords 

customers the latest technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC.

© COPYRIGHT 2013 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, 

translated, or reduced to any electronic medium-readable form, in whole or in part, without the prior written consent of 

OMEGA ENGINEERING, INC.

FOR NON-WARRANTY RETURNS, consult OMEGA 

for current repair charges. Have the following 

information available BEFORE contacting OMEGA.

1.  Purchase Order number to cover the COST of the  

 repair,

2.  Model and serial number of the product and
3.  Repair instructions and/or specific problems 

 

relative to the product.

Summary of Contents for OM-ES-020

Page 1: ...OM ES 020 Ethernet to Serial Device Server Shoponlineat omega com e mail info omega com For latest product manuals omegamanual info QUICK START...

Page 2: ...epublic Frystatska 184 733 01 Karvin Czech Republic TEL 420 59 6311899 FAX 420 59 6311114 e mail info omegashop cz France Toll Free 0805 541 038 TEL 01 57 32 48 17 FAX 01 57 32 48 18 e mail esales ome...

Page 3: ...our OM ES 020 Device on Windows 7 6 Configuring your OM ES 020 Device 10 7 Default Settings 11 8 Pin outs 12 9 LED information 13 For more information please refer to Product Manual on CD Information...

Page 4: ...EGA ENGINEERING INC Utility Software for OM ES Series Ethernet to Serial Device Servers Includes Software User Manuals Rev _____ Product CD Thank you for purchasing an OM ES 020 Ethernet to Serial pro...

Page 5: ...use unfolded pa perclip to press 2 Wall mount screw hole 7 Ethernet port connection 10BaseT 100BaseTX 3 Serial Port LED 8 Status LED 4 Ethernet LED 9 DIN Rail kit holes 5 Power Input 5 30V DC 0 75 1...

Page 6: ...to the OM ES 020 device If no DHCP Server is detected e g you are using a direct cable connection to the PC the OM ES 020 device will default to an IP address of 192 168 127 254 within 60 seconds Ple...

Page 7: ...or jack connection If using your own power supply please check input requirements on page 5 Hardware 3 When the Status LED turns steady green after 5 60 seconds the device is ready to use 4 Connect t...

Page 8: ...k the CD and select Explore This will open the CD in Windows Explorer for browsing the contents of the CD Locate the Setup exe program on the CD and double click to launch Proceed to Step 3 Note If in...

Page 9: ...left hand side of the window 3 Follow the on screen instructions to install the Boost LAN software Note Boost LAN software requires the Microsoft NET framework to be installed on your machine If it is...

Page 10: ...on the left hand panel 6 You can find your Omega OM ES 020 device by selecting a device and matching it with the corresponding MAC address available on the left hand panel 8 Click Install Device 9 Whe...

Page 11: ...ers and the firewall exceptions Program Name Default Port Number Device Web Server 80 Serial Port 1 9001 Serial Port 2 9002 Firmware Upgrade 67 BOOTP Server 68 BOOTP Client 69 TFTP Port Default Window...

Page 12: ...15200 Databits 8 Stop Bits n Parity 1 Flow Control None Duplex Mode N A Protocol Settings Telnet COM port control Mode Server TCP UDP Port Numbers Device Web Server 80 TCP Serial Ports 1 8 9001 9008 T...

Page 13: ...al Block Pin outs Power Terminal Block Pin outs OM ES 020 Pin 1 TxD Pin 2 RxD Pin 3 RTS Pin 4 CTS Pin 5 GND Pin 6 DTR Pin 7 DSR Pin 8 DCD Pin 9 RI Pin 10 GND Pin 1 V Power Supply Pin 2 V Power Supply...

Page 14: ...ed Performing Hard Reset Flashing between Green Yellow Problem during initialization e g Firmware Problem Serial Port LED Green light on Port Open Flashing light on Data RX TX Ethernet LED Green light...

Page 15: ...ct liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITION...

Page 16: ...rs Turbine Paddlewheel Systems Totalizers Batch Controllers PH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conducti...